This research was conducted to measure the safety of heat stable enterotoxin a (STa) produced by enterotoxigenic Escherichia coli, through studying its toxic effect on human blood lymphocyte, since it showed a promising effect in reducing the proliferation of colorectal cancer cells. the cytogenetic effects of (STa) by using five different concentrations (100, 200, 400, 800 and 1600μg/ml) in comparison with negative (PBS, Phosphate buffer saline) and positive (MMC, Mitomycin C) at concentration of 5μg/ml, controls on human blood lymphocytes obtained from both (10) normal healthy persons and (20) colorectal cancer patients was measured by employing the following parameters: mitotic index, blast index, chromosomal aberrations and micronucleus. On the human blood lymphocytes obtained from normal healthy persons, results showed that STa, and within all the different used concentrations, did not cause any significant cytogenetic changes in the all studied cytogenetic parameters. While on the human blood lymphocytes obtained from patients with colorectal cancer, STa was shown to cause significant decrease in both mitotic and blast index, and especially at both concentrations of (800 and 1600μg/ml) and this decrease was concentration dependent, but at the same time non significant changes were seen in both chromosomal aberrations and micronucleus parameters and for the all used concentrations. However, reduced mitotic and blast index and induced chromosomal aberrations and micronucleus frequencies of human blood lymphocytes that were obtained from both normal healthy persons and colorectal cancer patients, were observed after treatment with MMC.
Titanium alloy surface properties have an essential role in the interaction of dental implants with bone, and alteration of the surface of the implant could improve osseointegration. This study was designed to investigate the effect of different heat treatment temperatures on titanium alloy surface properties for dental implants. The effect of different temperatures of heat treatment (750°C, 850°C, 950°C and 1050°C) were investigated on the surface topography, surface chemistry, titanium oxide layer thickness, blood contact angle, & blood drop diameter of titanium alloy. The disks were prepared from titanium alloy (Ti-6Al-4V) and the samples were divided into five groups depending on the different temperatures of heat treatment. The hea
... Show MoreThe efficiency of internal combustion engines (ICE) is usually about thirty percent of the total energy of the fuel. The residual energy is lost in the exhaust gas, the lubrication, and the cooling water in the radiators. Recently much of the researcher’s efforts have focused on taking advantage of wasted energy of the exhaust gas. Using a thermoelectric generator (TEG) is one of the promising ways. However, TEG depends entirely on the temperature difference, which may be offered by the exhaust muffler. An experimental test has been conducted to study the thermal performance of a different muffler internal design. The researchers resort to the use of lost energy in an ICE using TEG, which is one of the ways to take adv
... Show More
The present investigation deals with experimental study of three-phase direct-contact heat exchanger, for water-Freon R11 system, where water is the continuous phase (liquid) and Freon R11 (liquid-gas) is the dispersed phase. The test section consisted of a cylindrical Perspex column with inner diameter 8cm and 1.2m long, in which, water was to be confined. Liquid Freon R11 drops were injected into the hot water filled column, through a special design of distributors at the bottom of the column. The liquid Freon R11 drops rose on their way up and evaporated into two-phase bubbles at atmospheric pressure. The study was devoted to express the effect of process variables such as c
... Show MorePurpose: The research aims to diagnose the current availability of knowledge workers characteristics and the role of these characteristics in knowledge acquision in the city of Sulaimaniya Directorate of Electricity, and to identify the differences between personal and occupational characteristics of a sample of research and its impact on the availability of such properties.Design/methodology/approach :to achieve the objectives of the research questionnaire was developed especially for it and then distributed to a sample of engineers and technicians working in the Directorate of Electricity city of Sulaimaniya, where the sample of the research (52) respondents.
Findings: the most important conclusions reached
... Show More
Background: osteoporosis is characterized by a reduction in bone mineral density, skeletal microstructure breakdown, increased bone fragility, and fracture susceptibility. Osteopenia is the preceding step to osteoporosis because it causes a decrease in bone mass, osteoporosis reduces a person's quality of life. Periostin (encoded by Postn), its name is derived from the fact that it was first detected in periosteal osteocytes and osteoblasts. Periostin deficiency has been linked to osteoporosis and weak bones. Study objectives: The purpose of this study was to determine periostin levels in serum of Iraqi patients with osteoporosis and osteopenia, and it is also possible to consider periostin as a diagnostic factor to follow the progression o
... Show MoreObjective(s): The present study aims at studying the relationship between immunoglobulin IgG, IgA,
IgM , as well as to C-3 and C-4 in brain tumours patients immunity (meningioms and gliomas).
Methodology: Forty sera of brain tumour patients were included 20 glioma and 20 meningioma was
tested to determine the levels of IgM, IgG IgA, C-3 and C-4 by using single radial immune-diffusion
technique and compared with 20 apparently healthy blood donors.
Results: The study revealed a significant decreasing in IgG levels in glioma as compare to meningioma
and control. The concentration of two other serum immunoglobulins and complement in both
meningioma and glioma show no significant differences with those in control group.
Background: Dental implant surface technologies have been evolving rapidly to enhance a more rapid bone formation on their surface and improve implant therapy.Implant threads should be designed to increase surface contact areathat induced better stability. In addition, implant surface coating with Flaxseed was used to enhance bone formation at the bone-implant interface. Materials and methods: Ninety-six commercially pure titanium (CpTi) screws were implanted in rabbits' tibiae and divided into three groups as dual-threaded group, flaxseed-coated group and control group. All groups were evaluated mechanically, histologically and radiographically after each healing periods (2, 4, 6 and 8) weeks and the resulting data were statistically analy
... Show MoreThe performance of job effectively requires narrowing the meaningful routine activities and attempting employing the job procedures in favor of public welfare through adding the green impact as well as removing them from the red tapes which reflect the firmness of procedures, to enable the job parties to make their job independently, and pushing them to gain priority in the competition layer. This is not attaining easily amidst the regulatory problems expressed by the complication of procedures, the thing which make identifying the problem of the study through the following question:
Should we make the complex of procedures and their firmness a way to adopt the idea of the green regulatory tapes supportin
... Show More