Preferred Language
Articles
/
hxdH35IBVTCNdQwC78Lw
Evaluating dental implant stability using three devices Osstell<sup>®</sup>, Periotest<sup>®</sup>, and AnyCheck<sup>®</sup>: a clinical study
...Show More Authors

Introduction: Implant stability is usually measured with resonance frequency analysis (RFA) and damping capacity assessment (DCA). This study aimed to measure primary and secondary stabilities using 3 devices that are based on these methods, namely; RFA (Osstell®) and DCA (Periotest® and AnyCheck®) to assess the correlations of the measurements obtained by these devices and the correlations between implant stability and insertion torque. Material and Methods: This observational prospective study included 35 dental implants. The implant stability was measured using the 3 devices. Mann–Whitney U test and unpaired t-test assessed the relationship between implant stability and insertion torque, while the Spearman and Pearson correlations measured the correlation between readings collected via the 3 devices for the primary and secondary stabilities. Results: For the primary stability, there was a strong positive correlation between Osstell® and AnyCheck® and moderate negative correlations between Periotest® and both Osstell® and AnyCheck®. While for the secondary stability, strong correlations with similar patterns were observed among the 3 devices. The stability measurements showed significant relationships with the insertion torque. Conclusions: The 3 devices are reliable in measuring implant stability; also, high insertion torque can lead to improved implant stabilities (primary and secondary).

Scopus Crossref
View Publication
Publication Date
Fri Sep 15 2017
Journal Name
Journal Of Baghdad College Of Dentistry
Assessing The Radiopacity of Three Resin Composite Materials Using a Digital Radiography Technique
...Show More Authors

Background: Radiopacity is one of the prerequisites for dental materials, especially for composite restorations. It's essential for easy detection of secondary dental caries as well as observation of the radiographic interface between the materials and tooth structure. The aim of this study to assess the difference in radiopacity of different resin composites using a digital x-ray system. Materials and methods: Ten specimens (6mm diameter and 1mm thickness) of three types of composite resins (Evetric, Estelite Sigma Quick,and G-aenial) were fabricated using Teflon mold. The radiopacity was assessed using dental radiography equipment in combination with a phosphor plate digital system and a grey scale value aluminum step wedge with thickness

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Oct 31 2013
Journal Name
Al-khwarizmi Engineering Journal
Enhancement of a Power System Transient Stability Using Static Synchronous Series Compensator SSSC
...Show More Authors

Static Synchronous Series Compensator (SSSC) is a well known device for effectively regulating the active power flow in a power system. In this paper, the SSSC linearized power flow equations are incorporated into Newton-Raphson algorithm in a MATLAB written program to investigate the control of active poweer flow and the transient stability of a five bus and a thirty bus IEEE test systems, during abnormal conduction (three phase fault near buses). A comparison of the results obtained for the base case without SSSC and with it to investigate the effectiveness of the device on both of the active power flow and the transient stability.

View Publication Preview PDF
Publication Date
Fri Sep 01 2023
Journal Name
Al-khwarizmi Engineering Journal
A Study on the Effect of Multistage Toolpath in Fabricating a Customized Cranial Implant in Incremental Sheet Metal Forming
...Show More Authors

Incremental sheet forming (ISF) process offers a high degree of flexibility in the manufacturing of different sheet parts, which makes it an ideal candidate for prototype parts as well as efficient at fabricating various customized products at low production costs compared to traditionally used processes. However, parts produced in this process exhibit notable geometrical inaccuracy and considerable thickness reduction. In this paper, the single point incremental sheet forming variant of the process has been implemented to manufacture a highly customized cranial implant starting from the computed tomography (CT) scan data of the patient's anatomy. A methodology, from the modeling to the realization of the implant, is presented and discus

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Jun 01 2022
Journal Name
Journal Of Engineering
Evaluating the Moisture Content Variation on Critical Strain of Geo-materials: A Case Study
...Show More Authors

