Preferred Language
Articles
/
ijcpe-295
Removal of SO2 over Modified Activated Carbon in Fixed Bed Reactor: I, Effect of Metal Oxide Loadings and Acid Treatment
...Show More Authors

 

The removal of SO2 from simulated gas stream (SO2 + air) in a fixed bed reactor using Modified Activated Carbon (MAC) catalysts was investigated. All the experiments were conducted at atmospheric pressure, initial SO2 concentration of 2500 ppm and bed temperature of 90oC. MAC was prepared by loading a series of nickel and copper oxides 1, 3, 5, 7, and 10 wt% on AC. In some of the experimental runs, the original activated carbon was pretreated with two different concentrations of nitric acid 10 and 45 wt%. The results showed that the SO2 removal efficiency, breakthrough time (τ0.05) and sorption capacity increase with increasing metal oxides loadings up to a value of 7 wt% beyond which the desulfurization performance decreases. The pretreatment of the original AC with HNO3 enhanced the removal efficiency of SO2. The copper supported catalysts showed higher flue gas desulfurization activity as compared to the nickel supported catalysts.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Jan 31 2020
Journal Name
Sains Malaysiana
Adsorption of Para Nitro-phenol by Activated Carbon Produced from Alhagi
...Show More Authors

View Publication
Scopus (14)
Crossref (8)
Scopus Clarivate Crossref
Publication Date
Sun Sep 01 2019
Journal Name
Al-khwarizmi Engineering Journal
Adsorption of Heavy Metals from Aqueous Solution onto Sawdust Activated Carbon
...Show More Authors

In this study, sawdust as a cheap method and abundant raw material was utilized to produce active carbon (SDAC). Physiochemical activation was utilized where potassium hydroxide   used as a chemical activating agent and carbon dioxide was used as a physical activating agent. Taguchi method of experimental design was used to find the optimum conditions of SDAC production. The produced SDAC was characterized using SEM to investigate surface morphology and BET to estimate the specific surface area. SDAC was used in aqueous lead ions adsorption. Adsorption process was modeled statistically and represented by an empirical model. The highest specific surface area of SDAC was 688.3 m2/gm. Langmuir and Freundlich isotherms were used to

... Show More
View Publication Preview PDF
Publication Date
Sun Jun 07 2009
Journal Name
Baghdad Science Journal
The adsorption-desorption process as a method for separation of nitrogen-carbon dioxide gas mixture using activated carbon
...Show More Authors

Gas adsorption phenomenon on solid surface has been used as a mean in separation and purification of gas mixture depending on the difference in tendencies of each component in the gas mixture to be adsorbed on the solid surface according to its behaviour. This work concerns to study the possibilities to separate the gas mixture using adsorption-desorption phenomenon on activated carbon. The experimental results exhibit good separation factor at temperature of -40 .

View Publication Preview PDF
Crossref
Publication Date
Mon Jul 10 2023
Journal Name
Journal Of Engineering
Removal of Hexavalent Chromium from Aqueous Solutions by Adsorption on Thermally Modified and Non-Modified Eggshells
...Show More Authors

Removal of heavy metals from waste water has received a great deal of attention. The compare Cr
(VI) adsorption characteristics removing from wastewater by using thermally modified and non-modified
eggshells were examined

View Publication Preview PDF
Crossref
Publication Date
Fri Jul 21 2023
Journal Name
Journal Of Engineering
Removal of Copper Ions onto Walnut Shells by Using Batch and Continuous Fluidized Bed
...Show More Authors

An agricultural waste (walnut shell) was undertaken to remove Cu(II) from aqueous solutions in batch and continuous fluidized bed processes. Walnut shell was found to be effective in batch reaching 75.55% at 20 and 200 rpm, when pH of the solution adjusted to 7. The equilibrium was achieved after 6 h of contacting time. The maximum uptake was 11.94mg/g. The isotherm models indicated that the highest determination coefficient belongs to Langmuir model. Cu (II) uptake process in kinetic rate model followed the pseudo-second-order with determination coefficient of 0.9972. More than 95% of the Cu(II) were adsorbed on the walnut shells within 6 h at optimum agitation speed of 800 rpm. The main functional groups responsible for biosorption of

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Apr 01 2015
Journal Name
Journal Of Engineering
Competitive Removal of Cu2+, Cd2+and Ni2+by Iron Oxide Nanoparticle (Fe3O4)
...Show More Authors

