Preferred Language
Articles
/
ijcpe-225
Kinetic of Disinfection reaction by Sodium Hypochlorite Solution
...Show More Authors

The present studier aims to study the kinetic of reaction at different experimental conditions depending on coliform bacteria concentration and hypochlorite ion. The effects that had been investigated were different of sodium hypochlorite doses, contact time, pH and temperature (20, 29, 37) o C. The water samples were taken from Al-Wathba water treatment plant in Risafa side of Tigris River in Baghdad. The biological tests included the most probable number (M.P.N) for indicating the concentration of coliform bacteria with different contact times and the total plate count (T.P.C) for indicating the amount of colonies for general bacteria. The iodimetry method (chemical test) was used for indicating the concentration of hypochlorite ion with different contact times. Different models were examined to fit the experimental data including the kinetics power law (first and second order) and Selleck model. It was found that the Selleck model fitted well the experimental data in which degree of Selleck model was equal to two and the rate constants was 1.3791 x 10-5 L / (mole min) at 20o C, 3.0806 x 10-5 L / (mole min) at 29oC, and 5.738 x 10-5 L / (mole min) at 37o C.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Jan 01 2019
Journal Name
Indian Journal Of Public Health Research & Development
Spectrophotometric Determination of Nifedipine in Pharmaceutical Tablets Using Batch and Flow Injection Method Via Diazotization Coupling Reaction
...Show More Authors

View Publication
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Tue Sep 11 2018
Journal Name
Iraqi Journal Of Physics
An experimental cross-section measurement of 10B(n,α)7Li reaction on counting alpha particles track density
...Show More Authors

The present work determines the particle size based only on the number of tracks detected in a cluster created by a hot particle on the CR-39 solid state nuclear track detector and depending on the exposure time. The mathematical model of the cross section developed here gives the relationship between alpha particle emitting from the (n, α) reaction and the number of tracks created and distribution of tracks created on the surface of the track detector. In an experiment performed during this work, disc of boron compound (boric acid or sodium tetraborate) of different weights were prepared and exposed to thermal neutron from the source. Chemical etching is processes of path formation in the detector, during which a suitable etching solut

... Show More
View Publication
Crossref
Publication Date
Thu Jan 01 2009
Journal Name
Ibn Al- Haitham J. Fo R Pure & Appl. Sci
Multiple Mixing Ratios of Gamma Rays Erγ)nEr(n, From 168 168 Reaction  Using a2 – Ratio Method
...Show More Authors

The -mixing of  - transition in Er 168 populated in Er)n,n(Er 168168  reaction is calculated in the present work by using a2- ratio method. This method has used in previou studies [4, 5, 6, 7] in case that the second transition is pure or for that transition which can be considered as pure only, but in one work we applied this method for two cases, in the first one for pure transition and in the 2nd one for non pure transitions. We take into accunt the experimental a2- coefficient for p revious works and -values for one transition only [1]. The results obtained are, in general, in agood agreement within associated errors, with those reported previously [1], the discrepancies that occur are due to inaccuracies existing

... Show More
Publication Date
Thu Jun 23 2022
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Flow Injection Spectrophotometric Technique for Determining of Genistein in Pure and Supplements Formulations Through Diazotization Coupling Reaction
...Show More Authors

Genistein (GEN) is The major isoflavone found in soybeans, has a number of cardiovascular health benefits, Postmenopausal syndrome and osteoporosis. A direct flow injection analysis method for estimation of (GEN) in pure and supplements formulation . This system is based on diazotization coupling reactions between procaine penciline (PR) and genistein in basic medium, they formed yellow dyes have maximum absorption at 416 nm. Calibration curve were constructed over different GEN concentrations, linearity for GEN was 10-100 µg.mL-1 and detection limits of 1.51 ?g/mL. In the FIA technique, all analytical factors were analyzed and optimized. The established method was successfully used to determine GEN in the formulations of its supplement

... Show More
View Publication Preview PDF
Scopus (5)
Crossref (1)
Scopus Crossref
Publication Date
Mon Mar 31 2014
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Evaluation of Sodium Chloride and Acidity Effect on Corrosion of Buried Carbon Steel Pipeline in Iraqi Soil
...Show More Authors

