In this work, corrosion parameters were evaluated using potentiodynamic polarization curves. In order to determine corrosion parameters of potential and current density of the interesting metal, carbon steel, environmental conditions of external corrosion of buried carbon steel pipeline in Iraqi soil were prepared in the laboratory using simulated prepared conditions. Solutions of sodium chloride at different concentrations (300, 1100, 1900, 2700, and 3500 ppm) were used. pH of solution were acidic at pH =5, and alkaline at pH = 9. Laboratory conditions were similar to those of Iraqi soil where the pipelines were buried. Temperature was constant at 20 °C. Potentiodynamic polarization curves, of potential vs. log current density, were obtained using M Lab Multi-Channel Potentiostat/Galvanostat. The carbon steel coupon (ASTM A179-84A) was used as the studied metal. The results of this work reveal the behavior of carbon steel in external corrosion conditions under Iraqi soil. The rate of corrosion, of carbon steel, increases with the increase in chloride concentration in solution. As pH changes from acidic to alkaline medium, the rate of corrosion decreases.
Background: Hyperthyroidism is a serious public concern, due the continuous increase in its prevalence and its impact on the mortality rates. Autoimmune hyperthyroidism is seen as a thyroid gland problem. Pro-inflammatory cytokines are crucial for the growth and development of hyperthyroidism, it was shown that the level of several pro-inflammatory cytokines were higher in the hyperthyroidism patients. Objective: This work was aimed to assessment the concentration of certain cytokine in hyperthyroid patients. Materials and Methods: Sixty hyperthyroidism patients and 30 healthy individuals with age range from (30-65) years old were enrolled in this study through their presence at the National Center for Diabetes Treatment and Research in Bag
... Show MoreIn the present work, the surface properties of mixed binary surfactants containing sodium dodecylbenzene sulfate (SDBS) and Tween 80 (TW80) surfactants in aqueous solutions were studied at temperature 293 K using surface tension measurements. The critical micelle concentration (cmc) magnitude for both individual surfactants and their mixtures were established the obtained results revealed that the magnitude of cmc of the mixtures are less than the magnitude of individual surfactants and decrease with the increase in Tween 80 percent in solution which indicate the nonideal mixing of the two surfactants. The values of molecular interaction parameters and the mole fraction of surfactants in the micelle (X1) were calculated
... Show MoreWater injection equipments such as pipelines, which are used in the second recovery of oil in the Al-Ahdeb wells, suffer from the corrosion in water during maintaining vacuum deoxygenated tower that used to decrease concentration of the dissolved oxygen gas in the water from 6.2-9.1 ppm to o.5 ppm. This study involved calculation the corrosion rates of the internal surfaces of the
pipelines either during operation of the vacuum unit or when the tower out of operation. Finally, find the solution by one of the following suggestions. In the first suggestion removal of the dissolved O2 from water is achieved by increasing the dosage of the oxygen scavenger (sodium sulphite). The second suggestion involves removing the dissolved O2 from w
Water injection equipments such as pipelines, which are used in the second recovery of oil in the Al-Ahdeb wells, suffer from the corrosion in water during maintaining vacuum deoxygenated tower that used to decrease concentration of the dissolved oxygen gas in the water from 6.2-9.1 ppm to o.5 ppm. This study involved calculation the corrosion rates of the internal surfaces of the pipelines either during operation of the vacuum unit or when the tower out of operation. Finally, find the solution by one of the following suggestions. In the first suggestion removal of the dissolved O2 from water is achieved by increasing the dosage of the oxygen scavenger (sodium sulphite). The second suggestion involves re
... Show MoreBackground: Hyperthyroidism refers to overactive of thyroid gland leading to excessive synthesis of thyroid hormones and accelerated metabolism in the peripheral tissue. Objective: The aim of this study is to evaluate a new member of the IL-1 super family of cytokines interleukin-33(IL-33) levels in serum .in order to evaluate its utility as clinical bio marker of autoimmune disease (i.e. hyperthyroidism) Methods: The present study was conducted on 30 patients from the Iraqi female patients with hyperthyroidism attending Baghdad teaching hospital, in addition to 30 healthy controls. All subjects were (35-65) years old. Parameters measured in the sera of patients and healthy groups, were interleukin -33 (IL-33), Thyroxin (T4), Thyroxin (T3)
... Show MoreKE Sharquie, R Hayani, J Al-Rawi, A Noaimi, SH Radhy, CLINICAL AND EXPERIMENTAL RHEUMATOLOGY, 2010
Activated carbon loading with metals oxides is new adsorbents and catalyst, which seem very promising for desulfurization process. The present study deals with the preparation of three metals oxides loaded on activated carbon (AC). The tri composite of ZnO/NiO/CoO/AC was characterized by X-Ray Diffraction (XRD), X-Ray florescence (XRF), N2 adsorption for BET surface area, pore volume and Atomic Force Microscopy (AFM). The effect of calcination temperature is investigated. The best calcination temperature is 250oC based on the presence of phase, low weight loss and keep at high surface area. The surface area and pore volume of prepared tri composite are 932.97m2/g and 0.6031cm3/g respec
... Show MoreThe corrosion behavior of carbon steel at different temperatures 100,120,140 and 160 Cͦ under different pressures 7,10 and 13 bar in pure distilled water and after adding three types of oxygen scavengers Hydroquinone, Ascorbic acid and Monoethanolamine in different concentrations 40,60 and 80 ppm has been investigated using weight loss method. The carbon steel specimens were immersed in water containing 8.2 ppm dissolved oxygen (DO) by using autoclave. It was found that corrosion behavior of carbon steel was greatly influenced by temperature with high pressure. The corrosion rate decreases, when adding any one of oxygen scavengers. The best results were obtained at a concentration of 80 ppm of each scavenger. It was observed that
... Show MoreThe study area soils suffer from several problems appear as tkhesvat and cracks in the roads and waterlogging which reduces the susceptibility of soil to withstand pressure, this study was conducted on the soil of the Karkh district based on field study that included (6) samples of soil physical analyses contain different ratios of (mud, sand, silt) as percentages (52%, 45%, 3 #) respectively, and liquidity limit rate (39%) Stroke rate plasticity was (20.6%) The rate coefficient of plasticity total (19.2%)0