BACKGROUND: Acute coronary syndrome (ACS) is the clinical manifestation of acutely diminished coronary arterial blood supply. The rate of increase of intraventricular pressure during isovolumetric contraction (left ventricular dP/dt) represents the rate of change of pressure during ejection. OBJECTIVE: The aim of this study is to evaluate the usefulness of the rate of increase of intraventricular pressure during isovolumetric contraction (dP/dt) in assessment of left ventricular function in patients with acute coronary syndrome and its relation to certain clinical and echocardiographic features. PATIENTS AND METHODS: The study is a cross sectional study including 50 patients with an established diagnosis of acute coronary syndrome. The study was performed in Baghdad Teaching Hospital during the period between 2/2/2013 and 5/3/2014. History was taken from all patients and recoded using a specially prepared questionnaire paper. Left ventricular internal dimensions at end diastole (LVIDd) and end systole (LVIDs) were measured using M-mode echocardiography to asses left ventricular systolic function (ejection fraction). Pulse Doppler tracing of the transmitral flow velocities and tissue Doppler image (TDI) mitral annular velocities were obtained from the apical four-chamber view to assess left ventricular diastolic function. Doppler-derived dP/dt was determined from mitral regurgitation (MR) spectral flow RESULTS: The study included 50 patients (31 males and 19 females, mean age of 65.26 ± 5 years). Low dP/dt values were found in 42 patients (84%). Low dP/dt values were found more in the age group (51-60 yrs) (p value < 0.05). The mean age of patients with low dP/dt (<1000) was (65.62 ± 5yrs) and that of patients with normal dP/dt (≥ 1000) was (63.38 ± 5 yrs) with no significant difference (p value > 0.05). Low dP/dt value was significantly associated with smoking and positive family history and not significantly associated with male sex, hypertension, and diabetes mellitus. No significant association was found between low dP/dt value and type of presentation of acute coronary syndrome (p value > 0.05) or ejection fraction (p value > 0.05). It was significantly associated with LV diastolic dysfunction, left atrial size, left atrial pressure, and left ventricular size (p value < 0.05). CONCLUSION: The use of dP/dt is useful for evaluating left ventricular function in patients with acute coronary syndrome.
We examine 10 hypothetical patients suffering from some of the symptoms of COVID 19 (modified) using topological concepts on topological spaces created from equality and similarity interactions and our information system. This is determined by the degree of accuracy obtained by weighing the value of the lower and upper figures. In practice, this approach has become clearer.
In this study, the researcher aimed to define and measure the relevance and effect of the governmental organizations in complying with Iraqi Ministry of Transportation's requirements towards achieving the social responsibility, embodied in the ten commandments of the United Nations Findings displayed the availability of realization regarding organization managers towards social responsibility with their various capabilities and tendencies in relation with the representing entries of those Ten Commandments.The study showed the relation between the effectiveness of those organizations and dimensions of the ten commandments of social responsibility, with the existence of a significant effect for the said effectiveness on achiev
... Show MoreThis research aims to introduce a new technique-off-site and self-form segmental concrete masonry arches fabrication, without the need of construction formwork or centering. The innovative construction method in the current study encompasses two construction materials forms the self-form masonry arches, wedge-shape plain concrete voussoirs, and carbon fiber-reinforced polymer (CFRP) composites. The employment of CFRP fabrics was for two main reasons: bonding the voussoirs and forming the masonry arches. In addition, CFRP proved to be efficient for strengthening the extrados of the arch rings under service loadings. An experimental test was conducted on four sophisticated masonry arch specimens. The research parameters were the Keystone thic
... Show MoreBackground: Orthodontic tooth movement is characterized by tissue reactions, which consist of an inflammatoryresponse in periodontal ligament and followed by bone remodeling in the periodontium depending on the forces applied. These processes trigger the secretion of various proteins and enzymes into the saliva.The purpose of thi study was to evaluate the activity of alkaline phosphatase (ALP) in saliva during orthodontic tooth movement using different magnitude of continuous orthodontic forces.
Materials and Methods: Thirty orthodontic patients (12 males and 18 females) aged 17-23 years with class II division I malocclusion all requiring bilateral maxillary first premolar extractions were randomly divided into three groups according t
Folic acid and multivitamin tablets containing Aspergillus flavus Penicillia spp. and Cladosporia spores were prepared at a compression pressure of 148 MN/m2 and stored at 35°C under different relative humidifies (75,85, and 95)% within air tight containers, to study the effect of storage condition on them, as well as ,the estimation of the microbial level of the raw materials intended to be used in the two kinds of tablets . Result showed that some raw materials derived from natural origin were heavily contaminated with microorganism compared to that of synthetic origin ,the results also indicated the effect of relative humidity , types of fungal spore , and the hygroscopic nature of exicpient upon survival. Multivit
... Show MoreBackground: The preparation of Platelet-rich plasma (PRP) is minimally invasive way, simple, low cost to obtain natural autologous growth factors and is now being widely used in different fields of medicine for its ability to increase the regeneration potential of tissue. The aim of this study was to investigate the effect of local application of autologous PRP gel on acceleration rate of osseointegration period by clinical assessment accomplished by determining the changes in implant stability during 3 months healing period using resonance frequency analysis (RFA). Materials and methods: A total of 28 dental implants were inserted in edentulous maxillae or mandibles of 13 patients using a split mouth design, i.e. each patient was received
... Show Moreبهذا البحث نقارن معاييرالمعلومات التقليدية (AIC , SIC, HQ , FPE ) مع معيارمعلومات الانحراف المحور (MDIC) المستعملة لتحديد رتبة انموذج الانحدارالذاتي (AR) للعملية التي تولد البيانات,باستعمال المحاكاة وذلك بتوليد بيانات من عدة نماذج للأنحدارالذاتي,عندما خضوع حد الخطأ للتوزيع الطبيعي بقيم مختلفة لمعلماته
... Show MoreThis study aimed to conduct a comparative analysis of seven calliphorid species of third- instar larvae that were collected from central Iraq. The purpose was to morphologically characterize these species and develop an identification key to differentiate them from closely related species. Scanning Electron Microscope (SEM) graphical images and high-resolution traditional optical microscopes were used to analyze the morphological characteristics of the species Calliphora vomitoria (Linnaeus, 1758), C. vicina Robineau-Desvoidy, 1830, Chrysomya albiceps (Widemann, 1819), Ch. rufifacies (Macquart, 1844), Ch. megacephala (Fabricius, 1794), Lucilia cuprina (Wiedemann, 1830), and L. sericata (Meigen, 1826). An identification key was const
... Show MoreSheets of Epoxy (EP) resin with addition of TiO2 of grain size (1.5μm, and 50nm) and weight percentage (1%, 3%, and 5%) were prepared. Discs of 20mm diameter and 3mm thickness were cut for dielectric measurements. Dielectric properties (dielectric constant, dispassion factor and electrical conductivity) over the frequency range 102 -106 Hz were measured.
Comparison was made between the effect of micro and nano particles of TiO2 on the dielectric properties of EP composites with different weight percentage. Epoxy composites with micro sized particles of TiO2 were observed to have the better values of dielectric properties.