Microbubble Distillation for Ethanol-Water Separation
...Show More Authors

In the current study, a novel approach for separating ethanol-water mixture by microbubble distillation technology was investigated. Traditional distillation processes require large amounts of energy to raise the liquid to its boiling point to effect removal of volatile components. The concept of microbubble distillation by comparison is to heat the gas phase rather than the liquid phase to achieve separation. The removal of ethanol from the thermally sensitive fermentation broths was taken as a case of study. Consequently the results were then compared with those which could be obtained under equilibrium conditions expected in an “ideal” distillation unit. Microbubble distillation has achieved vapour compositions higher than that which could be obtained under traditional equilibrium conditions. The separation was achieved at liquid temperature significantly less than the boiling point of the mixture. In addition, it was observed that the separation efficiency of the microbubble distillation could be increased by raising the injected air temperature, while the temperature of the liquid mixture increased only moderately. The separation efficiency of microbubble distillation was compared with that of pervaporation for the recovery of bioethanol from the thermally sensitive fermentation broths. The technology could be controlled to give high separation and energy efficiency. This could contribute to improving commercial viability of biofuel production and other coproducts of biorefinery processing.

Scopus Crossref
View Publication
Publication Date
Sun Jul 09 2023
Journal Name
Journal Of Engineering
Corrosion Study of the Injection Equipments in Water in Al-Ahdeb Wells ‐Iraq
...Show More Authors

Water injection equipments such as pipelines, which are used in the second recovery of oil in the Al-Ahdeb wells, suffer from the corrosion in water during maintaining vacuum deoxygenated tower that used to decrease concentration of the dissolved oxygen gas in the water from 6.2-9.1 ppm to o.5 ppm. This study involved calculation the corrosion rates of the internal surfaces of the
pipelines either during operation of the vacuum unit or when the tower out of operation. Finally, find the solution by one of the following suggestions. In the first suggestion removal of the dissolved O2 from water is achieved by increasing the dosage of the oxygen scavenger (sodium sulphite). The second suggestion involves removing the dissolved O2 from w

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Thu Jun 30 2016
Journal Name
Iraqi Geological Journal
ASSESSMENT OF GROUNDWATER QUALITY USING WATER QUALITY INDEXIN, AL-HAWIJA AREA, NORTHERN IRAQ
...Show More Authors

The quality of groundwater in the Al-Hawija area was assessed using a water quality index. Data of nine physico-chemical parameters of 28 groundwater wells were used to calculate the water quality index (WQI). A heterogeneous water quality was reported, where in close proximity to the Lesser Zab River (LZR), it has low WQI values and permissible for human consumptions due to the dilution processes by fresh water; whereas, it becomes deteriorated in areas located far away the river. The values of WQI ranges from 22 to 336, indicating a good to very poor groundwater quality.

View Publication
Crossref (3)
Crossref
Publication Date
Fri Jan 01 2021
Journal Name
Materials Today: Proceedings
Solving high sulfate content of sand used in concrete by magnetic water process
...Show More Authors

View Publication
Scopus (6)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Thu Jan 01 2015
Journal Name
Journal Of Engineering
Corrosion Study of the Injection Equipments in Water in Al-Ahdeb Wells ‐Iraq
...Show More Authors

Water injection equipments such as pipelines, which are used in the second recovery of oil in the Al-Ahdeb wells, suffer from the corrosion in water during maintaining vacuum deoxygenated tower that used to decrease concentration of the dissolved oxygen gas in the water from 6.2-9.1 ppm to o.5 ppm. This study involved calculation the corrosion rates of the internal surfaces of the pipelines either during operation of the vacuum unit or when the tower out of operation.  Finally, find the solution by one of the following suggestions. In the first suggestion removal of the dissolved O2 from water is achieved by increasing the dosage of the oxygen scavenger (sodium sulphite). The second suggestion involves re

