The present work aims to study the efficiency of using aluminum refuse, which is available locally (after dissolving it in sodium hydroxide), with different coagulants like alum [Al2 (SO4)3.18H2O], Ferric chloride FeCl3 and polyaluminum chloride (PACl) to improve the quality of water. The results showed that using this coagulant in the flocculation process gave high results in the removal of turbidity as well as improving the quality of water by precipitating a great deal of ions causing hardness. From the experimental results of the Jar test, the optimum alum dosages are (25, 50 and 70 ppm), ferric chloride dosages are (15, 40 and 60 ppm) and polyaluminum chloride dosages were (10, 35 and 55 ppm) for initial water turbidity (100, 500 and 1000 NTU) respectively. While, adding sodium aluminate with the coagulants (Alum, FeCl3 and PACl), the optimum dose of 50 ppm was enough for the reduction of turbidity and hardness of water.
As Alkaloids known for their pharmaceutical importance; this research included the extraction of crude alkaloids of three plants (Zingiber officinale Roscoe., Thymus vulgaris L. and Acacia arabica L.) and evaluate their activity as coagulant agent by using three degraded concentrations of each plant extract and tested them on lab mice through the observation of the variations in bleeding time (BT), clotting time (CT) and platelet count. The results revealed differences in the percentage of alkaloids in the plants under the study; Z. officinale extract was the higher one followed by T. vulgaris and A. arabica respectively. Z. officinale extract was also the most effective plant as coagulant factor than other two plants as it decreased bot
... Show MoreThe aqueous extract of milk thistle (Silybum marianum) leaves as a green corrosion inhibitor for AA7051 aluminum alloy in sodium hydroxide solution was investigated at a range of temperatures. Potentiodynamic polarization findings exhibit a mixed–type inhibitor with directly increased inhibition efficiency with the concentration of inhibitor. The adsorption of the inhibitor on aluminum alloy obeys Langmuir isotherm and the kinetic as well as thermodynamic parameters were measured and discussed.
The operative system of theatrical performance depends on the construction of the scenographic space, as it constitutes the most aesthetic effect of the recipient, and the body of the theatrical discourse that contains the signs of the show, and it comes as an embodiment of the directing vision of the show director, so most of the world directors resorted to attention to the output treatment to establish the scenographic space, and thus it possesses a contrast in The embodiment of the directing vision according to the stylistic and hermeneutical dimension of the director, so the two researchers found the importance of studying the topic, and the study came under the title (Directing Treatments of the Scenographic Space in the Iraqi Theat
... Show MoreIn many industries especially oil companies in Iraq consumed large quantities of water which will produce oil-contaminated water which can cause major pollution in agricultural lands and rivers. The aim of the present work is to enhance the efficiency of dispersed air flotation technique by using highly effective and cost-efficient coagulant to treating gas oil emulsion. The experimental work was carried out using bubble column made of Perspex glass (5cm I.D, 120cm height). A liquid was at depth of 60cm. Different dosage of sawdust +bentonite at ratio 2:1 (0.5+ 0.25; 1+ 0.5 and 2+1) gm and alum at concentration (10,20and30mg/l) at different pH ( 4 and 7) were used to determine optimum dosages of coagulant. Jar test exper
... Show MoreThe research aims to study the corrosion of aluminum alloy(6061) in 0.6 mol. dm-3 NaCl solution in base medium was examined with out and with Gallic acid as environmentally – friendly corrosion inhibitor at temperature range (298-313)K. The inhibitive action of gallic acid on corrosion of aluminum alloy(6061) in KOH solution was examined through electrochemical polarization method using potentiostatic technique and surface analysis by optical microscopy, Polarization measurements indicate that the examined compound act as a mixed type inhibitor. Results appeared that the inhibition occurs through adsorption of the inhibitor molecules on the metal surface and it was obeyed
... Show MoreBackground: Acute myocardial infarction (AMI) is one of the most common diagnoses in hospitalized patients. Increased plasma hemostatic markers were noted in acute myocardial infarction, indicating that the blood coagulation system is highly activated in those patients. Aims of the study: To study the level of intrinsic coagulation factors including (FVIII:C, FIX:C ,FXI:C ,FXII:C ) in patients with acute myocardial infarction. Type of the study: Cross –sectional study. Methods: Thirty patients (their age range is 48-68 years) were included in this study (9 female, 21 male) who were just admitted to the coronary care unit in AL-Yarmouk Teaching Hospital and diagnosed as having acute myocardial infarction patients, blood samples were tak
... Show MoreEnvironmental pollution is regarded as a major problem, and traditional strategies such as chemical or physical remediation are not sufficient to overcome the problems of pollution. Petroleum-contaminated soil results in ecological problems, representing a danger to human health. Bioremediation has received remarkable attention, and it is a procedure that uses a biological agent to remove toxic waste from contaminated soil. This approach is easy to handle, inexpensive, and environmentally friendly; its results are highly satisfactory. Bioremediation is a biodegradation process in which the organic contaminants are completely mineralized to inorganic compounds, carbon dioxide, and water. This review discusses the bioremediation of petroleum-
... Show MoreThis study focused on treatment of real wastewater rejected from leather industry in Al-Nahrawan city in Iraq by Electrocoagulation (EC) process followed by Reverse Osmosis (RO) process. The successive treatment was applied due to high concentration of Cr3+ ions (about 1600 ppm) rejected in wastewater of this industry and for applying EC with moderate power consumption and better results of produced water. In Electrocoagulation process (EC), the effect of NaCl concentration (1.5, 3 g/l), current density (C.D.) (15-25 mA/cm2), electrolysis time (1-2 h), and distance between electrodes (E.D.) (1-2 cm) were examined in a batch cell by implementing Taguchi experimental design. According to the results obtained from multiple regression and signa
... Show MoreMicrobial fuel cell is a device that uses the microorganism metabolism for the production of electricity under specific operating conditions. Double chamber microbial fuel cell was tested for the use of two cheap electrode materials copper and aluminum for the production of electricity under different operating conditions. The investigated conditions were concentration of microorganism (yeast) (0.5- 2 g/l), solutions temperature (33-45 oC) and concentration of glucose as a substrate (1.5- 6 g/l). The results demonstrated that copper electrode exhibit good performance while the performance of aluminum is poor. The electricity is generated with and without the addition of substrate. Addition of glucose substrate
... Show MoreThis work presents a design for a pressure swing adsorption process (PSA) to separate oxygen from air with approximately 95% purity, suitable for different numbers of columns and arrangements. The product refill PSA process was found to perform 33% better (weight of zeolite required or productivity) than the pressure equalization process. The design is based on the adsorption equilibrium of a binary mixture of O2 and N2 for two of the most commonly used adsorbents, 5A & 13X, and extension from a single column approach. Zeolite 13X was found to perform 6% better than zeolite 5A. The most effective variables were determined to be the adsorption step time and the operational pressure. Increasing the adsorption step
... Show More