On the Use of 6th-Order Tunable Complementary Metal-Oxide-Semiconductor Varactor based Filter in Ultra-Wideband Low Noise Amplifier
...Show More Authors
Background:

The plethora of the emerged radio frequency applications makes the frequency spectrum crowded by many applications and hence the ability to detect specific application’s frequency without distortion is a difficult task to achieve.

Objective:

The goal is to achieve a method to mitigate the highest interferer power in the frequency spectrum in order to eliminate the distortion.

Method:

This paper presents the application of the proposed tunable 6th-order notch filter on Ultra-Wideband (UWB) Complementary Metal-Oxide-Semiconductor (CMOS) Low Noise Amplifier (LNA) utilising self-forward body bias (SFBB).

Results:

The proposed filter presents 23.5dBm minimum interferer rejection (IR) and attenuates the interferer signal from -43dBm to -67dBm at frequency 5.17GHz. In addition, the maximum IR is 40dBm and attenuates the interferer signal from -41dBm to -81dBm at frequency 5.785GHz. The proposed filter provides coarse tuning with frequency spacing (10MHz) and soft tuning with frequency spacing (1MHz). The UWB CMOS LNA consumes only 5.22mW from a supply voltage of 1.2V and presents a maximum gain of 14dB at frequency 6.25GHz in the -3dB bandwidth from 4.75GHz to 7.5GHz. In addition, the average noise figure is 3.1dB and the input insertion losses (S11) is less than -12dB along the designed bandwidth. The simulation is performed in Advanced Design System (ADS2016.01) software utilising 180nm Taiwan Semiconductor Manufacturing Company (TSMC) Berkeley Short-channel Insulated Gate Field Effect Model (BSIM3v3) model files.

Conclusion:

The proposed method achieves high interferer power rejection with both soft and coarse tuning.

Scopus Crossref
Publication Date
Sun Mar 13 2011
Journal Name
Baghdad Science Journal
Use of Coliphages as an indicators of enteroviruses and faecal pollution in Water
...Show More Authors

In spite of increasing clinical cases which caused by enteroviruses transferred by water and no documents about entericviruses in the Iraqi water standards. The use of coliphages as an indicator of enteroviruses and fecal pollution were suggested two procedures were applied . The first is Two-Step Enrichment Method and the second is Single Agar Layer Method. Both methods gives good results in Identification of coliphages through testing fifty different water samples (Tap water, Surface water and Bottled water) the study shows the presence of coliphages in fourteen samples.

View Publication Preview PDF
Crossref
Publication Date
Wed Aug 31 2022
Journal Name
Iraqi Journal Of Science
Accumulation Detection of Cadmium in some land-use soil of Baghdad city, Iraq
...Show More Authors

    This study aims to detect cadmium accumulation in the soil of Baghdad. Twenty soil samples were collected randomly during November 2020 to cover the study area, emphasizing the nature of each area (agricultural, commercial, industrial, residential, roadside, and waste dumping sites). All soil samples were subjected to geochemical analysis using atomic absorption spectrometry (ASS) to determine the concentration of cadmium in Baghdad soil. The laboratory data was utilized to design the spatial analysis map using Arc GIS 10.4.1 to investigate the spatial distribution of cadmium. The results demonstrated that the total content of cadmium in the study area ranged from 0.121to 1.78 mg/kg. All results of cadmium concentrations are withi

... Show More
View Publication Preview PDF
Scopus (8)
Crossref (1)
Scopus Crossref
Publication Date
Wed Jun 29 2022
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Measuring Dyes Concentration Using a Low-Cost Visible-Light Spectrophotometer
...Show More Authors

   A low-cost, RGB LED-based visible-light spectrophotometer was designed to measure dyes concentration. Dyes are widely used as indicators or coloring agents in different applications and knowing their concentration is an essential part for many studies. The proposed spectrophotometer provides many functionalities that clones the traditional expensive spectrophotometers for a budged price under $50. It was aimed to provide a versatile tool for instructors and educators to teach their students the fundamental concepts behind spectrophotometry. Malachite green, methyl red, and methyl orange dyes were chosen to be good samples to show the integrity of the proposed spectrophotometer in terms of accuracy, repeatability, and sensitivity as

