Preferred Language
Articles
/
ijcpe-328
Extraction of Pelletierine from Punica granatum L.by Liquid Membrane Technique and Modelling
...Show More Authors

This work was conducted to study the extraction of pelletierine sulphate from Punica granatum L. roots by liquid membrane techniques. Pelletierine sulphate is used widely in medicine. The general behavior of extraction process indicates that pelletierine conversion increased with increasing the number of stages and the discs rotation speed but high rotation speed was not favored because of the increased risk of droplet formation during the operation. The pH of feed and acceptor solution was also important. The results exhibit that the highest pelletierine conversion was obtained when using two stages, (10 rpm) discs speed of stainless steel discs, (pH=9.5) of feed solution and (pH=2) of acceptor solution in n-decane. Assuming the existence of two thin reaction layers in the feed and stripping solutions, mathematical model was developed to describe the pelletierine transport. On the basic of the experimental data obtained under various conditions and the model proposed, it was found that the solute transfer into the liquid membrane is mainly diffusion-controlled.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Feb 01 2023
Journal Name
Baghdad Science Journal
Breast Cancer MRI Classification Based on Fractional Entropy Image Enhancement and Deep Feature Extraction
...Show More Authors

Disease diagnosis with computer-aided methods has been extensively studied and applied in diagnosing and monitoring of several chronic diseases. Early detection and risk assessment of breast diseases based on clinical data is helpful for doctors to make early diagnosis and monitor the disease progression. The purpose of this study is to exploit the Convolutional Neural Network (CNN) in discriminating breast MRI scans into pathological and healthy. In this study, a fully automated and efficient deep features extraction algorithm that exploits the spatial information obtained from both T2W-TSE and STIR MRI sequences to discriminate between pathological and healthy breast MRI scans. The breast MRI scans are preprocessed prior to the feature

... Show More
View Publication Preview PDF
Scopus (33)
Crossref (11)
Scopus Clarivate Crossref
Publication Date
Sun May 01 2016
Journal Name
Journal Of Engineering
Prediction of Ryznar Index for the treated water from WTPs on Al-Karakh side of Baghdad City using Artificial Neural Network (ANN) technique
...Show More Authors

In this research an Artificial Neural Network (ANN) technique was applied for the prediction of Ryznar Index (RI) of the flowing water from WTPs in Al-Karakh side (left side) in Baghdad city for year 2013. Three models (ANN1, ANN2 and ANN3) have been developed and tested using data from Baghdad Mayoralty (Amanat Baghdad) including drinking water quality for the period 2004 to 2013. The results indicate that it is quite possible to use an artificial neural networks in predicting the stability index (RI) with a good degree of accuracy. Where ANN 2 model could be used to predict RI for the effluents from Al-Karakh, Al-Qadisiya and Al-Karama WTPs as the highest correlation coefficient were obtained 92.4, 82.9 and 79.1% respectively. For

... Show More
Publication Date
Sun Mar 13 2011
Journal Name
Baghdad Science Journal
Evaluation the efficiency of different techniques for extraction and purification of Tomato yellow leaf curl virus (TYLCV)
...Show More Authors

This study was conducted to evaluate the efficacy of different techniques for extraction and purification of Tomato yellow leaf curl virus (TYLCV). An isolate of the virus free of possible contamination with other viruses infecting the same host and transmitted by the same vector Bemisia tabaci Genn. was obtained. This was realized by indicator plants and incubation period in the vector. Results obtained revealed that the virus infect Nicotiana glutinosa without visible symptoms, while Nicotiana tabaccum var. White Burley was not susceptible to the virus. The incubation period of the virus in the vector was found to be 21 hrs. These results indicate that the virus is TYLCV. Results showed that Butanol was more effective in clarification the

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Mon Nov 15 2021
Journal Name
Aip Conference Proceedings
Oil skimming followed by coagulation/flocculation processes for oilfield produced water treatment and zero liquid discharge system application
...Show More Authors

The study focused on the treatment of real oilfield produced water from the East Baghdad field affiliated to the Midland Oil Company (Iraq) using an oil skimming process followed by a coagulation/flocculation process for zero liquid discharge system applications. Belt type oil skimmer was utilized for evaluating the process efficiency with various operating conditions such as temperature (17-40 °C) and time (0.5-2.5 hr.). Polyaluminum chloride (PAC) coagulant and polyacrylamide (PAM) flocculant was used to investigate the performance of the coagulation/flocculation process with PAC dosage (5-90 ppm) and pH (5-10) as operating conditions. In the skimming process, the oil content, COD, turbidity, and TSS decreased with an increase in tempera

... Show More
View Publication
Publication Date
Mon Jun 08 2020
Journal Name
Research Journal Of Chemistry And Environment
High Performance Liquid Chromatographic and Areaunder Curve spectrophotometric Methods forEstimation of Cefixime in Pure and MarketedFormulation: A Comparative Study
...Show More Authors

