Preferred Language
Articles
/
ijcpe-320
Mass Transfer Enhancement Using Extensions as Turbulence Promoters
...Show More Authors

Mass transfer was studied using a rotating cylinder electrode with different lengths of legs acting as turbulence promoters. Two types of rotating cylinder ,made of brass, were examined : an enhanced cylinder one, with four rectangular extensions 10 mm long, 10 mm wide, and 1mm thick, and an enhanced cylinder two with four longitudes 30 mm long,10 mm wide, and 1mm thick. The best performance was obtained for enhanced cylinder two at low rotation speeds while enhanced cylinder one was realized at high rotation speeds. The mass transfer enhancement as compared with a normal rotating cylinder electrode, devoid of promoters, is 53% or 58% higher. The enhancement percentage decreased as rotation speeds increased further, since, seemingly, full turbulence has been reached practically by means of rotation and turbulence promoters.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Jan 01 2019
Journal Name
Energy Procedia
Threshold Current Density of Al0.1Ga0.9N/GaN Triple Quantum Well Laser
...Show More Authors

Semiconductor laser is used in processing many issues related to the scientific, military, medical, industrial and agricultural fields due to its unique properties such as coherence and high strength where GaN-based components are the most efficient in this field. Current technological developments mention to the strong connection of GaN with sustainable electronic and optoelectronic devices which have high-efficiency. The threshold current density of Al0.1Ga0.9N/GaN triple quantum well laser structure was investigated to determine best values of the parameters affecting the threshold current density that are well width, average thickness of active region, cavity length, reflectivity of cavity mirrors and optical confinement factor. The opt

... Show More
View Publication
Scopus (6)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Sun Dec 04 2011
Journal Name
Baghdad Science Journal
Some Non-destructive Testing for Al metal in 0.1N of NaCl and NaOH
...Show More Authors

In this work the corrosion behavior of Al metal was studied by using non- destructive testing (NDT), which is a noninvasive technique for determining the integrity of a material. The ultrasonic waves was used to measure the corrosion which occur by two corrosive medium (0.1N sodium chloride and 0.1N sodium hydroxide) and study the corrosion by weight-loss method and electrochemical method in addition to performance the microscopic inspection for the samples before and after the immersion in the corrosive medium. Corrosion parameters were interpreted in these media which involve corrosion potential (Ecorr) and corrosion current density (icorr). The results indicate that both

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Apr 29 2018
Journal Name
Iraqi Journal Of Science
Signal Processing Techniques for Diagnosis Rotor Faults in Small Wind Turbine Motor
...Show More Authors

The core objective of this paper was to diagnosis and detect the expected rotor faults in small wind turbine SWT utilize signal processing technique. This aim was achieved by acquired and analyzed the current signal of SWT motor and employed the motor current signature analysis MCSA to detect the sudden changes can have occurred during SWT operation. LabVIEW program as a virtual instrument and (NI USB 6259) DAQ were take advantage of current measurement and data processing.

View Publication Preview PDF
Publication Date
Wed Aug 01 2007
Journal Name
Al-nahrain Journal For Engineering Sciences
Monitoring and Control on Impressed Current Cathodic Protection for Oil Pipelines
...Show More Authors

This research is devoted to design and implement a Supervisory Control and Data Acquisition system (SCADA) for monitoring and controlling the corrosion of a carbon steel pipe buried in soil. A smart technique equipped with a microcontroller, a collection of sensors and a communication system was applied to monitor and control the operation of an ICCP process for a carbon steel pipe. The integration of the built hardware, LabVIEW graphical programming and PC interface produces an effective SCADA system for two types of control namely: a Proportional Integral Derivative (PID) that supports a closed loop, and a traditional open loop control. Through this work, under environmental temperature of 30°C, an evaluation and comparison were done for

... Show More
View Publication Preview PDF
Publication Date
Thu Dec 01 2011
Journal Name
Journal Of Engineering
THEORETICAL AND EXPERIMENTAL STUDY ON THERMAL PERFORMANCE OF CLOSED WET COOLING TOWER
...Show More Authors

Thermal performance of closed wet cooling tower has been investigated experimentally and theoretically
in this work. The theoretical model based on heat and mass transfer equations and heat and mass transfer balance equations which are established for steady state case. A new small indirect cooling tower was used for conducting experiments. The cooling capacity of cooling tower is 1 kW for an inlet water temperature of 38oC, a water mass velocity 2.3 kg/m2.s and an air wet bulb temperature of 26oC. This study investigates the relationship between saturation efficiency, cooling capacity and coefficient of performance of closed wet cooling tower versus different operating parameters such wet-bulb temperature, variable air-spray water fl

