Preferred Language
Articles
/
ijcpe-235
Investigation of Binary Solvents Performance for Regeneration of Iraqi 15W- 40 Waste Lubricant
...Show More Authors

The aim of this study was to investigate the effectiveness of binary solvent for regeneration of spent lubricating oil by extraction-flocculation process. The regeneration was investigated by bench scale experiments by using locally provided solvents (Heavy Naphtha, n-Butanol, and iso-Butanol). Solvents to used oil, mixing time, mixing speed and temperatures were studied as operating parameters. The performance on three estimated depended key parameters, namely the percentage of base oil recovered (Yield), percent of oil loss (POL), and the percent of sludge removal (PSR) were used to evaluate the efficiency of the employed binary solvent on extraction process. The best solvent to solvent ratio for binary system were 30:70 for Heavy Naphtha : n-Butanol (N:n-But) and Heavy Naphtha : iso-Butanol (N:iso-But). The optimum solvent to oil ratio or critical clarifying ratio (CCR) were 3.4, and 3.8 for N : n-But, and N : iso-But respectively. The optimized operating mixing time, mixing speed, and temperature which result in, maximum recovered base oil (87.75% and 88.88%), minimum oil losses (8.46% and 3.62%), and maximum sludge removal (5.63% and 6.12%), were (45 min, 700 rpm, 35 oC), and (30 min, 700 rpm, 35 oC ) for N:n-But, and N:Iso-But respectively.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Mar 03 2021
Journal Name
Innovative Infrastructure Solutions
Experimental investigation of a new sustainable approach for recycling waste styrofoam food containers in lightweight concrete
...Show More Authors

View Publication
Scopus (5)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Thu Mar 02 2023
Journal Name
East European Journal Of Physics
Investigation of the Impact of Glass Waste in Reactive Powder Concrete on Attenuation Properties for Bremsstrahlung Ray
...Show More Authors

Reactive Powder Concrete (RPC) is one of the most advanced recent high compressive strength concrete. This work explored the effects of using glass waste as a fractional replacement for fine aggregate in reactive powder concrete at levels of 0%, 25%, 50%, and 100%. Linear and mass attenuation coefficients have been calculated as a function of the sample's thickness and bremsstrahlung energy. These coefficients were obtained using energy selective scintillation response to bremsstrahlung having an energy ranging from (0.1-1.1) MeV. In addition, the half-value thickness of the samples prepared has been investigated. It was found that there is a reversal association between the attenuation coefficient and the energy of the bremsstrahlu

... Show More
View Publication
Scopus (2)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Mon Apr 10 2023
Journal Name
The European Physical Journal Plus
Improved performance of D149 dye-sensitized ZnO-based solar cell under solvents activation effect
...Show More Authors

View Publication
Crossref
Publication Date
Sun Jun 01 2025
Journal Name
Cleaner Waste Systems
Performance enhancement of natural asphalt using waste-derived modifiers: Sugarcane molasses and waste engine oil
...Show More Authors

The growing demand for sustainable and high-performance asphalt binders has prompted the exploration of waste-derived modifiers. This study investigates the performance enhancement of Natural Asphalt (NA) using Sugarcane Molasses (SM) and Waste Engine Oil (WEO). The modified blends were prepared by partially replacing 50 % NA with varying proportions of SM and WEO ranging from 10 % to 40 % of the total weight of NA. Comprehensive testing was conducted, including penetration, softening point, ductility, viscosity, Bending Beam Rheometer (BBR), Multiple Stress Creep Recovery (MSCR), Energy Dispersive X-ray Spectroscopy (EDX), Fourier Transform Infrared (FTIR) spectroscopy, and Scanning Electron Microscopy (SEM). The results demonstrated that

... Show More
View Publication
Crossref
Publication Date
Wed Jun 01 2022
Journal Name
Baghdad Science Journal
Design and Performance Investigation of a Solar- Powered Biological Greywater Treatment System in the Iraqi Climate
...Show More Authors

            The increase in population resulted in an increase in the consumption of water. The present work investigates the performance of a recycling solar- powered greywater treatment system for the purposes of irrigation, used to reduce the amount of waste grey water and reduce electricity consumption and reduce the costs of constructing large scale water treatment plants. The system consumes about 3814W per hour and provides water treatment about 1.4 m3 per day. The proposed system is designed to    residential, office and governmental buildings application. Tests are conducted in an office building at the Ministry of Science and Technology site in Baghdad. Laboratorial water samples testing analyses are co

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Clarivate Crossref
Publication Date
Mon May 01 2023
Journal Name
Ain Shams Engineering Journal
Neural network modeling of rutting performance for sustainable asphalt mixtures modified by industrial waste alumina
...Show More Authors

Scopus (16)
Crossref (10)
Scopus Clarivate Crossref
Publication Date
Wed Jun 15 2022
Journal Name
Malaysian Journal Of Science
INVESTIGATION OF FAST NEURON ATTENUATION COEFFICIENTS FOR SOME IRAQI BUILDING MATERIALS
...Show More Authors

This research aims to improve the radiation shielding properties of polymer-based materials by mixing PVC with locally available building materials. Specifically, two key parameters of fast neutron attenuation (removal cross-section and half-value layer) were studied for composite materials comprising PVC reinforced with common building materials (cement, sand, gypsum and marble) in different proportions (10%, 30% and 50% by weight). To assess their effectiveness as protection against fast neutrons, the macroscopic neutron cross-section was calculated for each composite. Results show that neutron cross-section values are significantly affected by the reinforcement ratios, and that the composite material PVC + 50% gypsum is an effect

... Show More
View Publication
Scopus (1)
Scopus Crossref
Publication Date
Mon Jan 01 2018
Journal Name
Asian Journal Of Ournal Of Chemistry
Extraction of Ocimum basillicum Oil by Solvents Methods
...Show More Authors

The extraction of Basil oil from Iraqi Ocimum basillicum leaves using n-hexane and petroleum ether as organic solvents were studied and compared. The concentration of oil has been determined in a variety of extraction temperatures and agitation speed. The solvent to solid ratio effect has been studied in order to evaluate the concentration of Ocimum basillicum oil. The optimum experimental conditions for the oil extraction were established as follows: n-hexane as organic solvent, 60 °C extraction temperature, 300 rpm agitation speed and 40:1mL:g amount of solvent to solid ratio.

View Publication
Scopus (9)
Crossref (7)
Scopus Crossref
Publication Date
Fri Mar 28 2025
Journal Name
Iraq Journal Of Market Research And Consumer Protection
Study of the qualitative characteristics of oils derived from fish waste running Asian Silurus triostequs and use of organic solvents in certain food systems
...Show More Authors

View Publication
Publication Date
Sat Dec 02 2023
Journal Name
Journal Of Engineering
Simulation and Experimental Investigation of Performance and Flow Behavior for Steam Ejector Refrigeration System
...Show More Authors

The ejector refrigeration system is a desirable choice to reduce energy consumption. A Computational Fluid Dynamics CFD simulation using the ANSYS package was performed to investigate the flow inside the ejector and determine the performance of a small-scale steam ejector. The experimental results showed that at the nozzle throat diameter of 2.6 mm and the evaporator temperature of 10oC, increasing boiler temperature from 110oC to 140oC decreases the entrainment ratio by 66.25%. At the boiler temperature of 120oC, increasing the evaporator temperature from 7.5 to 15 oC increases the entrainment ratio by 65.57%. While at the boiler temperature of 120oC and

... Show More
View Publication Preview PDF
Crossref (1)
Crossref