The hydrodynamics of a co-current down flow bubble column has been investigated with air – water system. A Perspex bubble column of 5cm in diameter and 1.5m height is used as a test contactor using nozzles of 7, 8 and 9 mm diameter for air-water distributing. The column is provided with three electro-resistivity needle probes for bubble detection.
Experimental work is carried out with air flow rates from 0.09 to 0.45 m3/hr and liquid flow rates from 0.65 to 1.1m3/hr in order to study the effects of superficial gas velocity, nozzle diameter and liquid flow rate on the characteristics of hydrodynamic interactions viz. gas hold up, bubble diameter and bubble velocity by using two technical methods, direct height measurements for air-water mixture in the column and resistivity probe techniques.
Gas hold up is found to be progressively increased with increasing superficial gas velocity and with decreasing liquid flow rate. Lower gas hold up is obtained with smaller nozzle diameter. However, gas hold up in two-phase zone is considerably higher than the corresponding value in mixing zone.
The mean bubble velocity is increased with increasing superficial gas velocity, liquid flow rate and nozzle diameter for both mixing and two phase zones. Experimental data are found to be fairly fitted with the Drift Flux model of Zuber and Findly.
The bubble diameter is considerably increased with increasing superficial gas velocity and with decreasing liquid flow rate, whereas it is slightly influenced by nozzle diameter. However, the bubbles in two-phase zone are relatively bigger than those observed in mixing zone. Finally, mathematical correlations have been developed from the experimental data to describe the gas hold up and bubble velocity in the uniform two-phase zone.
There is an interesting potential for the use of GFRP-pultruded profiles in hybrid GFRP-concrete structural elements, either for new constructions or for the rehabilitation of existing structures. This paper provides experimental and numerical investigations on the flexural performance of reinforced concrete (RC) specimens composite with encased pultruded GFRP I-sections. Five simply supported composite beams were tested in this experimental program to investigate the static flexural behavior of encased GFRP beams with high-strength concrete. Besides, the effect of using shear studs to improve the composite interaction between the GFRP beam and concrete as well as the effect of web stiffeners of GFRP were explored. Encasing the GFRP
... Show MoreAdvancing the multi-scale performance of asphalt pavements requires innovative binder modifications that address limitations in rutting resistance, fatigue resistance, and durability across the binder, mixture, and structural levels. This study evaluates the performance of asphalt cement, mixtures, and pavement systems modified with a combination of polyethylene (PE) and carbon nanotubes (CNTs). The binder was modified using 4% PE and varying CNT contents (0.5%, 1%, 1.5%, and 2% by weight of the modified binder). Binder performance was assessed through conventional and rheological tests, including penetration, softening point, viscosity, performance grade (PG) evaluation, and master curve analysis. Mixture-level performance was eval
... Show MoreThe objective of this work is to investigate the performance of a conventional three phase induction motor supplied by unbalanced voltages. An effort to study the motor steady state performance under this disturbance is introduced. Using per phase equivalent circuit analysis with the concept of symmetrical components approach, the steady state performance is theoretically calculated. Also, a model for the induction motor with the MATLAB/Simulink SPS tools has been implemented and steady state results were obtained. Both results are compared and show good correlation as well. The simulation model is introduced to support and enhance electrical engineers with a complete understanding for the steady state performance of a fully loaded induc
... Show MoreHard-grade asphalt binders, such as AC 20–30, offer excellent resistance to permanent deformation but are inherently brittle, making them highly susceptible to fatigue and low-temperature cracking. While polymer modification addresses these issues, virgin polymers remain expensive. Despite the growing interest in recycled plastics, the rheological impact of complex waste streams, specifically polyvinyl chloride (PVC) derived from flex banners containing plasticizers, on excessively stiff binders within the complete Superpave Performance Grading (PG) framework remains critically underexplored. This study introduces a novel valorization approach by utilizing solvent-extracted flex banner waste (WPVC) as a dual-action modifier. It leverages
... Show MoreLarge language models (LLMs) are a rapidly evolving class of artificial intelligence with significant potential in clinical healthcare. Despite accelerating adoption, rigorous systematic evidence on clinical utility, patient safety, and implementation feasibility remains fragmented. To systematically review LLM applications across clinical domains, evaluate performance with appropriate contextual caveats, characterize implementation barriers, and identify ethical and regulatory considerations. Scientific databases were searched from January 2020 to January 2025. Studies evaluating transformer-based LLMs (≥10M parameters) in clinical settings were eligible. Data were independently double-extracted; quality was assessed using QUADAS-2, RE-A
... Show MoreField trial was conducted with the aim of utilizing extract of allelopathic crop to reduce the use of synthetic herbicides in wheat fields. Sorghum extract at 12 L /ha, sunflower extract at 12 L /ha, combination of sorghum and sunflower extracts at 12 L /ha and chevalier at 25, 50 and 100% of recommended dose were applied alone or in combination with each other. Weed free and weedy check treatments were included for comparison. The experiment was conducted in a randomized complete block design with three replications. The results showed that the recommended dose of chevalier treatment recorded lowest means of weed density 15.7, 23.7, 25.3 and 27.9 weeds m-2and weeds dry weight 13.4, 16.4, 23.3 and 29.2 g m-2 and gave
... Show MoreAn in-depth experimental study of the matrix effect of antifreeze (ethylene glycol) and water contamination of engine oil through FT-IR spectroscopy. With a comparison of the percent by volume concentration of contaminated fresh 15W-40 engine oil, there appeared to be a noticeable reduction in the O–H stretching signal in the infrared spectrum when ethylene glycol based antifreeze was included as a contaminant. The contaminants of distilled water, a 50/50 mixture of water and commercial ethylene glycol antifreeze, and straight ethylene glycol antifreeze were compared and a signal reduction in the O–H stretch was clearly evident when glycol was present. Doubling the volume of the 50/50 mixture as compared to water alone still res
... Show MoreThe aim of this study was the discrimination of Salmonella isolated from chicken and their feed and drinking water for the epidemiological control of salmonellosis. Totally, 289 samples, including 217 chicken cloaca swabs, 46 water, and 26 feed samples were collected from five different farms in Karbala governorate, Iraq. Conventional bacteriology tests, API 20E, Vitek 2, and serology were used for bacterial identification. Random amplified polymorphic DNA (RAPD)-polymerase chain reaction (PCR) was applied to analyze the genetic relationships among Salmonella isolates. The isolation rate of Salmonella spp. was 21.1% (61/289). While the water samples constituted the highest rate (30.4%), a rate of
... Show MoreThe role of filamentous bacteria represented by Streptomycessp was studied as biological treatment for activated sludge AL- Restomia treatment unit in Baghdad city. The result shows reducing in phosphate concentration where apprise in started entrance the treatment unit 12.083 mg/L fast the unit stages reached to 8.426 mg /L where nitrate concentration apprises 3.59 mg/l and ending in 2.43 mg/L The concentration of ammonia apprises 1358 mg/L and reached to 140 mg/L. also the TDS concentration reduced from 1426 to 1203 mg/L where nutrient which represented (SO4, Mg, Ca, Na, K) reduced by range 30.883- 23.337 , 194- 121 , 440- 321 , 109.03- 101.53 and 16.85- 15.4mg/L respectively COD reduce from427.263- 82mg/L with absorbance0.018- 0.027
... Show More