The tunnel’s stability during construction is a very important matter. Some methods have been proposed for stability evaluation, but the hazard warning levels (HWLs) are more applicable among these methods. Despite monitoring and applying HWLs, several collapses in Shibli twin tunnels in Iran have cast doubts on the accuracy of this criterion in the presence of water. In this study, the critical strains under different water contents were measured through uniaxial compressive strength tests on 11 different shale and marl samples. A comparison of laboratory tests and numerical results shows that the influence of the moisture content on the critical strain is negligible. In addition, the results show that there is no dir

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sun Apr 20 2025
Journal Name
Journal Of Baghdad College Of Dentistry
The Soft Tissue Changes Following Orthodontic Treatment of Bimaxillary Protrusion (A Clinical and Photographical Study)
...Show More Authors

Background: Bimaxillary protrusion is considered as one of the most important causes to seek the orthodontic treatment to get better esthetics. This study aimed to test the effect of orthodontic treatment in improvement the facial esthetics. Materials and Methods: Ten Iraqi Arab females having bimaxillary protrusion based on Class I malocclusions treated with fixed orthodontic appliance and extraction of the maxillary and mandibular 1st permanent premolars. Pre and post-treatment facial profile photographs were taken for each patients and the effect of treatment was tested in comparison with the pre-treatment photographs by using seven angular measurements. Results: After treatment, the upper and lower lip projections were decreased signifi

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Sep 30 2024
Journal Name
The Scientific World Journal
Relationship Between the Level of Vitamin D3 Deficiency and Successful Osseointegration: A Prospective Clinical Study
...Show More Authors

Purpose: This study aimed to evaluate the influence of vitamin D3 levels on bone density, primary dental implant stability, and successful osseointegration.

Materials and Methods: Clinical and radiological examination with a standardized cone‐beam computed tomography (CBCT) machine and laboratory investigation for serum levels of vitamin D3 were performed for all patients. Only patients in need of single or multiple straightforward dental implant surgery in either jaw with no history of systemic disease or condition that may interfere with bone healing were included in this study to receive the dental implant by the same oral and maxillofacial surgeon, which re‐opened

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Sun Dec 06 2009
Journal Name
Baghdad Science Journal
Study of Stability of Personal Dosimeter
...Show More Authors

The study is carried out by using personal dosimeters (film badge). The films are irradiated to absorbed dose of range (0.01-10000 rad). The calibration curves are drawn by using the ordinary method taking into account the filtration effects in three regions (D (Pb/Sn),D(Du),D(300). The calibration films are stored in ambient condition. It is found that the optical density increases, which is attributed to the photodegradation of the films may induce localized states in the energy gap causing increasing in optical absorption, but optical density decreases, which attributed to the photodegradation of the films may cause some cracks at the film surface during the first month, whereas at the rest months we see clear stability in optical d

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Jan 01 2018
Journal Name
Journal Of Cosmetics, Dermatological Sciences And Applications
Pityriasis Alba versus Vitiligo Clinical and Histopathological Study
...Show More Authors

View Publication
Crossref (1)
Crossref
Publication Date
Tue Jul 01 2014
Journal Name
International Journal Of Artificial Intelligence And Mechatronics
Machining Polylines and Ellipses using Three-Axis CNC Milling Machine
...Show More Authors

CNC machine is used to machine complex or simple shapes at higher speed with maximum accuracy and minimum error. In this paper a previously designed CNC control system is used to machine ellipses and polylines. The sample needs to be machined is drawn by using one of the drawing software like AUTOCAD® or 3D MAX and is saved in a well-known file format (DXF) then that file is fed to the CNC machine controller by the CNC operator then that part will be machined by the CNC machine. The CNC controller using developed algorithms that reads the DXF file feeds to the machine, extracts the shapes from the file and generates commands to move the CNC machine axes so that these shapes can be machined.

View Publication Preview PDF
Publication Date
Sun Dec 30 2018
Journal Name
Advances In Science, Technology &amp; Innovation
Producing a Three Dimensional Model for the University of Baghdad Campus Using GIS Environment
...Show More Authors

View Publication
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref