Thermal effectiveness of solar collector using Graphene nanostructures suspended in ethylene glycol–water mixtures
...Show More Authors
The goal of this research to identify a set of criteria that can be measured on the basis of which the effectiveness of the application of the Balanced Scorecard in the Jordanian Public Institutions in order to identify the basic requirements to ensure the application of balanced performance measures. The study population consisted of the staff of the Public Institution for Social Security - Irbid of directors of departments and heads of departments and administrative staff, was the use of a random sample of (50) an employee and the employee. The questionnaire was used as a tool to collect data, and as a result of subjecting these standards for the field test and the use of statistical analysis tools to the results of the study c
... Show MoreAbstract in English The aim of this study is to identify the effectiveness of rehabilitation exercises in conjunction with aquatic therapy for those suffering from sacroiliitis in football players. The researcher used the experimental approach, using the experimental design (pre-measurement, post-measurement). Similar to the objectives and procedures of the research, the researcher assumed the following: the existence of significant differences. Statistics between pre- and post-measurements in variables in favor of post-measurement for the following variables (degree of pain and level of balance). The experimental approach was used with a pre- and post-measurement design on one group of football players with sacroiliitis, nu
... Show MoreThe corrosion behavior of low carbon steel in washing water of crude oil solution has been studied potentiostatically at five temperatures in the range (30–70)°C .The corrosion potential shifted to more negative values with increasing temperature and the corrosion current density increased with increasing temperature. Folic acid had on inhibiting effect on the corrosion of low carbon steel in washing water at a concentration (5× 10-4-- 5× 10-3 ) mol/dm3 over the temperature range (30–70)°C. Values of the protection efficiency were calculated from the corrosion current density .From the general results for this study, it can be seen that thermodynamic and kinetic function were also calculated (?G, ?S, ?H and Ea )
... Show MoreThis research studies the influence of water source on the compressive strength of high strength concrete. Four types of water source were adopted in both mixing and curing process these are river, tap, well and drainage water (all from Iraq-Diyala governorate). Chemical analysis was carried out for all types of the used water including (pH, total dissolved solids (TDS), Turbidity, chloride, total suspended solid (TSS), and sulfates). Depending on the chemical analysis results, it was found that for all adopted sources the chemical compositions was within the ASTM C 1602/C 1602M-04 limits and can be satisfactorily used in concrete mixtures. Mixture of high strength concrete for compressive strength of (60 MPa) was designed and checked using
... Show MoreGranular carbon can be used after conventional filtration of suspended matter or, as a combination of filtration - adsorption medium. The choice of equipment depends on the severity of the organic removal problem, the availability of existing equipment, and the desired improvement of adsorption condition.
Design calculations on dechlorination by granular - carbon filters considering the effects of flow rate, pH , contact time, head loss and bed expansion in backwashing , particle size, and physical characteristics were considered assuming the absence of bacteria or any organic interface .
This study is conducted in order to, investigate the trophic state of Duhok Lake Dam located within Duhok city, Iraq. Water samples are collected seasonally from three monitored sites during 2011. The parameters used for assessing water quality and trophic status level include: water temperature, pH, EC, TDS, DO, BOD5, nutrients, Secchi disk transparency, and chlorophyll a. The results reveal that DO is above 5 mg.l-1 in all sites, BOD5 value is within permissible level for domestic uses. Water quality considered as a hard type. High sulfate concentration is recorded during the study period. Trophic state shows that water type is classified as mesotrophic during autumn season, while it is regarded as eutrophic in other seasons. TDN/TDP rati
... Show More