Preferred Language
Articles
/
huaVLZ4BmraWrQ4dbF97
Biomechanical finite element analysis of a single implant threaded in anterior and posterior regions of maxilla bone
...Show More Authors

Context: The ability of implant dentistry to be a successful alternative for edentulous patients has increased in the last decade. Clinical features such as osseointegration and stability, in addition to the endurance of the integration urged the researchers towards a better understanding of the design parameters that control long term success of the implants. It is therefore necessary to quantify the effect of changing implant design parameters on interface stress distribution within the maxilla bone. Methods and Materials: A 3D-finite element study was conducted to investigate the effect of changing implant shape parameters (implant body design and implant thread depth) on stress distribution while insertion of the implant in two different regions of maxilla bone (anterior (type III bone) and posterior (type IV bone)). A 3D-CAD geometry of implant-maxilla bone was created through importing digitally visualized CT skull images of a human adult, and then converted into a workable solid body through using a collection of engineering software. Tapered and cylindrical implant models with three different implant V-shaped thread depths (0.25 mm, 0.35 mm, 0.45 mm) were threaded into maxilla bone to investigate the design parameters effect on the final stress status. The proposed implant was of commercial dimensions of 10 mm length and 4 mm in diameter. A vertical static load of 250N was directly applied to the center of the suprastructure of the implant for each model. Results: Evaluations were performed for stress distribution patterns and maximum equivalent Von Mises (EQV) stresses for implants in two regions of maxilla bone under 250N vertical static loading. The obtained results throughout this work showed that, for all models, the highest stresses were located at the crestal cortical bone around the implant neck. The von-Mises stress distribution patterns at different models were similar and higher peak von-Mises stresses of cortical bone were seen in tapered implant body compared to cylinder body in all models. Conclusions: Within the restrictions of the current model, the results obtained can be applied clinically to select properly both implant thread depth and body shape design for a foreseeable success of implant therapy.

Scopus Crossref
View Publication
Publication Date
Tue Jan 01 2019
Journal Name
International Journal Of Research In Social Sciences And Humanities
A DISCOURSE ANALYSIS STUDY OF THE TRUTH AND REALITY IN NEWS WEBSITES ABOUT THE WARIN SYRIABETWEEN AL-JAZEERA ENGLISH AND BBC WORLD
...Show More Authors

BN Rashid, International Journal of Research in Social Sciences and Humanities, 2019 - Cited by 1

View Publication
Publication Date
Mon Mar 08 2021
Journal Name
Baghdad Science Journal
the aspect of the radiation superposed on the soliton pulse propagated in single mode optical fiber
...Show More Authors

the first part of the research involves investigate the aspect of the radiation superposed on the one bright soliton pulse propagated on ideal single mode

View Publication Preview PDF
Publication Date
Wed May 17 2023
Journal Name
Journal Of Engineering
The Effect of Tool Path Strategy on Twist Behavior In Single Point Incremental Sheet Metal Forming
...Show More Authors

In Incremental sheet metal forming process, one important step is to produce tool path, an
accurate tool path is one of the main challenge of incremental sheet metal forming
process. Various factors should be considered prior to generation of the tool path i.e.
mechanical properties of sheet metal, the holding mechanism, tool speed, feed rate and
tool size. In this work investigation studies have been carried out to find the different tool
path strategies to control the twist effect in the final product manufactured by single point
incremental sheet metal forming (SPIF), an adaptive tool path strategy was proposed and
examined for several Aluminum conical models. The comparison of the proposed tool path with t

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Tue Jan 15 2013
Journal Name
Journal Of Kerbala University 11 (3)‏
Effect ofchemicalfertilizerand foliar spray ofgibberellicacidon mineral element andgibberellin-likesubstances content on someolivecultivars‏
...Show More Authors

Publication Date
Sat Mar 30 2013
Journal Name
Mathematical Problems In Engineering
CFD analysis of Heat transfer and friction factor characteristics in a circular tube fitted with Quadrant-cut twisted tape inserts
...Show More Authors

