The adsorption isotherms and kinetic uptakes of CO2 were measured. Adsorption isotherms were measured at two temperatures 309 K and 333 K and over a pressure range of 1 to 7 bar. Experimental data of CO2 adsorption isotherms were modeled using Langmuir, Freundlich and Temkin. Based on coefficient of correlation it was found that Langmuir isotherm model was well suited with the experimental data of CO2 adsorption isotherms. In addition, Adsorption kinetic of CO2 mixture with N2 containing 10 % by volume CO2 and 90 % by volume N2 were determined in a temperature 36 °C and under the atmospheric pressure .When the flow rate was increased from 0.5 l/min to 2 l/min the time required for complete column saturation decreased. Also the effect of bed length on breakthrough curves was studied. The adsorption capacity increases by bed length increasing for adsorption of carbon dioxide.
The research aims to determine the role of training strategy dimensions of (trainers، curriculum training programs، trainees and their desire for training، administrative and supervisory services and their impact on the success of the training program) in the entrepreneurial performance of the organization dimensions of (pre-planning، renovation and modernization، efficiency، effectiveness)، so search ranks of great importance because it addresses an important and modern issue in performance entrepreneurial، and strategy training، aware of the importance of the subject and expected outcomes (General company for electrical Industries - motor plant) surveyed، was an analysis of data obtained through field visits in addition to the q
... Show MoreThe research aims to determine the role of knowledge management to measure performance on a sample of faculties of Administration and Economics the University of Kufa, and to achieve this goal through a researcher from the theoretical literature and research and studies related to the construction of the scheme shows the hypothetical relationship between the variables, which was adopted by the independent variable knowledge management, distributed four variables are: (knowledge generation, knowledge storage, knowledge dissemination, the application of knowledge), as well as four variables representing the variables adopted for the performance of the university are:
(to reduce costs and increase profits, improve quality, scie
Removing hazardous organic pollutants, such as 4-nitrophenol (4-NP) and Congo red (CR) dyes from aqueous media and CO2 from the atmospheric medium remains a significant challenge. Herein, we report a facile in-situ synthetic approach for fabricating CuO-ZnO heterostructure photocatalysts through the surfactant-assisted co-precipitation method. The catalytic results demonstrate that the Cu1O-ZnO photocatalyst exhibits excellent activity under direct sunlight irradiation, owing to the heterostructure formation between the CuO and ZnO. The Cu1O-ZnO photocatalyst showed higher reaction rate constant (k) values of 0.20 min−1 for 4-NP and 0.09 min−1 for CR compared to previous reports. Additionally, efficient CO2 reduction was also achiev
... Show MoreThe present work investigates the effect of; superficial air velocities of: 1, 3, and 6 cm/s for two types of perforated distributor on hydrodynamic characteristic in a gas-liquid dispersion column of; air-water, and airaqueous-n-propanol solution. Bubble distribution, gas holdup, and power consumption are parameters take in consideration. Experimental work was carried out in perspex column of 8.5 cm inside diameter and 1.5 m height. Two types of bubble generator (perforated plate) were fixed at the bottom of the column; plate A (99 holes of 0.5 mm diameter and free area of 0.34%), plate B (20 holes of 1.5 mm diameter and free area of 0.62%). Photographic technique was used to measure the bubble parameters. The experimental results were
... Show MoreCopper Telluride Thin films of thickness 700nm and 900nm, prepared thin films using thermal evaporation on cleaned Si substrates kept at 300K under the vacuum about (4x10-5 ) mbar. The XRD analysis and (AFM) measurements use to study structure properties. The sensitivity (S) of the fabricated sensors to NO2 and H2 was measured at room temperature. The experimental relationship between S and thickness of the sensitive film was investigated, and higher S values were recorded for thicker sensors. Results showed that the best sensitivity was attributed to the Cu2Te film of 900 nm thickness at the H2 gas.