An experimental and numerical study was carried out to investigate the heat transfer by natural convection in a three dimensional annulus enclosure filled with porous media (silica sand) between two inclined concentric cylinders with (and without) annular fins attached to the inner cylinder under steady state condition. The experiments were carried out for a range of modified Rayleigh number (0.2 ≤Ra*≤ 11) and extended to Ra*=500 for numerical study and for annulus inclination angle of (δ = 0˚, 30˚, 60˚ and 90˚). The numerical study was to give the governing equation under assumptions that used Darcy law and Boussinesq’s approximation and then it was solved numerically using finite difference approximation. It was found that the average Nusselt number depends on (Ra*, Hf, δ and Rr ). The results showed that the increasing of the fin length increases the heat transfer rate for any fin pitch unless the area of the inner cylinder exceeds that of the outer one; then the heat will be stored in the porous media. A comparison was made between the results of the present work and those of other researches for the case without fins and excellent agreement was obtained.
A vector in a separable infinite dimensional Hilbert space is called disk-cyclic for bounded operator if the orbit α : 0, α∈;|∝| 1is dense in. The useful tool used to discover codisk-cyclic operation is called the disk-cyclic Criterion. In this paper we will show that some equivalent conditions of the
Psi prepared by Electrochemical etching technique at invariable etching current density of 10 mA/cm2 and at different times (7 and 17) min. The porous Si structure was studied using XRD, (FE-SEM) and EDS. The process of sensing NH3 gas is carried out at different operating temperatures (R.t,80,130 and 200)°C and the gas concentration is constant. It is measured by changing the resistance of the sensor as a function of exposure time to the gas. The result showed the XRD patterns of the PS at (7 and 17) min etching time. the peak samples at (111) around 2θ = 28.5°. It is observed that the peak intensity declines with rising the etching time,
The influence of adding metal foam fins on the heat transfer characteristics of an air to water double pipe heat exchanger is numerically investigated. The hot fluid is water which flows in the inner cylinder whereas the cold fluid is air which circulates in the annular gap in parallel flow with water. Ten fins of metal foam (Porosity = 0.93), are added in the gap between the two cylinder, and distributed periodically with the axial distance. Finite volume method is used to solve the governing equations in porous and non-porous regions. The numerical investigations cover three values for Reynolds number (1000 ,1500, 2000), and Darcy number (1 x10-1, 1 x10-2, 1x10-3). The comparison betwee
... Show MoreThis work evaluates the influence of combining twisted fins in a triple-tube heat exchanger utilised for latent heat thermal energy storage (LHTES) in three-dimensional numerical simulation and comparing the outcome with the cases of the straight fins and no fins. The phase change material (PCM) is in the annulus between the inner and the outer tube, these tubes include a cold fluid that flows in the counter current path, to solidify the PCM and release the heat storage energy. The performance of the unit was assessed based on the liquid fraction and temperature profiles as well as solidification and the energy storage rate. This study aims to find suitable and efficient fins number and the optimum values of the Re and the inlet tem