Publication Date
Mon Aug 05 2024
Journal Name
Pharmacia
A validated spectrophotometric analysis for simultaneous estimation of vincristine sulfate and bovine serum albumin in pure preparations using Vierordt’s method
...Show More Authors

The novel Vierordt’s approach, or simultaneous equation method, was created and validated for the concurrent determination of vincristine sulfate (VCS) and bovine serum albumin (BSA) in pure solutions utilizing UV spectrophotometry. It is simple, precise, economical, rapid, reliable, and accurate. This method depends on measuring absorbance at two wavelengths, 296 nm and 278 nm, which correspond to the λmax of VCS and BSA in deionized water, respectively. The calibration curves of VCS and BSA are linear at concentration ranges of 10–60 μg/mL and 200–1600 μg/mL, with correlation coefficient values (R2) of 1 and 0.999, respectively. The limits of detection (LOD) and quantification (LO

... Show More
View Publication
Scopus (2)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Mon Jun 22 2020
Journal Name
Baghdad Science Journal
Splitting the One-Dimensional Wave Equation. Part I: Solving by Finite-Difference Method and Separation Variables
...Show More Authors

In this study, an unknown force function dependent on the space in the wave equation is investigated. Numerically wave equation splitting in two parts, part one using the finite-difference method (FDM). Part two using separating variables method. This is the continuation and changing technique for solving inverse problem part in (1,2). Instead, the boundary element method (BEM) in (1,2), the finite-difference method (FDM) has applied. Boundary data are in the role of overdetermination data. The second part of the problem is inverse and ill-posed, since small errors in the extra boundary data cause errors in the force solution. Zeroth order of Tikhonov regularization, and several parameters of regularization are employed to decrease error

... Show More
View Publication Preview PDF
Scopus (4)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Sun Mar 30 2008
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
A Quantitative Analysis of the Mixing of Three Solids Different in Density by an Air Fluidized Bed
...Show More Authors

Three cohesionless free flowing materials of different density were mixed in an air fluidized bed to study the mixing process by calculating performance of mixing index according to Rose equation (1959) and to study the effect of four variables (air velocity, mixing time, particle size of trace component and concentration of trace component) on the mixing index and as well as on mixing performance. It was found that mixing index increases with increasing the air velocity, mixing time and concentration of trace component until the optimum value. Mixing index depends on the magnitude of difference in particle size The first set of experiments (salt then sand then cast iron) give higher mixing index and better performance of mixing than the

... Show More
View Publication Preview PDF
Publication Date
Thu Mar 29 2018
Journal Name
Construction Research Congress 2018
Consideration of Worker Safety in the Design Process: A Statistical-Based Approach Using Analysis of Variance (ANOVA)
...Show More Authors

View Publication
Scopus (2)
Crossref (3)
Scopus Crossref
Publication Date
Thu Jun 15 2017
Journal Name
Journal Of Baghdad College Of Dentistry
Mechanical evaluation of nano hydroxyapatite, chitosan and collagen composite coating compared with nano hydroxyapatite coating on commercially pure titanium dental implant
...Show More Authors

Background: Dental implants act as infrastructure for fixed restoration to look like as a natural tooth. Osseointegration is a biological events and considered as a base for success of dental implant. The aim of this study is to evaluate the bond strength between bone and Ti implant coated with mixture of nano hydroxyapatite-chitosan-collagen compared with Ti implants coated with nano hydroxyapatite implanted in rabbit tibia, after different period of implantation time (two and six weeks) by torque removal test. Material and methods: 36 screws of commercially pure titanium; 8mm in length and 3mm diameter , 18 screws coated with mixture of nano hydroxyapatite-chitosan-collagen and18 screws coated with nano hydroxyapatite by dip coating. St

... Show More
View Publication Preview PDF
Crossref (6)
Crossref