The effect of three ionic liquids viz., 1-hexyl-3-methylimidazolium tetrafluoroborate (ILE), 1-hexyl-3-metylimidazolium hexafluorophosphate (ILF) and 1-octyl-3-methylimidazolium tetrafluoroborate (ILG) when used as surfactants on the performance of dissolved air floatation (DAF) was investigated.

   Experiments were conducted at a temperature of 30-35 ºC, 10ppm ferric chloride as coagulant, 50% recycle ratio, pH 8, and 10 minutes treatment time  to find oil and grease (OG) and turbidity removal efficiencies at saturation pressure (2-6) bar.

ILs were used at concentration of 50 µl/liter of treated water in two positions in DAF system; the saturation vessel and the treatment tank. The performance using ILs in the saturation vessel were better than that in treatment tank because  ILs reduced the surface tension of water, which lead to an increase in the solubility of air in water and eventually increase the microbubble formation.  The OG removal efficiency using ILG as an efficient surfactant in saturation vessel was higher than that in the treatment tank and higher than other ILs (ILG>ILF>ILE). The removal efficiency reached about 90% at a saturation pressure of 5 bar, and 85% at 3 bar, which reduces the operation costs.  The treated water oil concentration at 3bar was 9.5 ppm, which meets the Iraqi pre-disposal regulatory limit.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Mar 09 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Improve Performance of Solar Cell by using Grooves which Have Semicircular Shape on The Surface by using Program (ZEMAX)
...Show More Authors

 In this work silicon solar cell has been used with semicircular grooves to improve its efficiency by reducing reflection of rays and increasing optical path through the cell. Software program for optical design (zemax) has been used by ray tracing mode to evaluate prototype efficiency when using detector beneath the cell. The prototype has aspect ratio (A.R=0.2) which is the best efficiency at incident angle (Ï´=0ͦ) and the best acceptance angle (Ï´=50ͦ). 

View Publication Preview PDF
Publication Date
Sat Sep 30 2023
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Performance of Electro-Fenton Process for Phenol Degradation Using Nickel Foam as a Cathode
...Show More Authors

Toxic substances have been released into water supplies in recent decades because of fast industrialization and population growth. Fenton electrochemical process has been addressed to treat wastewater which is very popular because of its high efficiency and straightforward design. One of the advanced oxidation processes (AOPs) is electro-Fenton (EF) process, and electrode material significantly affects its performance. Nickel foam was chosen as the source of electro-generated hydrogen peroxide (H2O2) due to its good characteristics. In the present study, the main goals were to explore the effects of operation parameters (FeSO4 concentration, current density, and electrolysis time) on the catalytic perform

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sat Sep 30 2023
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Performance of Electro-Fenton Process for Phenol Degradation Using Nickel Foam as a Cathode
...Show More Authors

Toxic substances have been released into water supplies in recent decades because of fast industrialization and population growth. Fenton electrochemical process has been addressed to treat wastewater which is very popular because of its high efficiency and straightforward design. One of the advanced oxidation processes (AOPs) is electro-Fenton (EF) process, and electrode material significantly affects its performance. Nickel foam was chosen as the source of electro-generated hydrogen peroxide (H2O2) due to its good characteristics. In the present study, the main goals were to explore the effects of operation parameters (FeSO4 concentration, current density, and electrolysis time) on the catalytic performance that was optimized by r

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sun Dec 01 2019
Journal Name
Journal Of Engineering Science And Technology (jestec)
Water Quality Assessment And Total Dissolved Solids Prediction For Tigris River In Baghdad City Using Mathematical Models
...Show More Authors

Total dissolved solids are at the top of the parameters list of water quality that requires investigations for planning and management, especially for irrigation and drinking purposes. If the quality of water is sufficiently predictable, then appropriate management is possible. In the current study, Multiple Linear Regression (MLR) and Artificial Neural Network (ANN) models were used as indicators of water quality and for the prediction of Total Dissolved Solids (TDS) along the Tigris River, in Baghdad city. To build these models five water parameters were selected from the intakes of four water treatment plants on the Tigris River, for the period between 2013 and 2017. The selected water parameters were Total Dissolved Solids (TDS

... Show More
Publication Date
Sun Aug 01 2021
Journal Name
Telkomnika
Proposed different relay selection schemes for improving the performance of cooperative wireless networks
...Show More Authors

Scopus (4)
Crossref (2)
Scopus Crossref
Publication Date
Mon Sep 01 2014
Journal Name
Al-khwarizmi Engineering Journal
Experimental Performance of a Finned-tube Silica Gel Adsorption Chiller for Air-Conditioning Application
...Show More Authors

This work presents the construction of a test apparatus for air-conditioning application that is flexible in changing a scaled down adsorbent bed modules. To improve the heat and mass transfer performance of the adsorbent bed, a finned-tube of the adsorbent bed heat exchanger was used. The results show that the specific cooling power (SCP) and the coefficient of performance (COP) are 163 W/kg and 0.16, respectively, when the cycle time is 40 min, the hot water temperature is 90oC, the cooling water temperature is 30oC and the evaporative water temperature is 11.4oC.

View Publication Preview PDF
Publication Date
Fri Mar 01 2019
Journal Name
Al-khwarizmi Engineering Journal
Removal of Dissolved Trivalent Chromium Ions from Contaminated Wastewater using Locally Available Raw Scrap Iron-Aluminum Waste
...Show More Authors

The present study is to investigate the possibility of using wastes in the form of scrap iron (ZVI) and/ or aluminum ZVAI for the detention and immobilization of the chromium ions in simulated wastewater. Different batch equilibrium parameters such as contact time (0-250) min, sorbent dose (2-8 g ZVI/100 mL and 0.2-1 g ZVAI/100 mL), initial pH (3-6), initial pollutant concentration of 50 mg/L, and speed of agitation (0-250) rpm were investigated. Maximum contaminant removal efficiency corresponding to (96 %) at 250 min contact time, 1g ZVAI/ 6g ZVI sorbent mass ratio, pH 5.5, pollutant concentration of 50 mg/L initially, and 250 rpm agitation speed were obtained.

The best isotherm model for the batch single Cr(III) uptake by ZVI

... Show More
View Publication Preview PDF
Crossref (12)
Crossref
Publication Date
Tue Aug 01 2017
Journal Name
Journal Of Natural Gas Science And Engineering
Recovery of mono-ethylene glycol by distillation and the impact of dissolved salts evaluated through simulation of field data
...Show More Authors

View Publication
Scopus (41)
Crossref (40)
Scopus Clarivate Crossref
Publication Date
Thu Sep 01 2022
Journal Name
Civil Engineering And Architecture
Strengthening AL-Kadhimin Tilted Minaret by Using a System of Micro-piles
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Sun Dec 01 2024
Journal Name
Anbar Journal Of Agricultural Sciences
IMPROVING THE QUALITY OF POTATO MINI TUBERS BY SUSTAINABLE CULTIVATION
...Show More Authors

View Publication
Scopus (5)
Scopus Crossref