A competitive adsorption of Cu2+, Ni2+, and Cd2+ ions from a synthetic wastewater onto nanomaterial was studied.(Fe3O4) nanoparticles obtained from US Research Nanomaterials, Inc., Houston, TX 77084, (USA), was used as nanosorbent. Experimental parameters included pH, initial metal concentrations, and temperature were studied for nanosorbent. The uptake capacity 11.5, 6.07 and 11.1 mg/g for Cu2+, Ni2+and Cd2+, respectively, onto nanosorbent . The optimum pH values was 6 and the contact time was 50 min. for Cu2+, Ni2+and Cd2+, respectively. The equilibrium isotherm for

... Show More
View Publication Preview PDF
Publication Date
Tue Mar 30 2010
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
The Inhibition Effect of Peach Juice on Corrosion of Low Carbon Steel in Hydrochloric Acid at Different Temperatures
...Show More Authors

The corrosion inhibition of low carbon steel in1N HCl solution in the presence of peach juice at temperature (30,40,50,and 60)°C at concentration ( 5, 10, 20, 30, 40and 50 cm3/L)were studied using weight loss and polarization techniques. Results show that the inhibition efficiency was increased with the increase of inhibitor concentration and increased with the increase of temperature up to 50ºC ,above 50ºC (i.e. at 60 ºC) the values of efficiency decreases. Activation parameters of the corrosion process such as activation energies, Ea, activation enthalpies, ΔH, and activation entropies, ΔS, were calculated. The adsorption of inhibitor follows Langmuir isotherm. Maximum inhibition efficiency obtained was a bout 91% at 50ºC in the

... Show More
View Publication Preview PDF
Publication Date
Sat Dec 31 2016
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Corrosion Inhibition of Carbon Steel in Hydrochloric Acid under Dynamic Conditions
...Show More Authors

In this work, studying the effect of ethylenediamine as a corrosion inhibitor was investigated for carbon steel in aerated HCl solution in range of 0.1-1N under dynamic conditions, i.e., rotational velocity of 400–1200 rpm in the temperature range 35 – 65 ºC.  Weight loss method was employed in absence and presence of the inhibitor as an adsorption type in concentration range 1000 – 5000 ppm using rotating cylinder specimens. The experimental results showed that corrosion rate in absence and presence of inhibitor is increased with increasing temperature, rotational velocity and concentration of acid. It is decreased with increasing inhibitor concentration for the whole range of temperature, rotational velocity and concentrati

... Show More
View Publication Preview PDF
Publication Date
Mon Dec 30 2013
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Kinetic Study and Simulation of Oleic Acid Esterification over Prepared NaY Zeolite Catalyst
...Show More Authors

Esterification considers the most important reaction in biodiesel production. In this study, oleic acid was used as a suggested feedstock in order to study and simulate production of biodiesel. The batch esterification reaction of oleic acid was carried out at various operating conditions; temperature from 40 to 70 °C, ethanol to oleic acid molar ratio from 3/1 and 6/1 and a reaction time up to 180 min.
The catalyst used was prepared NaY zeolite, which is added to the reaction mixture as 2, 5 and 10 wt.% of oleic acid.
The results show that the optimum conditions, gives 0.81 conversion of oleic acid, were 6/1 molar ratio of ethanol/oleic acid, 5 wt.% NaY relative to initial oleic acid, 70°C and 60 minutes. The activation energy o

... Show More
View Publication Preview PDF
Publication Date
Mon Mar 01 2021
Journal Name
Energy Ecological Environment
Removal of pathogenic bacteria from synthetic contaminated water using packed bed silver nanoparticle-coated substrates
...Show More Authors

In this study, a packed bed was used to remove pathogenic bacteria from synthetic contaminated water. Two types of packing material substrates, sand and zeolite, were used. These substrates were coated with silver nanoparticles (AgNPs), which were prepared by decomposition of Ag ions from AgNO3 solution. The prepared coated packings were characterized using scanning electron microscopy, energy-dispersive X-ray spectroscopy and transmission electron microscopy. The packed column consisted of a PVC cylinder of 2 cm diameter and 20 cm in length. The column was packed with silver nanoparticlecoated substrates (sand or zeolite) at a depth of 10 cm. Four types of bacteria were studied: Escherichia coli, Shigella dysenteriae, Pseudomonas aerugi

... Show More
Crossref (5)
Crossref