Context: The ability of implant dentistry to be a successful alternative for edentulous patients has increased in the last decade. Clinical features such as osseointegration and stability, in addition to the endurance of the integration urged the researchers towards a better understanding of the design parameters that control long term success of the implants. It is therefore necessary to quantify the effect of changing implant design parameters on interface stress distribution within the maxilla bone. Methods and Materials: A 3D-finite element study was conducted to investigate the effect of changing implant shape parameters (implant body design and implant thread depth) on stress distribution while insertion of the implant in two different regions of maxilla bone (anterior (type III bone) and posterior (type IV bone)). A 3D-CAD geometry of implant-maxilla bone was created through importing digitally visualized CT skull images of a human adult, and then converted into a workable solid body through using a collection of engineering software. Tapered and cylindrical implant models with three different implant V-shaped thread depths (0.25 mm, 0.35 mm, 0.45 mm) were threaded into maxilla bone to investigate the design parameters effect on the final stress status. The proposed implant was of commercial dimensions of 10 mm length and 4 mm in diameter. A vertical static load of 250N was directly applied to the center of the suprastructure of the implant for each model. Results: Evaluations were performed for stress distribution patterns and maximum equivalent Von Mises (EQV) stresses for implants in two regions of maxilla bone under 250N vertical static loading. The obtained results throughout this work showed that, for all models, the highest stresses were located at the crestal cortical bone around the implant neck. The von-Mises stress distribution patterns at different models were similar and higher peak von-Mises stresses of cortical bone were seen in tapered implant body compared to cylinder body in all models. Conclusions: Within the restrictions of the current model, the results obtained can be applied clinically to select properly both implant thread depth and body shape design for a foreseeable success of implant therapy.
Throughout this paper, a generic iteration algorithm for a finite family of total asymptotically quasi-nonexpansive maps in uniformly convex Banach space is suggested. As well as weak / strong convergence theorems of this algorithm to a common fixed point are established. Finally, illustrative numerical example by using Matlab is presented.
Background: Studies discussing the correlation between biochemical markers of bone turnover and the diagnosis of osteoporosis in postmenopausal Iraqi women are rare. This study is devoted to find out the significance of serum osteocalcin (OC) and osteopontin (OPN) levels with the incidence of osteoporosis and its major complication (fracture).Objectives: to investigate the significance of bone turnover biochemical markers; serum osteocalcin and serum osteopontin in evaluating osteoporosis for postmenopausal Iraqi women with and without history of vertebral fracture, as well as to explore the relationship of these markers with bone mineral density (BMD).Methods: Fifty seven postmenopausal women whose ages are fifty years old and over, cat
... Show MoreIn this work, a single pile is physically modeled and embedded in an upper liquefiable loose sand layer overlying a non-liquefiable dense layer. A laminar soil container is adopted to simulate the coupled static-dynamic loading pile response during earthquake motions: Ali Algharbi, Halabjah, El-Centro, and Kobe earthquakes. During seismic events with combined loading, the rotation along the pile, the lateral and vertical displacements at the pile head as well as the pore pressure ratio in loose sandy soil were assessed. According to the experimental findings, combined loading that ranged from 50 to 100% of axial load would alter the pile reaction by reducing the pile head peak ground acceleration, rotation of the pile, and lateral displacem
... Show MoreBackground: Anterior disc displacement with reduction (ADDWR) is the most common form of the internal derangement (ID) of temporomandibular joint (TMJ). It is a painful progressive dysfunction and clinically characterized by reciprocal clicking due to shift in the disc anteriorly in relation to the condyle and fossa during mandible elevation. Minimally invasive therapy such as intra-articular injection of platelet-rich plasma (PRP) has been used. PRP is a natural autologous product with a high platelet concentration obtained by centrifugation process to enhance tissue healing through several growth factors (GFs), which are released after endogenous activation. The aim of this study is to assess this technique which is increasingly used toda
... Show MoreThe rubber ropes exercises affected muscle groups, which in turn affects the corners of the conditions of the body before and over the barrier where affected the time passed. To change the angle of the approaching and payment impact on passing each times the barrier 1-5. That passed over the barrier 1and gate 5 impacts on the nature of the achievement, where time has become less. Find the values of cruise missiles and other phases and stages of pitch angle other categories which it enshrines stood as compelling rejection men's 110m hurdles. Find the value of the instant messaging distances between different barriers and stages. Studies by adding rubber sling barriers race categories, measurement of kinematic variables. Emphasis on the devel
... Show MoreBackground: Even the wide use of dental implants, still there is a proportion of implants are failed due to infection. Much considerable attention has been paid to modify the implant surface. Coating of dental implant with a biocomposite material of suitable properties can improve osseointegration. And this is the main concern of this study. The aim of present study was to evaluate the use of a biocomposite coating of dental implant with (ceramic nano Al2O3 and metalic AgNo3) on the bond strength at bone – implant interface and tissue reaction. Materials and methods: A total number of forty-eight screws, CpTi dental implant used in this study. Half of these screws were coated with a biocomposite material of nano (Al2O3and AgNo3), thi
... Show MoreCurcumin is a yellow pigment produced from the rhizomes of the Curcuma longa plant and a primary chemo preventive component of turmeric is used as a spice and food coloring ingredient. Curcumin has a large number of pharmacological activities, such as anticancer, anti-diabetic, antioxidant, anti-infectious, and anti-inflammatory properties.Investigation of the geno-protective effect of curcumin on methotrexate induces chromosomal aberrations of spleen and bone marrow cells. In this study, 32 mice were used and divided into four groups (eight mice at each group) as follows: Group1 (negative control): Dimethyl sulfoxide was given intraperitoneally to mice every day for ten days.Group2 (positive control): Mice were received a single do
... Show More