Preferred Language
Articles
/
huaVLZ4BmraWrQ4dbF97
Biomechanical finite element analysis of a single implant threaded in anterior and posterior regions of maxilla bone
...Show More Authors

Context: The ability of implant dentistry to be a successful alternative for edentulous patients has increased in the last decade. Clinical features such as osseointegration and stability, in addition to the endurance of the integration urged the researchers towards a better understanding of the design parameters that control long term success of the implants. It is therefore necessary to quantify the effect of changing implant design parameters on interface stress distribution within the maxilla bone. Methods and Materials: A 3D-finite element study was conducted to investigate the effect of changing implant shape parameters (implant body design and implant thread depth) on stress distribution while insertion of the implant in two different regions of maxilla bone (anterior (type III bone) and posterior (type IV bone)). A 3D-CAD geometry of implant-maxilla bone was created through importing digitally visualized CT skull images of a human adult, and then converted into a workable solid body through using a collection of engineering software. Tapered and cylindrical implant models with three different implant V-shaped thread depths (0.25 mm, 0.35 mm, 0.45 mm) were threaded into maxilla bone to investigate the design parameters effect on the final stress status. The proposed implant was of commercial dimensions of 10 mm length and 4 mm in diameter. A vertical static load of 250N was directly applied to the center of the suprastructure of the implant for each model. Results: Evaluations were performed for stress distribution patterns and maximum equivalent Von Mises (EQV) stresses for implants in two regions of maxilla bone under 250N vertical static loading. The obtained results throughout this work showed that, for all models, the highest stresses were located at the crestal cortical bone around the implant neck. The von-Mises stress distribution patterns at different models were similar and higher peak von-Mises stresses of cortical bone were seen in tapered implant body compared to cylinder body in all models. Conclusions: Within the restrictions of the current model, the results obtained can be applied clinically to select properly both implant thread depth and body shape design for a foreseeable success of implant therapy.

Scopus Crossref
View Publication
Publication Date
Wed Oct 20 2010
Journal Name
The International Journal Of Advanced Manufacturing Technology
Finite element modeling and simulation of proposed design magneto-rheological valve
...Show More Authors

Magneto-rheological (MR) valve is one of the devices generally used to control the speed of Hydraulic actuator of MR fluid. The performance of valve depends on the magnetic circuit design. Present study deals with a new design of MR valve. A mathematical model for the MR valve is developed and the simulation is carried out to evaluate the newly developed MR valve. The design of the magnetic circuit is accomplished by magnetic finite element software such as Finite Element Method Magnetic (FEMMR). The model dimensions of MR valve, material properties are taken into account. The results of analysis are presented in terms of magnetic strength H and magnetic flux density B. The simulation results based on the proposed model indicate that the ef

... Show More
View Publication
Scopus (37)
Crossref (30)
Scopus Clarivate Crossref
Publication Date
Sun Jun 01 2025
Journal Name
Results In Engineering
Structural Performance of Rail Connections: Experimental Testing and Finite Element Modeling
...Show More Authors

View Publication
Scopus (2)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Thu Mar 25 2021
Journal Name
Dental Materials Journal
Mechanical and thermal stress evaluation of PEEK prefabricated post with different head design in endodontically treated tooth: 3D-finite element analysis
...Show More Authors

View Publication
Scopus (29)
Crossref (28)
Scopus Clarivate Crossref
Publication Date
Fri Aug 11 2017
Journal Name
Journal Of Engineering
Thermo Elastic Analysis of Carbon Nanotube-Reinforced Composite Cylinder Utilizing Finite Element Method with the Theory of Elasticity
...Show More Authors

  

View Publication Preview PDF
Publication Date
Mon Feb 01 2021
Journal Name
Iop Conference Series: Materials Science And Engineering
Experimental and finite element analysis of mechanical behavior of concrete damaged by Alkali Aggregate Reaction (AAR) and repaired with CFRP Layers
...Show More Authors
Abstract<p>Concrete structures is affected by a deleterious reaction, which is known as Alkali Aggregate Reaction (AAR). AAR can be defined as a chemical reaction between the alkali content in the pore water solution of the cement paste and reactive forms of silica hold in the aggregate. This internal reaction produces expansion and cracking in concrete, which can lead to loss of strength and stiffness. Carbon fiber-reinforced polymer (CFRP) is one of the methods used to suppress further AAR expansion and rehabilitate and support damaged concrete structures. In this research, thirty-six cylindrical specimens were fabricated from non-reactive and reactive concrete, which contained fused silica as</p> ... Show More
View Publication
Crossref
Publication Date
Sun Mar 01 2020
Journal Name
Journal Of Engineering
Three-Dimensional Explicit Finite Element Simulation of Piled-Raft Foundation
...Show More Authors