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Apr 28 2023
Journal Name
Mathematical Modelling Of Engineering Problems
Using Crushed Glass with Sand as a Single and Dual Filter Media for Removal of Turbidity from Drinking Water
...Show More Authors

View Publication
Publication Date
Wed Feb 05 2025
Journal Name
Journal Of Engineering
Testing and Commissioning of a Low-Speed Wind Tunnel (LSWT) Test Section
...Show More Authors

The calibration of a low-speed wind tunnel (LSWT) test section had been made in the present work. The tunnel was designed and constructed at the Aerodynamics Lab. in the Mechanical Engineering Department/University of Baghdad. The test section design speed is 70 m/s. Frictional loses and uniformity of the flow inside the test section had been tested and calibrated based on the British standards for flow inside ducts and conduits. Pitot-static tube, boundary layer Pitot tube were the main instruments which were used in the present work to measure the flow characteristics with emphasize on the velocity uniformity and boundary layer growth along the walls of the test section. It is found that the maximum calibrated velocity for empty test sect

... Show More
View Publication
Publication Date
Sun Sep 05 2010
Journal Name
Baghdad Science Journal
Design of six electrode Enzial electrostatic lens low aberrations for electron gun
...Show More Authors

A computerized investigation has been carried out on the design of six electrodes electrostatic lenses used in electron gun application. The Finite-Element Method (FEM) was used in the solution of Laplace equation for determine the axial potential distribution. The electron trajectory under zero magnification condition. The optical properties, spherical and chromatic aberrations, the object and image focal length and object and image position are calculated. A very good futures for the electron gun with these lenses have been computed where are a beam current of 8.7*10-7A can be supplied using cathode tip of radius 10nm.

View Publication Preview PDF
Crossref
Publication Date
Sat Feb 02 2019
Journal Name
Journal Of The College Of Education For Women
Design of an Electron Gun Using two Electrod Low Aberration Immersion Lens
...Show More Authors

Abstract
A two electrode immersion electrostatic lens used in the design
of an electron gun, with small aberration, has been designed using
the finite element method (FEM). By choosing the appropriate
geometrical shape of there electrodes the potential V(r,z) and the
axial potential distribution have been computed using the FEM to
solve Laplace's equation.
The trajectory of the electron beam and the optical properties of
this lens combination of electrodes have been computed under
different magnification conditions (Zero and infinite magnification
conditions) from studying the properties of the designed electron
gun can be supplied with Abeam current of 5.7*10-6 A , electron
gun with half acceptance

... Show More
View Publication Preview PDF
Publication Date
Thu Jan 07 2021
Journal Name
Indian Journal Of Forensic Medicine & Toxicology
Relationship of Low Maternal Vitamin D3 Level and Adverse Early Neonatal Outcomes
...Show More Authors

View Publication
Scopus (3)
Crossref (1)
Scopus Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Journal Of Mechanical Engineering Research And Developments
Real-time control of robotic hand by human hand at low cost
...Show More Authors

Scopus (3)
Scopus
Publication Date
Sun Jul 09 2023
Journal Name
Journal Of Engineering
Testing and Commissioning of a Low-Speed Wind Tunnel (LSWT) Test Section
...Show More Authors

The calibration of a low-speed wind tunnel (LSWT) test section had been made in the present work. The tunnel was designed and constructed at the Aerodynamics Lab. in the Mechanical Engineering Department/University of Baghdad. The test section design speed is 70 m/s. Frictional loses and uniformity of the flow inside the test section had been tested and calibrated based on the British standards for flow inside ducts and conduits. Pitot-static tube, boundary layer Pitot tube were the main instruments which were used in the present work to measure the flow characteristics with emphasize on the velocity uniformity and boundary layer growth along the walls of the test section. It is found that the maximum calibrated velocity for empty test s

... Show More
View Publication Preview PDF
Crossref (1)
Crossref