Preferred Language
Articles
/
hxdH35IBVTCNdQwC78Lw
Evaluating dental implant stability using three devices Osstell<sup>®</sup>, Periotest<sup>®</sup>, and AnyCheck<sup>®</sup>: a clinical study
...Show More Authors

Introduction: Implant stability is usually measured with resonance frequency analysis (RFA) and damping capacity assessment (DCA). This study aimed to measure primary and secondary stabilities using 3 devices that are based on these methods, namely; RFA (Osstell®) and DCA (Periotest® and AnyCheck®) to assess the correlations of the measurements obtained by these devices and the correlations between implant stability and insertion torque. Material and Methods: This observational prospective study included 35 dental implants. The implant stability was measured using the 3 devices. Mann–Whitney U test and unpaired t-test assessed the relationship between implant stability and insertion torque, while the Spearman and Pearson correlations measured the correlation between readings collected via the 3 devices for the primary and secondary stabilities. Results: For the primary stability, there was a strong positive correlation between Osstell® and AnyCheck® and moderate negative correlations between Periotest® and both Osstell® and AnyCheck®. While for the secondary stability, strong correlations with similar patterns were observed among the 3 devices. The stability measurements showed significant relationships with the insertion torque. Conclusions: The 3 devices are reliable in measuring implant stability; also, high insertion torque can lead to improved implant stabilities (primary and secondary).

Scopus Crossref
View Publication
Publication Date
Sun Aug 09 2015
Journal Name
No
Stability and Instability of Some Types of Delay Differential Equations
...Show More Authors

Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
Stability constants of iron(II) supported and lead(II) complexes
...Show More Authors

Overall enthalpy and entropy of complex formation were calculated from stability constant measurements at different tempreture also experimental results

View Publication Preview PDF
Publication Date
Fri Sep 15 2023
Journal Name
Journal Of Baghdad College Of Dentistry
FEM: Mono-implant cement retained crown with two different adhesive materials
...Show More Authors

Background: The finite element method (FEM) is expected to be one of the most effective computational tools for measuring the stress on implant-supported restorations. This study was designed using the 3D-FEM to evaluate the effect of two adhesive luting types of cement on the occlusal stress and deformation of a hybrid crown cemented to a mono-implant. Materials and Method: The mono-screw STL file was imported into the CAD/CAM system library from a database supported by De-Tech Implant Technology. This was to assist in the accurate reproduction of details and design of a simulated implant abutment. Virtually, a digital crown was designed to be cemented on an abutment screw. A minimum occlusal thickness of 1mm and marginal fitting of 1.2

... Show More
View Publication Preview PDF
Scopus (2)
Crossref (2)
Scopus Crossref
Publication Date
Tue Jan 17 2023
Journal Name
Karbala International Journal Of Modern Science
Biofunctionalization of polyetheretherketone implant material by bone-forming peptide-2 immobilization
...Show More Authors

Polyetheretherketone (PEEK) has favorable biomechanical properties to be used as an implant material. Unfortunately, it is hydrophobic and does not promote cellular adhesion, which could result in poor integration with bone tissue. Bio-functionalization of PEEK surface with osteogenic peptides derived from bone extracellular matrix proteins is an exciting approach to encourage bone formation around the implant. In the current study, bone-forming peptide-2 was immobilized on PEEK surface using two different methods, using dopamine and a diglycidyl ether as conjugate compounds, respectively. Peptide quantification test revealed that the two strategies resulted in the most amount of peptides were attached with 0.5 mM concentration and no furth

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (5)
Scopus Crossref
Publication Date
Fri Mar 15 2019
Journal Name
Journal Of Baghdad College Of Dentistry
The effect of 2 different techniques in second stage implant surgery
...Show More Authors

Background: Dental implant is one of the most important options for teeth replacement. In two stage implant surgery, a few options could be used for uncovering implants, scalpel and laser are both considered as effective methods for this purpose. The Aim of the study: To compare soft tissue laser and scalpel for exposing implant in 2nd stage surgery in terms of the need for anesthesia, duration of procedure and pain level assessment at day 1 and day 7 post operatively using visual analogue scale . Materials and methods: Ten patients who received bilateral implants participated after healing period completed, gingival depth over each implant was recorded and then implant(s) were exposed by either scalpel or laser with determination for th

... Show More
View Publication
Scopus (2)
Crossref (4)
Scopus Crossref
Publication Date
Tue Oct 01 2019
Journal Name
Journal Of Economics And Administrative Sciences
Employing the results of evaluating employees'performance in achieving organizational integrity Field study at the Technical Institute in Mosul
...Show More Authors

The objective of the study is to study how to employ performance evaluation in achieving organizational integrity and the impact of performance evaluation on achieving organizational integrity. In light of this, the following questions were raised:

Are the dimensions of organizational integrity available in the field in question?

In order to answer the research questions, a questionnaire questionnaire was distributed to the sample of 30 members of the teaching staff at the Technical Institute in Mosul. The three-dimensional Lycert scale was used. The statistical methods were used, ie, the frequency distribution, the computational circles, the standard deviations, Pearson), simple

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Nov 01 2017
Journal Name
Journal Of Engineering
Evaluating the Quality of Authoritative Geospatial Datasets
...Show More Authors

General Directorate of Surveying is considered one of the most important sources of maps in Iraq. It produced digital maps for whole Iraq in the last six years. These maps are produced from different data sources with unknown accuracy; therefore, the quality of these maps needs to be assessed. The main aim of this study is to evaluate the positional accuracy of digital maps that produced from General Directorate of Surveying. Two different study areas were selected: AL-Rusafa and AL-Karkh in Baghdad / Iraq with an area of 172.826 and 135.106 square kilometers, respectively. Different statistical analyses were conducted to calculate the elements of positional accuracy assessment (mean µ, root mean square error RMSE, mini

... Show More
View Publication Preview PDF
Publication Date
Fri Jan 01 2021
Journal Name
Lecture Notes In Networks And Systems
Evaluating the Efficiency of Regional Transport Network
...Show More Authors

View Publication
Scopus (1)
Scopus Crossref
Publication Date
Wed Nov 01 2017
Journal Name
Journal Of Engineering
Evaluating the Quality of Authoritative Geospatial Datasets
...Show More Authors

General Directorate of Surveying is considered one of the most important sources of maps in Iraq. It produced digital maps for whole Iraq in the last six years. These maps are produced from different data sources with unknown accuracy; therefore, the quality of these maps needs to be assessed. The main aim of this study is to evaluate the positional accuracy of digital maps that produced from General Directorate of Surveying. Two different study areas were selected: AL-Rusafa and AL-Karkh in Baghdad / Iraq with an area of 172.826 and 135.106 square kilometers, respectively. Different statistical analyses were conducted to calculate the elements of positional accuracy assessment (mean µ, root mean square error RMSE, minimum and maxi

... Show More
Crossref
Publication Date
Thu Oct 15 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Beta angle in a sample of Iraqi adults with Class I skeletal and dental relations and its correlation with other craniofacial measurements
...Show More Authors

Background: This study aimed to determine the value of Beta angle for a sample of Iraqi adults with class I skeletal and dental relations and to verify the existence of sexual dimorphism and to find out the relation between this angle and other craniofacial measurements. Materials and Methods: Sixty dental students (23 males and 37 females) with an age ranged between 20-31 years old and having class I skeletal and dental relations were chosen for this study. Each student was subjected to clinical examination and digital true lateral cephalometric radiograph. The radiographs were analyzed using AutoCAD 2007 computer program to measure the angular and linear variables. Descriptive statistics were obtained for the measurements for both genders

... Show More
View Publication Preview PDF