Cefixime is an antibiotic useful for treating a variety ofmicroorganism infections. In the present work, tworapid, specific, inexpensive and nontoxic methods wereproposed for cefixime determination. Area under curvespectrophotometric and HPLC methods were depictedfor the micro quantification of Cefixime in highly pureand local market formulation. The area under curve(first technique) used in calculation of the cefiximepeak using a UV-visible spectrophotometer.The HPLC (2nd technique) was depended on thepurification of Cefixime by a C18 separating column250mm (length of column) × 4.6 mm (diameter)andusing methanol 50% (organic modifier) and deionizedwater 50% as a mobile phase. The isocratic flow withrate of 1 mL/min was applied, the temper

... Show More
Publication Date
Mon Jan 01 2018
Journal Name
World Journal Of Dentistry
Factors affecting the Duration of Surgical Extraction of Impacted Mandibular Third Molars
...Show More Authors

Aim The aim of this study is to evaluate the effect of demographic, clinical, and radiographic factors on the duration of surgical extraction of impacted lower third molars. Materials and methods This retrospective study included patients who underwent surgical removal of impacted lower third molars, and the investigated factors were demographic data including age and gender, radiographic data including the impacted tooth angulation and depth of impaction and ramus relation, and clinical data including the state of eruption of the impacted teeth. These factors were evaluated for association with the duration of surgery. Descriptive statistical analysis included percentages and mean ± standard deviation (SD). Student's t-test was used to co

... Show More
View Publication
Scopus (5)
Crossref (4)
Scopus Crossref
Publication Date
Sat Sep 01 2018
Journal Name
Journal Of Global Pharma Technology
Synthesis ,Characterization and Study of Liquid Crystalline Behavior of New Compounds Containing thiazolidin-4-one,1,2,3-triazole and benzimidazol Rings
...Show More Authors

All new compounds synthesized by many reactions starting from a product the compounds [I]a,b from reaction of 3-phenylenediamine or 4-phenylenediamine with chloroacetyl chloride, then the compounds [I]a,b reacted with potassium thiocyanate to yield compounds [II]a,b. While the compounds[III]a,b yield from reacted the compounds [I]a,b with sodium azide then the compounds [III]a,b reacted 1,3-dipolar cycloaddition reaction with acrylic acid to give compounds [IV]a,b and the later compounds reacted with phenylene diamine to product benzimidazole compounds [V]a,b . In addition to synthesized acid chloride compounds [VI]a,b by reacted the compounds [IV]a,b with thionyl chloride .Finally reacted the compounds [VI]a,b with different aromatic amine

... Show More
Publication Date
Wed Jan 01 2020
Journal Name
Fme Transactions
Development of automated liquid filling system based on the interactive design approach
...Show More Authors

The automatic liquid filling system is used in different applications such as production of detergents, liquid soaps, fruit juices, milk products, bottled water, etc. The automatic bottle filling system is highly expensive. Where, the common filling systems required to complex changes in hardware and software in order to modify volume of liquid. There are many important variables in the filling process such as volume of liquid, the filling time, etc. This paper presents a new approach to develop an automatic liquid filling system. The new proposed system consists of a conveyor subsystem, filling stations, and camera to detect the level of the liquid at any instant during the filling process. The camera can detect accurately the leve

... Show More
View Publication
Scopus (20)
Crossref (17)
Scopus Clarivate Crossref
Publication Date
Sat Jun 01 2019
Journal Name
Telematics And Informatics
Corrigendum to “Modelling the utilization of cloud health information systems in the Iraqi public healthcare sector” [Telematics and Informatics, 36 (2019) 132–146]
...Show More Authors

View Publication
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Sun Sep 01 2013
Journal Name
Baghdad Science Journal
High performance liquid chromatographic method for the determination of guaifenesin in pharmaceutical syrups and in environmental samples
...Show More Authors

A simple, precise, rapid, and accurate reversed – phase high performance liquid chromatographic method has been developed for the determination of guaifenesin in pure from pharmaceutical formulations.andindustrial effluent. Chromatography was carried out on supelco L7 reversed- phase column (25cm × 4.6mm), 5 microns, using a mixture of methanol –acetonitrile-water: (80: 10 :10 v/v/v) as a mobile phase at a flow rate of 1.0 ml.min-1. Detection was performed at 254nm at ambient temperature. The retention time for guaifenesin was found 2.4 minutes. The calibration curve was linear (r= 0.9998) over a concentration range from 0.08 to 0.8mg/ml. Limit of detection (LOD) and limit of quantification ( LOQ) were found 6µg/ml and 18µg/ml res

... Show More
View Publication Preview PDF