Preferred Language
Articles
/
huaVLZ4BmraWrQ4dbF97
Biomechanical finite element analysis of a single implant threaded in anterior and posterior regions of maxilla bone
...Show More Authors

Context: The ability of implant dentistry to be a successful alternative for edentulous patients has increased in the last decade. Clinical features such as osseointegration and stability, in addition to the endurance of the integration urged the researchers towards a better understanding of the design parameters that control long term success of the implants. It is therefore necessary to quantify the effect of changing implant design parameters on interface stress distribution within the maxilla bone. Methods and Materials: A 3D-finite element study was conducted to investigate the effect of changing implant shape parameters (implant body design and implant thread depth) on stress distribution while insertion of the implant in two different regions of maxilla bone (anterior (type III bone) and posterior (type IV bone)). A 3D-CAD geometry of implant-maxilla bone was created through importing digitally visualized CT skull images of a human adult, and then converted into a workable solid body through using a collection of engineering software. Tapered and cylindrical implant models with three different implant V-shaped thread depths (0.25 mm, 0.35 mm, 0.45 mm) were threaded into maxilla bone to investigate the design parameters effect on the final stress status. The proposed implant was of commercial dimensions of 10 mm length and 4 mm in diameter. A vertical static load of 250N was directly applied to the center of the suprastructure of the implant for each model. Results: Evaluations were performed for stress distribution patterns and maximum equivalent Von Mises (EQV) stresses for implants in two regions of maxilla bone under 250N vertical static loading. The obtained results throughout this work showed that, for all models, the highest stresses were located at the crestal cortical bone around the implant neck. The von-Mises stress distribution patterns at different models were similar and higher peak von-Mises stresses of cortical bone were seen in tapered implant body compared to cylinder body in all models. Conclusions: Within the restrictions of the current model, the results obtained can be applied clinically to select properly both implant thread depth and body shape design for a foreseeable success of implant therapy.

Scopus Crossref
View Publication
Publication Date
Sat Feb 01 2020
Journal Name
Iop Conference Series: Materials Science And Engineering
Behavior of passive single pipe pile in sandy soil
...Show More Authors
Abstract<p>This research focuses on studying the effects of soil movement on the behavior of an existing pile driven in sandy soil. A physical model has been manufactured to investigate the effect of construction of an embankment adjacent to free head single pile driven in sand of dry unit weight of 13.5 kN/m<sup>3</sup>. The model pile of diameter (D) of 10 mm are tested under two conditions of loading: loaded axially and without load. The model piles are instrumented with strain gauges along the embedded length to measure strains resulting from the soil movement. The embankment loads are applied at distances of 2.5, 5, and 10D from the edge of the pile. The results obtained from the </p> ... Show More
View Publication Preview PDF
Scopus (5)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Thu Sep 06 2018
Journal Name
Al-khwarizmi Engineering Journal
Bone Defect Animal Model for Hybrid Polymer Matrix Nano Composite as Bone Substitute Biomaterials
...Show More Authors

Addition of bioactive materials such as Titanium oxide (TiO2), and incorporation of bio inert ceramic such as alumina (Al2O3), into polyetheretherketone (PEEK) has been adopted as an effective approach to improve bone-implant interfaces. In this paper, hot pressing technique has been adopted as a production method. This technique gave a homogenous distribution of the additive materials in the proposed composite biomaterial. Different compositions and compounding temperatures have been applied to all samples. Mechanical properties and animal model have been studied in all different production conditions. The results of these new TiO2/Al2O3/PEEK biocomposites with different

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Journal Of The Mechanical Behavior Of Materials
Molding and simulation sedimentation process using finite difference method
...Show More Authors
Abstract<p>The goal of this research is to develop a numerical model that can be used to simulate the sedimentation process under two scenarios: first, the flocculation unit is on duty, and second, the flocculation unit is out of commission. The general equation of flow and sediment transport were solved using the finite difference method, then coded using Matlab software. The result of this study was: the difference in removal efficiency between the coded model and operational model for each particle size dataset was very close, with a difference value of +3.01%, indicating that the model can be used to predict the removal efficiency of a rectangular sedimentation basin. The study also revealed</p> ... Show More
Publication Date
Wed Apr 01 2026
Journal Name
Journal Of The Faculty Of Medicine Baghdad
Sequencing of Catalytic Serine Protease, Linker, and Activation Peptide Domains-Coding Regions of the F9 Gene in Iraqi Hemophilia B Patients
...Show More Authors