... Show More
View Publication
Publication Date
Tue Apr 01 2025
Journal Name
Iop Conference Series: Earth And Environmental Science
Nutrient and Water Use Efficiency of Broccoli Cultivated Hydroponically on Alternative Solution ABEER
...Show More Authors
Abstract<p>A Field experiment was conducted in Horticulture and Landscape Department, College of Agricultural Engineering Sciences, University of Baghdad, Al-Jadriah during fall 2019-2020 to study nutrient and water use efficiency of broccoli cultivated hydroponically on alternative solution ABEER. Nested design with three replications adopted in the experiment, each of them included in main plot the first factor, which is gas enrichment (O<sub>2</sub> and O<sub>3</sub>), Then levels of second factor were randomly distributed within each replicate, which included spraying with plants extracts which was Moringa leaves extract and Coconut water at two concentrations 2, 4 %and 5</p> ... Show More
View Publication
Scopus Crossref
Publication Date
Mon May 01 2023
Journal Name
Journal Of Engineering
Experimental Evaluation of PV Panel Efficiency Using Evaporative Cooling Integrated with Water Spraying
...Show More Authors

In this work, an inventive photovoltaic evaporative cooling (PV/EC) hybrid system was constructed and experimentally investigated. The PV/EC hybrid system has the prosperous advantage of producing electrical energy and cooling the PV panel besides providing cooled-humid air. Two cooling techniques were utilized: backside evaporative cooling (case #1) and combined backside evaporative cooling with a front-side water spray technique (case #2). The water spraying on the front side of the PV panel is intermittent to minimize water and power consumption depending on the PV panel temperature. In addition, two pad thicknesses of 5 cm and 10 cm were investigated at three different water flow rates of 1, 2, and 3 lpm. In Case #1,

... Show More
View Publication Preview PDF
Scopus (11)
Crossref (10)
Scopus Crossref
Publication Date
Mon Nov 01 2021
Journal Name
Iop Conference Series: Earth And Environmental Science
A study of Irrigation Water Pollution By Some Heavy Metals in Baghdad Governorate
...Show More Authors
Abstract<p>A study of irrigation water was conducted Baghdad city to find out extent of its pollution by some heavy metals (Pb, Cd, Ni, Co, CU, Cr, Zn and Fe). Water samples were collected randomly from different sources (river, well and stream). Results showed that the concentration of studied heavy metals were as follows: Lead between 0.43-11.75 mg L<sup>-1</sup>, Cadmium between 0.01-0.95 mg L<sup>-1</sup>, Nickel between 0.008-0.46 mg L<sup>-1</sup>, Cobalt between Nil - 0.185 mg L<sup>-1</sup>, Copper is between 0.326 - 1.58 mg L<sup>-1</sup>, Chromium is between Nil-0.068 mg L<sup>-1</sup>, Zinc 0.398-1.182 mg L<sup>-1</sup>, as for Iro</p> ... Show More
View Publication
Scopus (5)
Crossref (4)
Scopus Crossref
Publication Date
Wed Apr 15 2026
Journal Name
Experimental And Theoretical Nanotechnology
Remote sensing analysis: A decade of water surface changes in Lake Hamrin, Iraq
...Show More Authors

The study of Lake Hamrin is of enormous importance in understanding changes in water levels and their impact on the local environment. It helps to clarify the role of climatic and human factors in the decline of its water resources from 2013 to 2023 in order to ensure sustainable solutions. Satellite imagery from Landsat 8 is used, and processing is performed using ArcGIS Pro and ENVI. The normalized vegetation index (NDVI) is applied to show the changes in the vegetation cover and reveal the amount of change in the surface water area of the lake. It is noted that the water area changes in one year as it increases in the rainy season and decreases in the summer, and it also varies from one year to another with the difference in the amount o

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Mon Oct 03 2016
Journal Name
International Journal Of Civil Engineering
Development of Excess Pore Water Pressure around Piles Excited by Pure Vertical Vibration
...Show More Authors

View Publication
Scopus (19)
Crossref (13)
Scopus Clarivate Crossref
Publication Date
Thu Feb 01 2024
Journal Name
Heliyon
Removal of amoxicillin from contaminated water using modified bentonite as a reactive material
...Show More Authors

This study concerns the removal of a trihydrate antibiotic (Amoxicillin) from synthetically contaminated water by adsorption on modified bentonite. The bentonite was modified using hexadecyl trimethyl ammonium bromide (HTAB), which turned it from a hydrophilic to a hydrophobic material. The effects of different parameters were studied in batch experiments. These parameters were contact time, solution pH, agitation speed, initial concentration (C0) of the contaminant, and adsorbent dosage. Maximum removal of amoxicillin (93 %) was achieved at contact time = 240 min, pH = 10, agitation speed = 200 rpm, initial concentration = 30 ppm, and adsorbent dosage = 3 g bentonite per 1L of pollutant solution. The characterization of the adsorbent, modi