Lower limb Rehabilitation Robots (LLRRs) assist in therapeutic tasks that involve gait recovery and joint mobility recovery of the lower limbs, in patients recovering from neurologic injuries such as stroke as well as spinal cord injury. LLRRs can sometimes be driven by preprogrammed trajectories or Inverse Kinematics (IK) trajectories, which bring increased computational demand and command supported interaction. This paper proposes an interactive control framework for LLRRs using a hybrid mix of Forward Kinematics (FK) driven movement and an offline Voice Conversational Agent (VCA), based on the Vosk speech recognition engine. The framework proposed is modular in nature that is completely “local”, running offline with no need for the Internet, preserving privacy, and not needing to send uploads cards to cloud processing units. Spoken commands, such as “forward”, “backward”, “rest”, “exercise”, and “stop” are mapped to hip and knee joint angles, which are then driven to FK equations for deriving leg segment positions in an ongoing manner. A hybrid MATLAB-Python implementation is used, where MATLAB is used for simulation and animation, while Python captures the audio input and runs the offline speech recognition component. Recognized transcripts are resolved through fuzzy command matching and are followed by a confidence gated execution to improve tolerance to Automatic Speech Recognition (ASR) variability. Under controlled conditions, command recognition accuracy ranging from 80% to 95%, with end-to-end latencies ranging from 0.89 to 1.32 sec. were seen for the evaluated commands. The performance of feasible offline voice guided interaction and reasonably smooth, anatomically consistent motion transitions, as shown in simulation, provide evidence for the working of the proposed architecture. The main contribution of the work lies in the explicit exposure of ASR offline, fuzzy command matching, applying confidence gated execution, and the use of FK based motion generation, all within a lightweight LLRR oriented framework. This should be enough substrate for future hardware validation, and phase synchronized wearables deployment.
This study aims to assess the water quality index (WQI) according to the Canadian Council of Ministers of the Environment's Water Quality Index method (CCME WQI). Four locations (measurement stations) are selected along the Tigris River, in Iraq. Two of them are located in the north near Mosul City, (Mosul Dam and Mosul city), and the other two are located in the south near Al-Amarah city, (Ali Garbi and Al-Amarah). The water data collected is for the period 2011 to 2013, including eleven water quality parameters. These are magnesium (Mg+2), calcium (Ca2+), potassium (K+), sodium (Na+), sulfate (SO42-), chloride (Cl-), nitrate (NO3<
... Show MoreThis study focused on treatment of real wastewater rejected from leather industry in Al-Nahrawan city in Iraq by Electrocoagulation (EC) process followed by Reverse Osmosis (RO) process. The successive treatment was applied due to high concentration of Cr3+ ions (about 1600 ppm) rejected in wastewater of this industry and for applying EC with moderate power consumption and better results of produced water. In Electrocoagulation process (EC), the effect of NaCl concentration (1.5, 3 g/l), current density (C.D.) (15-25 mA/cm2), electrolysis time (1-2 h), and distance between electrodes (E.D.) (1-2 cm) were examined in a batch cell by implementing Taguchi experimental design. According to the results obtained from multiple regression and signa
... Show MoreAn easy, eclectic, precise high-Performance Liquid Chromatographic (HPLC) procedure was evolved and validated to estimate of Piroxicam and Codeine phosphate. Chromatographic demarcation was accomplished on a C18 column [Use BDS Hypersil C18, 5μ, 150 x 4.6 mm] using a mobile phase of methanol: phosphate buffer (60:40, v/v, pH=2.3), the flow rate was 1.1 mL/min, UV detection was at 214 nm. System Suitability tests (SSTs) are typically performed to assess the suitability and effectiveness of the entire chromatography system. The retention time for Piroxicam was found to be 3.95 minutes and 1.46 minutes for Codeine phosphate. The evolved method has been validated through precision, limit of quantitation, specificity,
... Show MoreHepatocellular carcinoma (HCC) is the third most common cause of cancer-related death. Therefore, it is critical for researchers to understand molecular biology in greater depth. In several diseases including cancer, abnormal miRNA expression has been linked to apoptosis, proliferation, differentiation, and metastasis. Many miRNAs have been studied in relation to cancer, including miR-122, miR-223, and others. Hepatitis B and C viruses are the most important global risk factors for HCC. This study is intended to test whether serum miRNAs serve as a potential biomarker for both HCC and viral infections HBV and C. The expression of miRNA in 64 serum samples was analyzed by RT-qPCR. Compared to healthy volunteers, HCC patients' sera expre
... Show MoreBackground: Diagnosis and treatment planning can be difficult with conventional radiographic methods as the orthodontic-surgical management of impacted canines requires accurate diagnosis and precise localization of the impacted canine and the surrounding structures. This study was aimed to localize and evaluate weather there is any differences in the diagnostic information provided by multi-slice computed tomography three dimensional volumetric CT images and two dimensional reconstructed panorama images (derived from CT) in subjects with impacted maxillary canines. Materials and Methods: Thirty patients including 24 female and 6 male with mean age of 18 years with suspected unilaterally or bilaterally impacted maxillary canines were evalu
... Show More