This paper aims to validate a proposed finite element model to be adopted in predicting displacement and soil stresses of a piled-raft foundation. The proposed model adopts the solid element to simulate the raft, piles, and soil mass. An explicit integration scheme has been used to simulate nonlinear static aspects of the piled-raft foundation and to avoid the computational difficulties associated with the implicit finite element analysis.

The validation process is based on comparing the results of the proposed finite element model with those of a scaled-down experimental work achieved by other researchers. Centrifuge apparatus has been used in the experimental work to generate the required stresses to simulate t

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Mar 16 2021
Journal Name
2021 4th International Conference On Energy Conservation And Efficiency (icece)
Finite Element Modeling Of Finned Double-Pass Solar Air Heaters
...Show More Authors

View Publication
Scopus (4)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Tue Aug 22 2023
Journal Name
Advances In Structural Engineering
Experimental and finite element analysis of reinforced concrete multi-cell box girders retrofitted with carbon fiber reinforced polymer strips under torsion
...Show More Authors

This study expands the state of the art in studies that assess torsional retrofit of reinforced concrete (RC) multi-cell box girders with carbon fiber reinforced polymer (CFRP) strips. The torsional behavior of non-damaged and pre-damaged RC multi-cell box girder specimens externally retrofitted by CFRP strips was investigated through a series of laboratory experiments. It was found that retrofitting the pre-damaged specimens with CFRP strips increased the ultimate torsional capacity by more than 50% as compared to the un-damaged specimens subjected to equivalent retrofitting. This indicated that the retrofit has been less effective for the girder specimen that did not develop distortion beforehand as a result of pre-loading. From

... Show More
Scopus (12)
Crossref (10)
Scopus Clarivate Crossref
Publication Date
Tue Aug 22 2023
Journal Name
Advances In Structural Engineering
Experimental and finite element analysis of reinforced concrete multi-cell box girders retrofitted with carbon fiber reinforced polymer strips under torsion
...Show More Authors

This study expands the state of the art in studies that assess torsional retrofit of reinforced concrete (RC) multi-cell box girders with carbon fiber reinforced polymer (CFRP) strips. The torsional behavior of non-damaged and pre-damaged RC multi-cell box girder specimens externally retrofitted by CFRP strips was investigated through a series of laboratory experiments. It was found that retrofitting the pre-damaged specimens with CFRP strips increased the ultimate torsional capacity by more than 50% as compared to the un-damaged specimens subjected to equivalent retrofitting. This indicated that the retrofit has been less effective for the girder specimen that did not develop distortion beforehand as a result of pre-loading. From

... Show More
View Publication
Scopus (12)
Crossref (10)
Scopus Clarivate Crossref
Publication Date
Mon Jul 01 2019
Journal Name
Journal Of Craniofacial Surgery
Effect of Platelet-Rich Fibrin and Bone Morphogenetic Protein on Dental Implant Stability
...Show More Authors

Abstract: Recombinant human bone morphogenetic protein-2 (rhBMP-2) and platelet-rich fibrin (PRF) bioactive materials have been used to enhance healing and improve dental implant stability. This study aimed to compare the effect of rhBMP-2 and PRF bioactive materials on dental implant stability at different intervals and to evaluate the correlation of implant length and diameter with implant stability. Two bioactive materials were compared to evaluate their effect on dental implant stability. A total of 32 patients (102 dental implants) were divided into 3 groups: 24 dental implants with bone morphogenetic protein (BMP), 27 dental implants with PRF, and 51 dental implants without BMP or PRF (control group). Data were statistically analyzed

... Show More
View Publication
Scopus (17)
Crossref (21)
Scopus Clarivate Crossref