BACKGROUND: Acute coronary syndrome (ACS) is the clinical manifestation of acutely diminished coronary arterial blood supply. The rate of increase of intraventricular pressure during isovolumetric contraction (left ventricular dP/dt) represents the rate of change of pressure during ejection. OBJECTIVE: The aim of this study is to evaluate the usefulness of the rate of increase of intraventricular pressure during isovolumetric contraction (dP/dt) in assessment of left ventricular function in patients with acute coronary syndrome and its relation to certain clinical and echocardiographic features. PATIENTS AND METHODS: The study is a cross sectional study including 50 patients with an established diagnosis of acute coronary syndrome. The study was performed in Baghdad Teaching Hospital during the period between 2/2/2013 and 5/3/2014. History was taken from all patients and recoded using a specially prepared questionnaire paper. Left ventricular internal dimensions at end diastole (LVIDd) and end systole (LVIDs) were measured using M-mode echocardiography to asses left ventricular systolic function (ejection fraction). Pulse Doppler tracing of the transmitral flow velocities and tissue Doppler image (TDI) mitral annular velocities were obtained from the apical four-chamber view to assess left ventricular diastolic function. Doppler-derived dP/dt was determined from mitral regurgitation (MR) spectral flow RESULTS: The study included 50 patients (31 males and 19 females, mean age of 65.26 ± 5 years). Low dP/dt values were found in 42 patients (84%). Low dP/dt values were found more in the age group (51-60 yrs) (p value < 0.05). The mean age of patients with low dP/dt (<1000) was (65.62 ± 5yrs) and that of patients with normal dP/dt (≥ 1000) was (63.38 ± 5 yrs) with no significant difference (p value > 0.05). Low dP/dt value was significantly associated with smoking and positive family history and not significantly associated with male sex, hypertension, and diabetes mellitus. No significant association was found between low dP/dt value and type of presentation of acute coronary syndrome (p value > 0.05) or ejection fraction (p value > 0.05). It was significantly associated with LV diastolic dysfunction, left atrial size, left atrial pressure, and left ventricular size (p value < 0.05). CONCLUSION: The use of dP/dt is useful for evaluating left ventricular function in patients with acute coronary syndrome.
This study aims at identifying the reality of alternative assessment for teachers of the first cycle of the basic education in the Sultanate of Oman with respect to the degree of teachers' use of alternative assessment strategies, level of self-efficacy for alternative assessment strategies, and attitude towards alternative assessment, and their relationship with other variables. To achieve the aims of the study, a descriptive research approach was utilized. A 5-point self-rated questionnaire was developed. It consists of three sections: Actual use of alternative assessment strategies (21 items), self-efficacy for alternative assessment strategies (21 items), and attitude towards alternative assessment (27 items). The psychometric proper
... Show MoreBackground: Laparoscopic cholecystectomy (LC) has become the treatment of choice for elective cholecystectomy.Objectives: To evaluate the safety and feasibility of early LC for AC and to compare the results with delayed LC.Methods: A prospective study done from April 2011 to October 2013, 88 patients with diagnosis of AC were divided randomly into two groups according to the mode of treatment; (early group n=40) treated by early LC within first 72 hours or (delayed group, n=48) initial conservative treatment for 4-6 weeks, followed by delayed LC.Results: There was no difference between the two groups (early & delayed LC), operating time (early 80min, delayed70min), conversion rate (early 7.5%, delayed 6.25%),postoperative complicatio
... Show MoreThis work studies the impact of input machining parameters of Electrical Discharge Machining (EDM) on the machining process performance. Tool steel O1 was selected as the workpiece material, copper as the electrode material, and kerosene as the dielectric medium. Experimental runs have been carried out with a Design of Experiment (DOE) technique. Twenty tests are accomplished with the current range of (18 to 24 Ampere), a pulse duration range of (150 to 200 µs), and a pulse-off time range of (25 to 75 µs). Based upon the experimental study's output results, the EDM parameter's effect (voltage of power supply, discharge current, pulse duration, and pulse pause interval) on the responses of the process represented by sur
... Show MoreBackground: Despite the fact that the exact architecture and orientation of ventricular myocardium are critical to cardiac functions either in health or disease, it is still debated.
Objectives: Anatomical demonstration of the ventricle myocardium (VM)as a single, long and continuous muscular sheet and this muscular sheet can be dived into 3-segments. As a new anatomical concept the left ventricle is a triple layers wall; whether the right ventricle is a single layer wall.Histological demonstration of different directions of muscle-fibers at each layer of ventricular myocardium.
Type of the study: Cross- sectional study.
Methods: In this study 100
... Show MoreObjective(s): To find out the incidence Rate of abortions in pregnant women Admitted Maternal and pediatric Hospitals at Al-Diwaniyah City and to identify the relationship between the incidence rate of abortion and the associated risk factors that led to the occurrence of abortion.
Methodology: A descriptive study was conducted to identify the Incidence Rate of Abortions and its Associated Factors among Women at AL-Diwaniyah City’s Maternity and pediatric Hospital from 16 September 2020 to 16 March 2021 . The sample study includes (100) pregnant women with abortion out of (3800) pregnant women. The data was collected by means of a questionnaire through a personal intervie
... Show MoreBackground: Imaging has a critical role in the diagnosis and evaluation of cardiac diseases, beginning with chest radiography and fluoro-scopy and progressing to coronary angio-graphy, echocardiography, nuclear medicine and recently multidetector computed tomo-graphy (MDCT) as well as magnetic resonance (MR) imaging
Objective: To highlight the role of Multi-detector CT in the evaluation of coronary artery disease and its importance of being noninvasive diagnostic technique.
Methods: A cross sectional study for 20 patients. Patients were asked to fast 6 hours prior to the examination and the patients with heart rates above 65 beats per minute were given cardio-
... Show MoreLactobacillus Plantarum and Lactobacillus rhamnosus GG were encapsulated using 3% of alginate via extrusion technique. And the probiotics capsules produced were further coated used 1% chitosan to increase the survival of probiotics, and evaluation of The heat resistance of the slow pasteurization and fast pasteurization for Lb,pla and Lb.GG for control and bacteria coated one layer and bacteria coated two layer at 63°C/ 30 minutes and 72°C/ 15 seconds. The results indicate that the Probiotic coated two layer are more resistant to pasteurization temperatures at 63°C/ 30 minutes and 72°C/ 15 seconds than the Probiotic coated one layer. While the results of the control follow a significant reduction for viability of cell toward pasteuri
... Show MoreStick- slip is the continuous stopping& release of the Bit/BHA due to the irregular down-hole rotation prompted by the existing relationship between the friction torque and the torque applied from the surface to free the bit.
Friction coefficient between BHA and wellbore is the main player of stick slip amount, which can be mitigated by support a good lubricators as additives in drilling mud.
Mathematical (or empirical) solves should be done through adjusting all parameters which supposed to reduce stick- slip as low as possible using different models, one of the main parameters is drilling mud. As per Nanoparticles drilling fluid is a new technology that offers high performance
... Show MoreThe power of advertising is immense. Producers of commercial goods and services routinely pour vast sums into promoting their wares through the advertising media, knowing that a successful campaign can win them vital market share , and that failure to advertise effectively can have devastating results . The function of advertising is promotional ; to draw our attention. In order to achieve this function it must reach its target audience , then capture that audience with a message that is both attractive and memorable.
From a linguistic point of view, the language of advertising must be informative, instructive , distinctive and persuasive . It must employ&nb
... Show More