Preferred Language
Articles
/
ijcpe-360
Minimization of Toxic Ions in Waste Water Using Emulsion Liquid Membrane Technique
...Show More Authors

In the present study, the removal of zinc from synthetic waste water using emulsion liquid membrane extraction technique was investigated. Synthetic surfactant solution is used as the emulsifying agent. Diphenylthiocarbazon (ditizone) was used as the extracting agent dissolved in carbon tetrachloride as the organic solvent and sulfuric acid is used as the stripping agent. The parameters that influence the extraction percentage of Zn+2 were studied. These are the ratio of volume of organic solvent to volume of aqueous feed (0.5-4), ratio of volume of surfactant solution to volume of aqueous feed (0.2-1.6), pH of the aqueous feed solution (5-10), mixing intensity (100-1000) rpm, concentration of extracting agent (20-400) ppm, surfactant concentration (0.2-2) wt.%, contact time (3-30) min, and concentration of strip phase (0.25-2) M . It was found that 87.4% of Zn+2 can be removed from the aqueous feed solution at the optimum operating conditions. Further studies were carried out on extraction percentages of other toxic metal ions (As+3, Hg+2, Pb+2, Cd+2) by using the same optimum conditions which were obtained for zinc ions except for the pH of the feed solutions. The pH values for best extraction percentages of arsenic, lead, and cadmium were (1, 10, 10) respectively. Maximum extraction percentage of (98.5, 95.5 and 93.8) was obtained for arsenic, lead, and cadmium respectively, while mercury was completely removed from the aqueous feed solution within the acidic pH range.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Dec 31 2000
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Removal of Phenol from Water by Adsorption
...Show More Authors

View Publication Preview PDF
Publication Date
Thu Oct 01 2015
Journal Name
Journal Of Engineering
Quality Assurance for Iraqi Bottled Water Specifications
...Show More Authors

In this research the specifications of Iraqi drinking bottled water brands are investigated throughout the comparison between local brands, Saudi Arabia and the World Health Organization (WHO) for bottled water standard specifications. These specifications were also compared to that of Iraqi Tap Water standards. To reveal variations in the specifications for Iraqi bottled water,  and above mentioned standards some quality control tools are conducted for more than 33% of different bottled water brands (of different origins such as spring, purified,..etc) in Iraq by investigating the  selected quality parameters registered on their marketing labels. Results employing Minitab software (ver. 16) to generate X bar,

... Show More
View Publication Preview PDF
Publication Date
Wed Jul 01 2020
Journal Name
Iraqi Geological Journal
THE EFFECT OF SOME MATERIALS ON FUNNEL VISCOSITY READING IN WATER BASE MUD
...Show More Authors

View Publication
Crossref (2)
Crossref
Publication Date
Mon Nov 01 2021
Journal Name
Iop Conference Series: Earth And Environmental Science
A study of Irrigation Water Pollution By Some Heavy Metals in Baghdad Governorate
...Show More Authors
Abstract<p>A study of irrigation water was conducted Baghdad city to find out extent of its pollution by some heavy metals (Pb, Cd, Ni, Co, CU, Cr, Zn and Fe). Water samples were collected randomly from different sources (river, well and stream). Results showed that the concentration of studied heavy metals were as follows: Lead between 0.43-11.75 mg L<sup>-1</sup>, Cadmium between 0.01-0.95 mg L<sup>-1</sup>, Nickel between 0.008-0.46 mg L<sup>-1</sup>, Cobalt between Nil - 0.185 mg L<sup>-1</sup>, Copper is between 0.326 - 1.58 mg L<sup>-1</sup>, Chromium is between Nil-0.068 mg L<sup>-1</sup>, Zinc 0.398-1.182 mg L<sup>-1</sup>, as for Iro</p> ... Show More
View Publication
Scopus (3)
Crossref (1)
Scopus Crossref
Publication Date
Mon Oct 01 2018
Journal Name
Journal Of Global Pharma Technology
Assessment of heavy metals in some ground water wells at Baghdad City/Iraq
...Show More Authors