Background: Hemophilia B is an X-linked recessive disorder caused by mutations in the F9 gene, causing bleeding tendency predominantly in males. The mutational spectrum of the F9 gene has not been adequately studied in Iraq. Objectives: To detect the disease-causing variants of exons 6, 7, and 8 and immediate introns of F9 gene using Sanger sequencing among Iraqi hemophilia B patients and to correlate them with phenotypes. Methods: Forty Iraqi hemophilia B patients were recruited for this cross-sectional study from The Hereditary Bleeding Disorder Ward in the Children Welfare Teaching Hospital, Medical City, Baghdad, between November 2021 and April 2022 using a consecutive sampling technique. Peripheral blood samples were used for sequencin

... Show More
View Publication
Scopus Crossref
Publication Date
Thu Nov 09 2023
Journal Name
Biomedicine
Role of immunological and biochemical markers in bone turnover in type I diabetic patients in Karbala province, Iraq
...Show More Authors

Introduction & Aim: Long-term diabetes mellitus (DM) is known to have a deleterious impact on bone health, resulting in change in bone mineral density, bone turnover, and bone quality, all of which increase the risk of fractures. The aim of. this study was to link immunological and pro-inflammatory cytokine (I.L-6, I.L-1, and TNF-alpha) markers in patients.with type 1 diabetes to Their connection to bones formation (sPINP) and bone resorption parameters (sCTX).   Materials & Methods: This study included 80 patients suffering from T1DM in the age range of 20-45 years. The patients were assayed for their biochemical (Vitamin D and HbA1c), Immunological (IL-6, IL-1 and TNF-alpha) parameters, as well as bone formation and resor

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Sun Nov 20 2022
Journal Name
Journal Of New Zealand Studies
The Impacts of Environmental-Geomorphology of the Kut Barrage on the Tigris Waterway and the Neighboring regions
...Show More Authors

The research dealt with the effect of Kut Barrage on the geomorphological processes and the natural environment system in the course of the Tigris between the cities of Al-Ahrar and Kut in central Iraq. It was clear from the research the contribution of Kut Barrage in changing the surface runoff system between the front and back of the barrage, as well as changing the type of processes and the prevailing geomorphic forms, as the sedimentation activates the front of the barrage and erosion at its back, which affected the change in the morphology of the river, sediment retention at the front of the barrage, the burial of the bottom and reducing the validity of the stream. This also affects the efficiency of the barrage’s work and coastal er

... Show More
Publication Date
Wed Dec 24 2025
Journal Name
Baghdad Science Journal
Comparison of XRF and ICP-OES Methods to Determine Trace Element Concentrations of Kidney Stones in Iraqi Patients
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Fri Mar 01 2024
Journal Name
Baghdad Science Journal
A Comparison between Ericson's Formulae Results and Experimental Data Using New Formulae of Single Particle Level Density
...Show More Authors

The partial level density PLD of pre-equilibrium reactions that are described by Ericson’s formula has been studied using different formulae of single particle level density . The parameter  was used from the equidistant spacing model (ESM) model and the non- equidistant spacing model (non-ESM) and another formula of  are derived from the relation between  and level density parameter . The formulae used to derive  are the Roher formula, Egidy formula, Yukawa formula, and Thomas –Fermi formula. The partial level density results that depend on  from the Thomas-Fermi formula show a good agreement with the experimental data.

View Publication Preview PDF
Scopus Crossref
Publication Date
Thu Jan 07 2016
Journal Name
Ibn Al-haitham Jour. For Pure & Appl. Sci.
Determination of Some Trace Element Levels in Iraqi Male patients with Colorectal Cancer
...Show More Authors

Alterations of trace element concentrations adversely affect biological processes and could promote carcinogenesis. Trace element deficiency or excess is implicated in the development or progression of some cancers like colorectal cancer. The aim of the present study was to compare the serum copper (Cu) and zinc (Zn) concentrations in patients with colorectal cancer from Iraqi male patient with those of healthy subjects. During the period of March 2015 until august 2015, a total of 25 patients with metastatic colon cancer and 20 healthy volunteers were enrolled from the Al-Kadhimia Teaching Hospital after the diagnosis using a histopathological examination for the malignant tumor; their age was between (38-60) years. Higher levels o

... Show More
Publication Date
Tue Jul 21 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Hard palate bone density and thickness determination using CT scan and their relationships with body compositions measured by bioelectrical impedance analysis for Iraqi adult sample
...Show More Authors

Background: This study was conducted to evaluate the hard palate bone density and thickness during 3rd and 4th decades and their relationships with body mass index (BMI) and compositions, to allow more accurate mini-implant placement. Materials and method: Computed tomographic (CT) images were obtained for 60 patients (30 males and 30 females) with age range 20-39 years. The hard palate bone density and thickness were measured at 20 sites at the intersection of five anterioposterior and four mediolateral reference lines with 6 and 3 mm intervals from incisive foramen and mid-palatal suture respectively. Diagnostic scale operates according to the bioelectric impedance analysis principle was used to measure body weight; percentages of body fa

... Show More
View Publication Preview PDF