In this work, corrosion parameters were evaluated using potentiodynamic polarization curves. In order to determine corrosion parameters of potential and current density of the interesting metal, carbon steel, environmental conditions of external corrosion of buried carbon steel pipeline in Iraqi soil were prepared in the laboratory using simulated prepared conditions. Solutions of sodium chloride at different concentrations (300, 1100, 1900, 2700, and 3500 ppm) were used. pH of solution were acidic at pH =5, and alkaline at pH = 9. Laboratory conditions were similar to those of Iraqi soil where the pipelines were buried. Temperature was constant at 20 °C. Potentiodynamic polarization curves, of potential vs. log current density, were ob

... Show More
View Publication Preview PDF
Publication Date
Thu Jan 30 2025
Journal Name
Iraqi Journal Of Science
Development of A New Colorimetric-Flow System Approach for The Determination of Cefotaxime Sodium in Pharmaceutical Formulations
...Show More Authors

     A new colorimetric-flow injection method has been developed and validated for the detection of Cefotaxime sodium in pharmaceutical formulations. This method stands out for its rapid and sensitive nature. The formation of a brown-colored complex between Cefotaxime sodium and the Biuret reagent in a highly alkaline environment serves as the basis for the detection. The intensity of this colored complex is measured using a custom-built Continuous Flow Injection Analyzer, enabling accurate quantification of Cefotaxime sodium. Optimization studies of the chemical and physical parameters such as dilution of Biuret reagent, effect of the medium basicity, flow rate, sample loop and others have been investigated. The calibration gra

... Show More
View Publication
Scopus (1)
Scopus Crossref
Publication Date
Tue Jan 01 2019
Journal Name
Technologies And Materials For Renewable Energy, Environment And Sustainability: Tmrees19gr
Theoretical calculations involving a standard neutron yield distribution for the T-T nuclear fusion reaction
...Show More Authors

A standard theoretical neutron energy flux distribution is achieved for the triton-triton nuclear fusion reaction in the range of triton energy about ≤10 MeV. This distribution give raises an evidence to provide the global calculations including the characteristics fusion parameters governing the T-T fusion reaction.

View Publication Preview PDF
Scopus Clarivate Crossref
Publication Date
Tue Oct 30 2018
Journal Name
Journal Of Engineering
Direct Contact Membrane Distillation for Desalination Brine Solution
...Show More Authors

Desalination is a process where fresh water produces from high salinity solutions, many ways used for this purpose and one of the most important processes is membrane distillation (MD). Direct contact membrane distillation (DCMD) can be considered as the most prominent type from MD types according to ease of design and modus operandi. This work studies the efficiency of using DCMD operation for desalination brine with different concentration (1.75, 3.5, 5 wt. % NaCl). Frame and plate cell was used with flat sheet PTFE hydrophobic type membrane. The study proves that MD is an effective process for desalination brines with feed temperature less than 60˚C especially for feed with low TDS. 37˚C, 47˚C, and 57˚C was feed t

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Sep 01 2020
Journal Name
Baghdad Science Journal
Oxidative Coupling Reaction for Micro Trace Analysis of Mebendazol Residual with p-bromoaniline in Presence of n- bromosuccinimide
...Show More Authors

Rapid, reproducible and accurate method has been developed for the assay for of mebendazol (MBZ) residual assay. The method is based on alkaline hydrolysis of MBZ with sodium hydroxide then oxidation with N-bromosuccinimide (NBS) followed by coupling with 4-Bromoaniline (4-BA) to yield a highly colored product absorbed at maximum 434 nm. Regression analysis of linearity range was found (0.6-2.8) µg.ml-1.  The optimum conditions that affect the oxidation were studied. The developed method was found to be precise with mean value of relative standard deviation (1.153- 1.303) and accurate with relative error (-0.5940-1.7821) .The calculated molar absorptivity and sandal sensitivity values of (29825 L.mol-1.cm

... Show More
View Publication Preview PDF
Scopus (4)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Fri Jun 01 2018
Journal Name
Kerbala Journal Of Medicine
Polymerase Chain Reaction Testing in Comparison to Culture of Cerebrospinal Fluid for Diagnosis of Bacterial Meningitis in Children
...Show More Authors

View Publication