Occurrence the heavy metals in water is one of the most important concerns. may cause savior health problems. In this work we made an attempt to know the quantity of six heavy metals in groundwater in different locations of Baghdad city. Examinations were made on groundwater of the review region to assess the heavy metals. Groundwater samples were gathered and analyzed utilizing Atomic Absorption Spectrophotometer for their Manganese, Iron, Zinc, Cadmium, Copper and Lead content and their levels compared with World Health Organization (WHO) specified maximum contaminant level. In order to accomplish this, water samples were obtained from 10 randomly selected wells in the region, in February and August, 2016. The study showed that the ground

... Show More
Preview PDF
Scopus (5)
Scopus
Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
partial molal volume and viscosity study of vitamin B1 and B3 in water
...Show More Authors

the study covered theoretical concering parial molal volume the applicability of jones-dole equation

View Publication Preview PDF
Publication Date
Sun Jun 03 2018
Journal Name
Baghdad Science Journal
Spectrophotometric Determination of Sulphite in Various Water Samples Via Chromium-1,5-Diphenylcarbazide Complex
...Show More Authors

A simple and rapid spectrophotometric method for the determination of sulphite SO3-2 is described. The method is based on the rapid reduction of known amount of chromate CrO4-2 in the presence of sulphite in acidic medium of 2N H2SO4. The amount of excess of chromate was measured after it reactions with 1,5-diphenylcarbazide which finally gives a pink-violet, water soluble and stable complex, which exhibit a maximum absorption at 542 nm. Beer's law was obeyed in the concentration range from 0.004-6.0 µg of sulphite in a final volume of 25 ml with a molar absorbtivity of 4.64×104 l.mol-1.cm-1, Sandal's sensitivity index of 0.001724 ?g .cm-2 and relative standard deviation of ±0.55 - ±0.83 depending on the concentration level. The present

... Show More
View Publication Preview PDF
Scopus (5)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Fri May 18 2018
Journal Name
International Journal Of Simulation: Systems, Science &amp; Technology
A Review of Advances in Pressurizer Response Research for Pressurized Water Reactor Systems
...Show More Authors

View Publication
Crossref (1)
Crossref
Publication Date
Mon Dec 30 2013
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Corrosion Inhibition of Galvanic Couple Copper Alloy/Mild Steel in Cooling Water System
...Show More Authors

The driving idea for the present work was to combine the effect of polyvinyl alcohol (PVA) as corrosion inhibitor with the distance between the anodic and cathodic elements of the galvanic cell, beside their area ratio, in scope of synergistic suppression of galvanic corrosion on Cu/Fe model couple, using weight loss method. The performance affecting galvanic corrosion process has been tested for three major factors affect the process:
1. Four PVA inhibitor concentrations were selected to be (0, 1000, 4000 and 7000 ppm) in simulated cooling water.
2. Two cathode: anode area ratios as 1:1 and 2.4:1.
3. Two distances apart cathode – anode as 3 and 7 cm.
Maximum corrosion inhibition achieved was 86% which indicates that increa

... Show More
View Publication Preview PDF
Publication Date
Fri Mar 15 2019
Journal Name
Al-khwarizmi Engineering Journal
Theoretical Prediction of Optimum Chilled Water Distribution Configuration in Air Conditioning Terminal Unit
...Show More Authors

 The distribution of chilled water flow rate in terminal unit is a major factor used to evaluate the performance of central air conditioning unit. In this work, a theoretical chilled water distribution in the terminal units has been studied to predict the optimum heat performance of terminal unit. The central Air-conditioning unit model consists of cooling/ heating coil (three units), chilled water source (chiller), three-way and two-way valve with bypass, piping network, and pump. The term of optimization in terminal unit ingredient has two categories, the first is the uniform of the water flow rate representing in statically permanents standard deviation (minimum value) and the second category is the maximum heat transfer rate fro

... Show More
View Publication Preview PDF
Crossref