Simulation the Radiation Zone of Al-Mussaib Power Plant by Using Monte Carlo Method
...Show More Authors

The temperature distributions are to be evaluated for the furnace of Al-Mussaib power plant. Monte Carlo simulation procedure is used to evaluate the radiation heat transfer inside the furnace, where the radiative transfer is the most important process occurring there. Weighted sum of gray-gases model is used to evaluate the radiative properties of the non gray gas in the enclosure. The energy balance equations are applied for each gas, and surface zones, and by solving these equations, both the temperature, and the heat flux are found.

   Good degree of accuracy has been obtained, when comparing the results obtained by the simulation with the data of the designing company, and the data obtained by the zonal method. In the above work, a code of Monte Carlo method is built, and used to overcome the mathematical analysis.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Oct 01 2015
Journal Name
Journal Of Engineering
Numerical Simulation of Natural Convection Heat Transfer from Interrupted Rectangular Fins
...Show More Authors

      Numerical simulations have been investigated to study the external free convective heat transfer from a vertically rectangular interrupted fin arrays. The continuity, Naver-Stockes and energy equations have been solved for steady-state, incompressible, two dimensional, laminar with Boussiuesq approximation by Fluent 15 software. The performance of interrupted fins was evaluated to gain the optimum ratio of interrupted length to fin length (

View Publication Preview PDF
Publication Date
Sun Jun 01 2014
Journal Name
Journal Of Water Resource And Hydraulic Engineering (jwrhe)
Large Scale Field Physical Model Simulation of Roseires Dam-Break, Sudan
...Show More Authors

Physically based modeling approach has been widely developed in recent years for the simulation of dam failure process due to the lack of field data. This paper provides and describes a physically-based model depending on dimensional analysis and hydraulic simulation methods for estimating the maximum water level and the wave propagation time from breaching of field test dams. The field physical model has been constructed in Dabbah city to represent the collapse of the Roseires dam in Sudan. Five cases of a dam failure were studied to simulate water flood conditions by changing initial water height in the reservoir (0.8, 1.0, 1.2, 1.4 and 1.5 m respectively).The physical model working under five cases, case 5 had the greatest influence of t

... Show More
Publication Date
Tue Mar 01 2016
Journal Name
Journal Of Engineering
Design and Simulation of Sliding Mode Fuzzy Controller for Nonlinear System
...Show More Authors

Sliding Mode Controller (SMC) is a simple method and powerful technique to design a robust controller for nonlinear systems. It is an effective tool with acceptable performance. The major drawback is a classical Sliding Mode controller suffers from the chattering phenomenon which causes undesirable zigzag motion along the sliding surface. To overcome the snag of this classical approach, many methods were proposed and implemented. In this work, a Fuzzy controller was added to classical Sliding Mode controller in order to reduce the impact chattering problem. The new structure is called Sliding Mode Fuzzy controller (SMFC) which will also improve the properties and performance of the classical Sliding Mode control

... Show More
View Publication Preview PDF
Publication Date
Sat Dec 17 2022
Journal Name
Journal Of Al-ma'moon College
Simulation and Implementation of SNR Measurement processor for Adaptive Communication Systems
...Show More Authors

Preview PDF
Publication Date
Tue Dec 26 2017
Journal Name
Al-khwarizmi Engineering Journal
Simulation Recording of an ECG, PCG, and PPG for Feature Extractions
...Show More Authors

Recently, the development of the field of biomedical engineering has led to a renewed interest in detection of several events. In this paper a new approach used to detect specific parameter and relations between three biomedical signals that used in clinical diagnosis. These include the phonocardiography (PCG), electrocardiography (ECG) and photoplethysmography (PPG) or sometimes it called the carotid pulse related to the position of electrode.

Comparisons between three cases (two normal cases and one abnormal case) are used to indicate the delay that may occurred due to the deficiency of the cardiac muscle or valve in an abnormal case.

The results shown that S1 and S2, first and second sound of the

... Show More
View Publication Preview PDF
Publication Date
Fri Jul 21 2023
Journal Name
Journal Of Engineering
Simulation of Heat Storage and Heat Regeneration in Phase Change Material
...Show More Authors

The present study explores numerically the energy storage and energy regeneration during Melting and Solidification processes in Phase Change Materials (PCM) used in Latent Heat Thermal Energy Storage (LHTES) systems. Transient two-dimensional (2-D) conduction heat transfer equations with phase change have been solved utilizing the Explicit Finite Difference Method (FDM) and Grid Generation technique. A Fortran computer program was built to solve the problem. The study included four different Paraffin's. The effects of container geometrical shape, which included cylindrical and square sections of the same volume and heat transfer area, the container volume or mass of PCM, variation of mass flow rate of heat transfer fluid (HTF), and temp

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Sun Nov 01 2015
Journal Name
Journal Of Engineering
Numerical Simulation of Flow in Rectangular Duct with Different Obstruction Heights
...Show More Authors

       In this study, a simulation model inside a channel of rectangular section with high of (0.16 m) containing two rectangular obstruction plates were aligned variable heights normal to the direction of flow, use six model of the obstructions height of (0.059, 0.066, 0.073, 0.08 and 0.087 m) were compared with the flow behavior of the same duct without obstructions. To predict the velocity profile, pressure distribution, pressure coefficient and turbulence kinetic energy flow of air, the differential equations which describe the flow were approximated by the finite volumes method for two dimensional, by using commercial software package (FLUENT) with standard of k-ε model two dimensions turbulence flow.

... Show More
View Publication Preview PDF
Publication Date
Sun Aug 01 2021
Journal Name
International Journal Of Electrical And Computer Engineering (ijece)
Simulation based comparison of routing protocols in wireless multihop adhoc networks
...Show More Authors

Routing protocols are responsible for providing reliable communication between the source and destination nodes. The performance of these protocols in the ad hoc network family is influenced by several factors such as mobility model, traffic load, transmission range, and the number of mobile nodes which represents a great issue. Several simulation studies have explored routing protocol with performance parameters, but few relate to various protocols concerning routing and Quality of Service (QoS) metrics. This paper presents a simulation-based comparison of proactive, reactive, and multipath routing protocols in mobile ad hoc networks (MANETs). Specifically, the performance of AODV, DSDV, and AOMDV protocols are evaluated and analyz

... Show More
View Publication
Crossref (12)
Crossref
Publication Date
Fri Jun 20 2025
Journal Name
Journal Of Kufa For Chemical Sciences
Biosynthesis of Zirconium Oxide Nanoparticles from Different Plant Extracts: A Review
...Show More Authors

View Publication
Publication Date
Tue Jan 08 2019
Journal Name
Iraqi Journal Of Physics
Simulation and experimental study of Pin-Plate DC discharge plasma technique
...Show More Authors

The present work intends to study of dc glow discharge were generated between pin (cathode) and a plate (anode) in Ar gas is performed using COMSOL were used to study electric field distribution along the axis of the discharge and also the distribution of electron density and electron temperature at constant pressure (P=.0.0mbar) and inter electrode distance (d=4 cm) at different applied voltage for both pin cathode system and plate anode and comparison with experimental results.

View Publication Preview PDF
Crossref (1)
Crossref