Preferred Language
Articles
/
ihbWrosBVTCNdQwCCNbr
KNOWLEDGE AND MALPRACTICES IN PEDIATRICS DIARRHEA MANAGEMENT BY IRAQI MOTHERS
...Show More Authors

Objectives: In developing countries like Iraq, diarrhea was responsible for 70% of deaths among pediatrics. This study was designed to determine Iraqi mothers’ knowledge and malpractices associated with diarrhea management in pediatrics.Methods: A cross-sectional pilot study was done on a convenient sample of mothers in Baghdad – Iraq. Data collection was done using a validated questionnaire specifically designed for this study.Result: Most participants preferred to consult physicians or pharmacists about pediatrics diarrhea management. Breastfeeding was stopped by 19% of participants, whereas 35% of mothers who depend on formulated milk discontinued it. Only 30% of participants use oral rehydration solution therapy always as a part of treatment. Although 54% of participated mothers certainly not used antibiotics for the diarrhea management before doctor consultation, however 52.5% of these mothers used antimotility suspensions without any consultation. 17% of participants used some herbal preparations in addition to 11% used some forms of traditional harmful preparations (Al-Sagwa) to manage diarrhea.Conclusions: This study indicates a good level of knowledge about diarrhea management for most participants, although there are some wrong concepts which followed by a small percentage of mothers, especially the most dangerous malpractices of using Al-Sagwa.

Scopus Crossref
View Publication
Publication Date
Tue Jan 01 2019
Journal Name
Association Of Arab Universities Journal Of Engineering Sciences
Experimental and numerical investigation on the behavior of reinforced reactive powder concrete two-way slabs under static load
...Show More Authors

This paper studied the behaviour of reinforced reactive powder concrete (RPC) two-way slabs under static load. The experimental program included testing three simply supported slabs of 1000 mm length, 1000 mm width, and 70 mm thickness. Tested specimens were of identical properties except their steel fibers volume ratio (0.5 %, 1 %, and 1.5 %). Static test results revealed that, increasing steel fibers volume ratio from 0.5% to 1% and from 1% to 1.5%, led to an increase in: first crack load by (32.2 % and 52.3 %), ultimate load by (36.1 % and 17.0 %), ultimate deflection by (33.6 % and 3.4 %), absorbed energy by (128 % and 20.2 %), and the ultimate strain by (1.1 % and 6.73 %). The stiffness and ductility of the specimens also increased. A

... Show More
View Publication
Publication Date
Thu May 31 2012
Journal Name
Al-khwarizmi Engineering Journal
An Experimental Study on the Effect of Shape and Location of Vortex Generators Ahead of a Heat Exchanger
...Show More Authors

An experimental study is carried out on the effect of vortex generators (Circular and square) on the flow and heat transfer at variable locations at (X = 0.5, 1.5, 2.5 cm) ahead of a heat exchanger with Reynolds number ranging from 62000< Re < 125000 and heat flux from 3000 ≤ q ≤ 8000 W/m2 .

In the experimental investigation, an apparatus is set up to measure the velocity and temperatures around the heat exchanger.                     

The results show that there is an effect for using vortex generators on heat transfer. Also, heat transfer depends on the shape and location. The circular is found t

... Show More
View Publication Preview PDF
Publication Date
Mon Nov 27 2023
Journal Name
Future Oncology
Plain Language Review: What are Biosimilar Medicines and how Can they be Used to Treat People with Cancer?
...Show More Authors

View Publication
Scopus (2)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Sun Mar 01 2020
Journal Name
Journal Of Engineering
The effect of titanium oxide microparticles on mechanical properties, absorption and solubility processes of a glass ionomer cement
...Show More Authors

Glass Ionomer Cement (GIC) is one of the important dental temporary filing materials. The aim of this study is to evaluate the effect of adding 3, 5 and 7 wt. % of TiO2 microparticles to conventional GIC powder (Riva Self Cure) on mechanical properties and its effect on absorption and solubility processes. TiO2 particles additives improved compressive strength and biaxial flexural strength, where the compressive strength increased with increasing in the added ratio, while the highest value of the biaxial flexural strength was at 3 wt.%. The addition of TiO2 particles improved the surface Vickers microhardness values, with highest value at 5 wt. %. On other hand TiO2 addition im

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Fri Jun 30 2023
Journal Name
Studia Universitatis Babeș-bolyai Chemia
Antitumor and antioxidant potential of majorana hortensis extract binding to the silver nanoparticles on lungs cancer cell line
...Show More Authors

View Publication Preview PDF
Scopus (2)
Scopus Clarivate Crossref
Publication Date
Wed May 12 2021
Journal Name
Indian Journal Of Forensic Medicine &amp; Toxicology
The Relationship of Healthy Rationalist Pundit Thinking to the Spiking and Block Performance of Volleyball For Junior Players
...Show More Authors

View Publication
Crossref
Publication Date
Fri Apr 14 2017
Journal Name
Mechanical Engineering
Testing a Locally Assembled Combine Implement Used for Open Furrow, Planting and Fertilizing under Different Machinery Unit Speeds
...Show More Authors

Preview PDF
Publication Date
Thu Jun 20 2024
Journal Name
Frontiers In Microbiology
Removal of mobile genetic elements from the genome of Clostridioides difficile and the implications for the organism’s biology
...Show More Authors

Clostridioides difficile is an emerging pathogen of One Health significance. Its highly variable genome contains mobile genetic elements (MGEs) such as transposons and prophages that influence its biology. Systematic deletion of each genetic element is required to determine their precise role in C. difficile biology and contribution to the wider mobilome. Here, Tn5397 (21 kb) and ϕ027 (56 kb) were deleted from C. difficile 630 and R20291, respectively, using allele replacement facilitated by CRISPR-Cas9. The 630 Tn5397 deletant transferred PaLoc at the same frequency (1 × 10−7

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Wed Feb 10 2021
Journal Name
Materials Today: Proceedings
Characterizations and testing some mechanical properties of prepared PMMA-Lithium disilicate glass ceramic composite for denture base application
...Show More Authors

Denture bases are fabricated routinely using Poly(methyl methacrylate) (PMMA) acrylic resin. Yet, it is commonly known for its major drawbacks such as insufficient strength and ductility. The purpose of this study was to improve the performance of PMMA acrylic resin as a denture base material by reinforcement with surface treated lithium disilicate glass ceramic powder. The ceramic powder was prepared by grinding and sieving IPS e.max CAD MT blocks. Then, the powder was surface treated with an organosilane coupling agent (TMSPM) and added to PMMA in amount of 1%, 3%, 5% and 7% by weight. Characterizations of the powder was done by particle size analysis, XRD and FTIR. Transverse strength, Impact strength, Shore D hardness and surface roughn

... Show More
View Publication
Scopus (2)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Wed Aug 29 2018
Journal Name
Biomedical And Pharmacology Journal
Comparison of Some Mechanical and Physical Properties of three Types of Impression Materials with Different Dental Implant Angulations
...Show More Authors

Choosing an appropriate impression material is a challenge for many dentists, yet an essential component to provide an excellent clinical outcome and improve productivity and profit. The purpose of present study was to compare wettability, tear strength and dimensional accuracy of three elastomeric impression materials, with the same consistencies (light-body). Three commercially available light body consistency and regular set 3M ESPE Express polyvinylsiloxane (PVS), 3M ESPE Permadyne polyether (PE), and Identium (ID), impression materials were comparedTear strength test, contact angle test and linear dimensional accuracy were evaluated for three elastic impression material. Among the three experimental groups PE impression materia

... Show More
View Publication
Crossref (2)
Crossref