Iraq has a huge network of pipelines, transport crude oil and final hydrocarbon products as well as portable water. These networks are exposed to extensive damage due to the underground corrosion processes unless suitable protection techniques are used. In this paper we collect the information of cathodic protection for pipeline in practical fields (Oil Group in Al Doura), to obtain data base to understand and optimize the design which is made by simulation for the environmental factors and cathodic protection variables also soil resistivity using wenner four terminal methods for survey sites; and soil pH investigations were recorded for these selected fields were within 7-8, and recording the anodes voltage and its related currents for the protection of underground pipelines.
Modeling enables the designer to build cathodic protection for buried structure and predicting the places of anodes sites and its operating voltages and currents under various operational conditions, and comparing it with those in practices. In this work we compared between the field and simulation results which include, anode numbers, rectifier voltage, rectifier current and anode resistance. The most economical design for the first pipeline was at station no. 2 which need 2.5 A for protection of the pipeline for that specific length and for second pipeline station no. 4 which need 12 A for protection of the pipeline for that specific length.
Investigation of the adsorption of acid fuchsin dye (AFD) on Zeolite 5A is carried out using batch scale experiments according to statistical design. Adsorption isotherms, kinetics and thermodynamics were demonstrated. Results showed that the maximum removal efficiency was using zeolite at a temperature of 93.68751 mg/g. Experimental data was found to fit the Langmuir isotherm and pseudo second order kinetics with maximum removal of about 95%. Thermodynamic analysis showed an endothermic adsorption. Optimization was made for the most affecting operating variables and a model equation for the predicted efficiency was suggested.
The study aimed to reveal the obstacles of administrative creativity among the leaders of secondary schools (the curriculum system) in the northern border region, which relate to the obstacles (organizational, motivational, and psychological). In addition, to identify the most important statistical differences between the responses of the members of the study sample, which attribute to the variables (educational qualification, year’s Administrative expertise). To achieve the goal of the study, the researcher used the descriptive analytical approach, and to verify the validity of the tool, it has presented to several referees and faculty members in the educational field. The validity of the internal consistency was also calculated for t
... Show MoreIn this paper deals with the effect laser irradiation on the optical properties of cobalt oxide (CoO2) thin films and that was prepared using semi computerized spray pyrolysis technique. The films deposited on glass substrate using such as an ideal value concentration of (0.02)M with a total volume of 100 ml. With substrate temperature was (350 C), spray rate (15 ml/min).The XRD diffraction given polycrystalline nature with Crystal system trigonal (hexagonal axes). The obtained films were irradiated by continuous green laser (532.8 nm) with power 140 mW for different time periods is 10 min,20min and 30min. The result was that the optical properties of cobalt oxide thin films affe
The primary goal of in-situ load testing is to evaluate the safety and performance of a structural system under particular loading conditions. Advancements in building techniques, analytical tools, and monitoring instruments are prompting the evaluation of the appropriate loading value, loading process, and examination criteria. The procedure for testing reinforced concrete (RC) structures on-site, as outlined in the ACI Building Code, involves conducting a 24-h load test and applying specific evaluation criteria. This article detailed a retrofitting project for an RC slab-beams system by utilizing carbon fiber-reinforced polymer (CFRP) sheets to strengthen the structure following a fire incident. The RC structure showed indicators of deter
... Show MoreRepresent a topic occupational safety and health management is one of the priorities of the loading organization in the business environment ,and one of the requirement for the success and its impact on the productivity of workers and their performance in an appropriate working environment .The international responses to the problems that accompany the technological and industrial development of the business environment are the issuance of ISO 45001:2018 aimed at providing an appropriate framework for controlling risks , reducing injuries and work accidents and improving work performance ,after realizing the environmental relationship between safe and sound work with competition .The search’s issue is represented with the exist
... Show MoreThe current research aims to study the extent to which the Independent High Electoral Commission applies to information security risk management by the international standard (ISO / IEC27005) in terms of policies, administrative and technical procedures, and techniques used in managing information security risks, based on the opinions of experts in the sector who occupy positions (General Manager The directorate, department heads and their agents, project managers, heads of divisions, and those authorized to access systems and software). The importance of the research comes by giving a clear picture of the field of information security risk management in the organization in question because of its significant role in identifying risks and s
... Show MoreA twisted-fin array as an innovative structure for intensifying the charging response of a phase-change material (PCM) within a shell-and-tube storage system is introduced in this work. A three-dimensional model describing the thermal management with charging phase change process in PCM was developed and numerically analyzed by the enthalpy-porosity method using commercial CFD software. Efficacy of the proposed structure of fins for performing better heat communication between the active heating surface and the adjacent layers of PCM was verified via comparing with conventional longitudinal fins within the same design limitations of fin material and volume usage. Optimization of the fin geometric parameters including the pitch, numb
... Show More