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Dec 30 2023
Journal Name
Iraqi Journal Of Science
Effect of Voltage on Gas Sensor Performance of Anodization Synthesized TiO2 Nanotubes Arrays
...Show More Authors

     Serious gases have been highly related to being prejudiced against human life within the environment. The evolution of a trustworthy gas sensor with an elevated response is of major importance for detecting various hazardous gases. Titanium dioxide (TiO2) nanotubes (TNTs) are favorable candidates with considerable potential and stellar performance in gas sensor applications. In this work, we have studied the effect of voltage on preparing TiO2 nanotubular arrays via the anodization technique for gas sensor applications. A simple electrochemical anodization approach was used to synthesize titanium dioxide nanotubes. Diverse techniques of characterization were used to evaluate TNTs. The results gained from fi

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Fri Dec 01 2023
Journal Name
Iraqi Journal Of Physics
Gas Sensor for Hazardous Nitrogen Dioxide Based on TiO2 Nanotube Synthesis via Electrochemical Method
...Show More Authors

Because of the quick growth of electrical instruments used in noxious gas detection, the importance of gas sensors has increased. X-ray diffraction (XRD) can be used to examine the crystal phase structure of sensing materials, which affects the properties of gas sensing. This contributes to the study of the effect of electrochemical synthesis of titanium dioxide (TiO2) materials with various crystal phase shapes, such as rutile TiO2 (R-TiO2NTs) and anatase TiO2 (A-TiO2NTs). In this work, we have studied the effect of voltage on preparing TiO2 nanotube arrays via the anodization technique for gas sensor applications. The results acquired from XRD, energy dispersion spectro

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Dec 06 2015
Journal Name
Baghdad Science Journal
The Effect of The Electrochemical Deposition Potential Variation on The Coating of Hydroxyatite on Commertialy pure Titanium (CpTi) and Ti-6Al-4V Alloy
...Show More Authors

In this research we investigated the corrosion behavior of the commertialy pure titanium and Ti-6Al-4V alloy that coated with hydroxyapatite by electrochemical deposition with applied voltage (6,9,12) Volt from aqueous solution containing Ca(NO3)2.H2O =7.0 gm/l , (NH4)2HPO4 =3.5 gm/l , Na(NO3)2 = 8.5 gm/l in order to improve the bonding strength of hydroxyapetite and medical metals and alloys and increasing the biocompatibility. The coating layer morphology was investigated by XRD, Optical microscope , and SEM tests, the corrosio tests was made by use senthesys simulated body fluid (SBF) , and we found that the propreate voltage for coatint on Ti was 9 Volt and for Ti-6Al-4Vwas12Volt.

View Publication Preview PDF
Crossref
Publication Date
Wed Nov 01 2023
Journal Name
Ecological Engineering & Environmental Technology
Synthesis of Mn-Co-Ni Composite Electrode by Anodic and Cathodic Electrodeposition for Indirect Electro-oxidation of Phenol – Optimization of the Removal by Response Surface Methodology
...Show More Authors

In the present work, Response Surface Methodology (RSM) was utilized to optimize process variables and find the best circumstances for indirect electrochemical oxidation of mimicked wastewater to remove phenol contaminants using prepared ternary composite electrode. The electrodeposition process is used for the synthesis of a ternary composite electrode of Mn, Co, and Ni oxides. The selected concentrations of metal salts of these elements were 0.05, 0.1, and 1.5 M, with constant molar ratio, current density, and electrolysis time of 1:1:1, 25 mA/cm2, and 2 h. Interestedly, the gathered Mn-Co-Ni oxides were deposited at both the anode and cathode. X-ray diffraction (XRD) and scanning electron microscopy (SEM) facilitated the qualitative char

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (2)
Scopus Crossref
Publication Date
Mon Jun 03 2019
Journal Name
Al-kindy College Medical Journal
A Case Report -Bilateral Giant Achilles Tendon Xanthomas Resection with a Tendon transverse Technique
...Show More Authors

Background : Xanthomatosis is a disease in which large tendon tumors can occur, especially in the Achilles tendon. This disease is a rare interesting orthopaedic condition. Case Report:A case of a twenty eight year old girl patient with giant bilateral Achilles tendon xanthomas in which both tumors were resected. There was no ulceration on the both sides. The patient was treated by total resection of the lesion and reconstruction using tendon transfer of the Peroneus brevis and Flexor hallusis longus. Postoperative treatment consisted of six weeks lower leg cast immobilization followed by partial weight bearing. After 4 months the patient was able to walk pain free without any difficulties. It has been suggested that total resection with au

... Show More
View Publication Preview PDF