Preferred Language
Articles
/
ijcpe-1112
Flotation of Chromium Ions from Simulated Wastewater Using Air Microbubbles
...Show More Authors

   A microbubble air flotation technique was used to remove chromium ions from simulated wastewater (e.g. water used for electroplating, textiles, paints and pigments, and tanning leather). Experimental parameters were investigated to analyze the flotation process and determine the removal efficiency. These parameters included the location of the sampling port from the bottom of the column, where the diffuser is located to the top of flotation column (30, 60, and 90 cm), the type of surfactant (anionic, SDS, or cationic, CTAB) and its concentration (5, 10, 15, and 20 mg/L), the pH of the initial solution (3, 5, 7, 9, and 11), the initial contaminant concentration (10, 20, 30, and 40 mg/L), the gas flow rate (0.1, 0.2, 0.3, and 0.5 L/min), and the contact time (5, 10, 15, 20, 25, 30, and 35 min). The experimental results revealed that the highest removal efficiency (95%) was achieved in 20 min with a pH of 7, a flow rate of air 0.5 L/min, an SDS surfactant concentration of 15 mg/L, and a pollutant concentration of 30 mg/L at a sampling port height of 30 cm. The use of microbubbles in comparison to normal bubbles, resulted in a 56% improvement of the removal efficiency. The flotation process follows a first-order kinetics.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Jan 01 2020
Journal Name
Studies In Big Data
COVID-19 Diagnostics from the Chest X-Ray Image Using Corner-Based Weber Local Descriptor
...Show More Authors

Corona Virus Disease-2019 (COVID-19) is a novel virus belongs to the corona virus's family. It spreads very quickly and causes many deaths around the world. The early diagnosis of the disease can help in providing the proper therapy and saving the humans' life. However, it founded that the diagnosis of chest radiography can give an indicator of coronavirus. Thus, a Corner-based Weber Local Descriptor (CWLD) for COVID-19 diagnostics based on chest X-Ray image analysis is presented in this article. The histogram of Weber differential excitation and gradient orientation of the local regions surrounding points of interest are proposed to represent the patterns of the chest X-Ray image. Support Vector Machine (SVM) and Deep Belief Network (DBN)

... Show More
View Publication
Scopus (3)
Crossref (2)
Scopus Crossref
Publication Date
Tue Jun 30 2009
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Phosphorus Removal from Water and Waste Water by Chemical Precipitation Using Alum and Calcium Chloride
...Show More Authors

Phosphorus is usually the limiting nutrient for eutrophication in inland receiving waters; therefore, phosphorus concentrations must be controlled. In the present study, a series of jar test was conducted to evaluate the optimum pH, dosage and performance parameters for coagulants alum and calcium chloride. Phosphorus removal by alum was found to be highly pH dependent with an optimum pH of 5.7-6. At this pH an alum dosage of 80 mg/l removed 83 % of the total phosphorus. Better removal was achieved when the solution was buffered at pH = 6. Phosphorus removal was not affected by varying the slow mixing period; this is due to the fact that the reaction is relatively fast.
The dosage of calcium chloride and pH of solution play an importa

... Show More
View Publication Preview PDF
Publication Date
Mon Sep 01 2014
Journal Name
Paripex-indian Journal Of Research
Inundation Map Development by Using HEC-RAS Hydraulic Simulation Modeling from Roseires to Khartoum Cities
...Show More Authors

Inundation floodingmap aimedto find outearly warningsto avoidenvironmental damageandhumanin terms of theheight ofthe wave ofwater, speed time arrival, effects of inundation sideanddepth of the water/ distanceand reduce the impact of the flood wave after obtaining the process of collapse of the dam in the lower part of the river to the dam area. The study has been using a numerical model one-dimensional depends on the development of equations (Saint-Venant) so that parts of the river, any river channel main banks of the right and left treated as separate parts, that’s the difference in the characteristics of the hydraulic and engineering, along the line of the flow will take into account in each section of the sections and flow in the riv

... Show More
Publication Date
Thu Jul 03 2025
Journal Name
2025 3rd International Conference On Cyber Resilience (iccr)
Fine-Grained Emotion Recognition from Short Video Clips Using CNN-LSTM with Facial Action Heatmaps
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Tue Sep 30 2025
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Tetracycline removal from aqueous solution through photo-anodic oxidation process using rotating graphite cylinder anode
...Show More Authors

   In the present work, tetracycline (TC) was removed from a simulated wastewater through a new photo-anodic oxidation process with a rotating graphite cylinder anode. The effects of current density, pH, rotation speed, and NaCl addition were evaluated. The results confirmed that increasing the current density results in improving the removal of TC. However, increasing the current density beyond 5 mA/cm2 had little effect on TC removal. Results revealed that TC removal using photoanodic oxidation can be achieved at high performance with an initial pH of 5. Increasing or decreasing pH beyond this value has a negative effect on TC removal. Increasing rotation speed gave better performance for TC removal due to the increase in mass t

... Show More
View Publication
Crossref (1)
Crossref
Publication Date
Wed Sep 01 2021
Journal Name
Iranian Endodontic Journal
Smear Layer Removal from the Apical Third Using the Er,Cr:YSGG Photon-induced Photoacoustic Streaming
...Show More Authors

Scopus (15)
Scopus
Publication Date
Wed Jun 01 2022
Journal Name
Baghdad Science Journal
Kinetic, Isotherm and Thermodynamic Studies on the Ciprofloxacin Adsorption from Aqueous Solution Using Aleppo bentonite
...Show More Authors

          Aleppo bentonite was investigated to remove ciprofloxacin hydrochloride from aqueous solution. Batch adsorption experiments were conducted to study the several factors affecting the removal process, including contact time, pH of solution, bentonite dosage, ion strength, and temperature. The optimum contact time, pH of solution and bentonite dosage were determined to be 60 minutes, 6 and 0.15 g/50 ml, respectively. The bentonite efficiency in removing CIP decreased from 89.9% to 53.21% with increasing Ionic strength from 0 to 500mM, and it increased from 89% to 96.9% when the temperature increased from 298 to 318 K. Kinetic studies showed that the pseudo second-order model was the best in describing  the adsorption sys

... Show More
View Publication Preview PDF
Scopus (12)
Crossref (8)
Scopus Clarivate Crossref
Publication Date
Tue Jul 30 2024
Journal Name
Iraqi Journal Of Science
Frame-Based Change Detection Using Histogram and Threshold to Separate Moving Objects from Dynamic Background
...Show More Authors

      Detecting and subtracting the Motion objects from backgrounds is one of the most important areas. The development of cameras and their widespread use in most areas of security, surveillance, and others made face this problem. The difficulty of this area is unstable in the classification of the pixels (foreground or background). This paper proposed a suggested background subtraction algorithm based on the histogram. The classification threshold is adaptively calculated according to many tests. The performance of the proposed algorithms was compared with state-of-the-art methods in complex dynamic scenes.

View Publication Preview PDF
Scopus (1)
Scopus Crossref
Publication Date
Fri Jan 01 2021
Journal Name
Ieee Access
Keratoconus Severity Detection From Elevation, Topography and Pachymetry Raw Data Using a Machine Learning Approach
...Show More Authors

View Publication
Scopus (25)
Crossref (23)
Scopus Clarivate Crossref
Publication Date
Wed Dec 10 2014
Journal Name
Desalination And Water Treatment
Groundwater protection from lead contamination using granular dead anaerobic sludge biosorbent as permeable reactive barrier
...Show More Authors

Scopus (29)
Crossref (25)
Scopus Clarivate Crossref