Preferred Language
Articles
/
ijcpe-225
Kinetic of Disinfection reaction by Sodium Hypochlorite Solution
...Show More Authors

The present studier aims to study the kinetic of reaction at different experimental conditions depending on coliform bacteria concentration and hypochlorite ion. The effects that had been investigated were different of sodium hypochlorite doses, contact time, pH and temperature (20, 29, 37) o C. The water samples were taken from Al-Wathba water treatment plant in Risafa side of Tigris River in Baghdad. The biological tests included the most probable number (M.P.N) for indicating the concentration of coliform bacteria with different contact times and the total plate count (T.P.C) for indicating the amount of colonies for general bacteria. The iodimetry method (chemical test) was used for indicating the concentration of hypochlorite ion with different contact times. Different models were examined to fit the experimental data including the kinetics power law (first and second order) and Selleck model. It was found that the Selleck model fitted well the experimental data in which degree of Selleck model was equal to two and the rate constants was 1.3791 x 10-5 L / (mole min) at 20o C, 3.0806 x 10-5 L / (mole min) at 29oC, and 5.738 x 10-5 L / (mole min) at 37o C.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Dec 31 2000
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Performance of the Fluidized-Beds Adsorbers
...Show More Authors

View Publication Preview PDF
Publication Date
Mon Mar 23 2020
Journal Name
Journal Of Engineering
Survey Study of Factional Order Controllers
...Show More Authors

This is a survey study that presents recent researches concerning factional controllers. It presents several types of fractional order controllers, which are extensions to their integer order counterparts. The fractional order PID controller has a dominant importance, so thirty-one paper are presented for this controller. The remaining types of controllers are presented according to the number of papers that handle them; they are fractional order sliding mode controller (nine papers), fuzzy fractional order sliding mode controller (five papers), fractional order lag-lead compensator (three papers), fractional order state feedback controller (three papers), fractional order fuzzy logic controller (three papers). Finally,

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Jul 01 2021
Journal Name
Iraqi Journal Of Science
Synthesis and Characterization of Cu2FeSnSe4 Nanofilms
...Show More Authors

Well dispersed Cu2FeSnSe4 (CFTSe) nanofilms were synthesized by hot-injection method. The structural and morphological measurements were characterized using XRD (X-ray diffraction), Raman spectroscopy, SEM (scanning electron microscopy), and TEM (transmission electron microscopy). Chemical composition and optical properties of as-synthesized CFTSe nanoparticles were characterized using EDS (energy dispersive spectroscopy) and UV-Vis spectrophotometry. The average particle size of the nanoparticles was about 7-10 nm. The UV-Vis absorption spectra showed that the synthesized CFTS nanofilms have a band gap (Eg) of about 1.16 eV. Photo-electrochemical characteristics of CFTSe nanoparticles were studied and in

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Sun Oct 03 2010
Journal Name
Journal Of The Faculty Of Medicine Baghdad
Anatomical Study of Axillary Artery Variation.
...Show More Authors

Background: The axillary artery is a direct continuation of the subclavian artery. The axillary artery is usually described as giving off six branches. The first part gives superior thoracic artery. The second part gives lateral thoracic (LT) and thoracoacromial(TAC) arteries. The third part gives three, subscapular(SS), anterior circumflex humeral(ACH)and posterior circumflex humeral(PCH) arteries. Anatomical variations in the branching pattern of axillary artery are quiet common and typically include the subscapular artery(SS), lateral thoracic artery(LT) and the posterior circumflex humeral artery(PCH). The variation of the axillary artery branching pattern has anatomical as well as clinical and surgical

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Mar 30 2003
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Performance of Countercurrent Flow Cooling Towers
...Show More Authors

View Publication Preview PDF
Publication Date
Fri Jan 10 2025
Journal Name
Al–bahith Al–a'alami
Translating Acronyms of Media & U.N. Organizations
...Show More Authors

: translating acronyms of media and international (& world) organizations helps the researcher to draw the following conclusions:1- Acronyms of world news agencies can be translated into Arabic in three ways: by indicating the lexical meaning; by indicating English abbreviated form as letter by letter & by indicating Arabic abbreviated form as a word. 2- Acronyms of world satellite TV's can be translated into Arabic in two ways: by indicating the lexical meaning & by indicating English abbreviated form as letter by letter. 3- Acronyms of world newspapers can be translated into Arabic in two ways: by indicating both the lexical meaning & Arabic transliteration of the English form. 4- Acronyms of U.N. & world organizati

... Show More
View Publication Preview PDF
Publication Date
Tue Sep 30 2008
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Electrocoagulation of phenol for wastewater treatment
...Show More Authors

Electrocoagulation is an electrochemical process of treating polluted water where sacrificial anode corrodes to produce active coagulant (usually aluminum or iron cations) into solution. Accompanying electrolytic reactions evolve gas (usually as hydrogen bubbles). The present study investigates the removal of phenol from water by this method. A glass tank with 1 liter volume and two electrodes were used to perform the experiments. The electrode connected to a D.C. power supply. The effect of various factors on the removal of phenol (initial phenol concentration, electrode size, electrodes gab, current density, pH and treatment time) were studied. The results indicated that the removal efficiency decreased as initial phenol concentration

... Show More
View Publication Preview PDF
Publication Date
Sun Feb 10 2019
Journal Name
Journal Of The College Of Education For Women
Enhance Similarity Measure of Ontologys' Concepts
...Show More Authors

The field of identification of similarity was considered a subject of research strongly recommended in the areas of semantic web, artificial intelligence and linguistic literature. In this paper a new similarity measure is proposed based on the Wu and Palmer measure. This measure is applied on the domain of the pedagogical ontology. Results obtained showed that the new measure gives better relevance of the similarity values compared to the approach of Wu and Palmer and it appears that the proposed measure is advantageous because obtained results showed that it is faster and capable of obtaining results to concepts not located in the same path.

View Publication
Publication Date
Sun Mar 07 2010
Journal Name
Baghdad Science Journal
Selection of highly ethanol productive yeast
...Show More Authors

Seventy five isolates of Saccharomyces cerevisiae were identified, they were isolated from different local sources which included decayed fruits and vegetables, vinegar, fermented pasta, baker yeast and an alcohol factory. Identification of isolates was carried out by cultural microscopical and biochemical tests. Ethanol sensitivity of the isolates showed that the minimal inhibitory concentration of the isolate (Sy18) was 16% and Lethal concentration was 17%. The isolate (Sy18) was most efficient as ethanol producer 9.36% (v/w). The ideal conditions to produce ethanol from Date syrup by yeast isolate, were evaluated, various temperatures, pH, Brix, incubation period and different levels of (NH4)2HP04. Maximum ethanol produced was 10

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Mar 02 2008
Journal Name
Baghdad Science Journal
Design and construction of Video extractor
...Show More Authors

Design and construction of video extractor circuit require an understanding of several parameters, which include: Selector circuit, extracting circuit which contains sampling signal and multiplexing. At each radar pulse, the video signal is fed to one of the selector. The fast filter has a pass –band from 190 Hz to 1800 Hz. These frequencies correspond to targets having radial velocities laying between and 10 Kph and 200 Kph.Slow filter: 60 Hz to 230 Hz for radial velocities laying between 3.5 and 13 Kph.The video- extractor is organized in four PCB CG (A-B-C-D) each one having 16 selector. The sampling signal (ADS) (1-2-3-4) control the 4-line-to-16-line decoders. 8 multiplexers of 8 inputs each, are required for the multiplexing of the

... Show More
View Publication Preview PDF
Crossref