In all process industries, the process variables like flow, pressure, level, concentration
and temperature are the main parameters that need to be controlled in both set point
and load changes.
A control system of propylene glycol production in a non isothermal (CSTR) was
developed in this work where the dynamic and control system based on basic mass
and energy balance were carried out.
Inlet concentration and temperature are the two disturbances, while the inlet
volumetric flow rate and the coolant temperature are the two manipulations. The
objective is to maintain constant temperature and concentration within the CSTR.
A dynamic model for non isothermal CSTR is described by a first order plus dead
time (FOPDT).
The conventional PI and PID control were studied and the tuning of control
parameters was found by Ziegler-Nichols reaction curve tuning method to find the
best values of proportional gain (Kc), integral time ( I) and derivative time ( D).
The conventional controller tuning is compared with IMC techniques in this work and
it was found that the Ziegler –Nichols controller provides the best control for the
disturbance and the worst for the set-point change, while the IMC controller results
show satisfactory set-point responses but sluggish disturbance responses because the
approximate FOPTD model has relatively small time delay.
Feedforward and feedforward combined with feedback control systems were used as
another strategy to compare with above strategies. Feedforward control provides a
better response to disturbance rejection than feedback control with a steady state
deviation (offset). Thus, a combined feedforward-feedback control system is preferred
in practice where feedforward control is used to reduce the effects of measurable
disturbances, while feedback trim compensates for inaccuracies in the process model,
measurement error, and unmeasured disturbances. Also the deviation (offset) in
feedforward control was eliminated.
CNC machines are widely used in production fields since they produce similar parts in a minimum time, at higher speed and with possibly minimum error. A control system is designed, implemented and tested to control the operation of a laboratory CNC milling machine having three axes that are moved by using a stepper motor attached to each axis. The control system includes two parts, hardware part and software part, the hardware part used a PC (works as controller) connected to the CNC machine through its parallel port by using designed interface circuit. The software part includes the algorithms needed to control the CNC. The sample needs to be machined is drawn by using one of the drawing software like AUTOCAD or 3D MAX and is saved in a we
... Show MoreThe objective of this research paper is two-fold. The first is a precise reading of the theoretical underpinnings of each of the strategic approaches: "Market approach" for (M. Porter), and the alternative resource-based approach (R B V), advocates for the idea that the two approaches are complementary. Secondly, we will discuss the possibility of combining the two competitive strategies: cost leadership and differentiation. Finally, we propose a consensual approach that we call "dual domination".
This paper studies a novel technique based on the use of two effective methods like modified Laplace- variational method (MLVIM) and a new Variational method (MVIM)to solve PDEs with variable coefficients. The current modification for the (MLVIM) is based on coupling of the Variational method (VIM) and Laplace- method (LT). In our proposal there is no need to calculate Lagrange multiplier. We applied Laplace method to the problem .Furthermore, the nonlinear terms for this problem is solved using homotopy method (HPM). Some examples are taken to compare results between two methods and to verify the reliability of our present methods.
Background: The prevalence of obesity is continuously rising world-wide. Obesity is an important risk factor of cardiovascular disease (CVD), metabolic syndrome (MS), and type 2 diabetes (T2D).
Objective: To estimate the frequency of MS in obese versus non-obese subjects in Basrah, Iraq .
Methods: This is a prospective clinical study performed in Al-Sadr Teaching Hospital, Basrah, and included 86 obese subjects (with a BMI ≥ 30), 39 males and 47 females, and 132 non-obese subjects ( with a BMI < 30 ), 60 males and 73 females as a control group. Measurement of height, weight, waist circumference (WC), blood pressure ( BP ), fasting blood glucose ( FBG ), total cholesterol (TC), triglycerides (TG ) and high density lipoprotein-
In this work, the effect of aluminum (Al) dust particles on the DC discharge plasma properties in argon was investigated. A magnetron is placed behind the cathode at different pressures and with varying amounts of Al. The plasma temperature (Te) and density (ne) were calculated using the Boltzmann equation and Stark broadening phenomena, which are considered the most important plasma variables through which the other plasma parameters were calculated. The measurements showed that the emission intensity decreases with increasing pressure from 0.06 to 0.4 Torr, and it slightly decreases with the addition of the NPs. The calculations showed that the ne increased and Te decreased with pressure. Both Te and ne were reduced by increasing
... Show MoreThis study was design to investigate the dimensional stability of heat-activated acrylic resin with different methods of flask cooling (15 minutes rapid cooling, one hour bench cooling, four hours delayed deflasking, and 24 hours delayed deflasking) at different time intervals (immediately, two days, seven days, 30 days) after deflasking. Heat-activated acrylic resin was used to prepare acrylic samples. Then, measurement of the distances where achieved between the centers of selected marks in the acrylic samples. They were measured at different time intervals for different methods of flask cooling. The results showed that the group samples of the four hours and 24 hours of delayed deflasking was insignificantly different from the control an
... Show More