Context: The ability of implant dentistry to be a successful alternative for edentulous patients has increased in the last decade. Clinical features such as osseointegration and stability, in addition to the endurance of the integration urged the researchers towards a better understanding of the design parameters that control long term success of the implants. It is therefore necessary to quantify the effect of changing implant design parameters on interface stress distribution within the maxilla bone. Methods and Materials: A 3D-finite element study was conducted to investigate the effect of changing implant shape parameters (implant body design and implant thread depth) on stress distribution while insertion of the implant in two different regions of maxilla bone (anterior (type III bone) and posterior (type IV bone)). A 3D-CAD geometry of implant-maxilla bone was created through importing digitally visualized CT skull images of a human adult, and then converted into a workable solid body through using a collection of engineering software. Tapered and cylindrical implant models with three different implant V-shaped thread depths (0.25 mm, 0.35 mm, 0.45 mm) were threaded into maxilla bone to investigate the design parameters effect on the final stress status. The proposed implant was of commercial dimensions of 10 mm length and 4 mm in diameter. A vertical static load of 250N was directly applied to the center of the suprastructure of the implant for each model. Results: Evaluations were performed for stress distribution patterns and maximum equivalent Von Mises (EQV) stresses for implants in two regions of maxilla bone under 250N vertical static loading. The obtained results throughout this work showed that, for all models, the highest stresses were located at the crestal cortical bone around the implant neck. The von-Mises stress distribution patterns at different models were similar and higher peak von-Mises stresses of cortical bone were seen in tapered implant body compared to cylinder body in all models. Conclusions: Within the restrictions of the current model, the results obtained can be applied clinically to select properly both implant thread depth and body shape design for a foreseeable success of implant therapy.
Background: In the traditional protocol, the patient should wait after extraction up to six months to place the dental implant in healed bone, this waiting time accompanied by varying degrees of alveolar bone changes. In order to overcome these problems, immediate implant placement in the fresh extraction socket was introduced. The Aim of this study was to evaluate the outcome of the immediate implant placement utilizing Resonance Frequency Analysis (RFA) to quantify implant stability and osseointegration. Materials and Methods: A total of (23) patients participated in the study, receiving (44) implants placed in the sockets of teeth indicated for extraction. Clinical and radiographic preoperative assessment was accomplished for each patie
... Show MoreThis study aimed to manufacture an innovative device that enables the player to walk after the operation and improves the functional efficiency through the improvement in the range of motion as well as the improvement in the size of the muscles working on the knee joint. The research, the study population consisted of players with severing the anterior cruciate ligament of the advanced soccer players, and the number of the research sample was (5) injured for the control sample and (5) for the experimental sample in Abu Ghraib Hospital and some rehabilitation centers for a period of six months, and the pre-tests were conducted after two weeks of The cruciate ligament surgery was performed, and the innovative device was used for the e
... Show MoreBackground: There are so many evidences that there was antimicrobial resistance, and there were many strains that emerged which were difficult to treat. We are living in a situation that the dissemination of multiple drug resistant bacteria can lead us to the situation, in which no treatment could be offered for bacterial infection in future.
Aim of study: Assessment of nurses’ knowledge, attitude, and practices on antibiotic use and resistance in Fatima Al Zahra hospital in Baghdad.
Subjects and Methods: A cross-sectional study. The study was carried on from 1st of February to 31st of March 2021. A questionnaire was constructed by the research team based on literature review and was adapted to asses
... Show MoreIn this ˑwork, we present theˑ notion of the ˑgraph for a KU-semigroup as theˑundirected simple graphˑ with the vertices are the elementsˑ of and weˑˑstudy the ˑgraph ofˑ equivalence classesˑofˑ which is determinedˑ by theˑ definition equivalenceˑ relation ofˑ these verticesˑ, andˑ then some related ˑproperties areˑ given. Several examples are presented and some theorems are proved. Byˑ usingˑ the definitionˑ ofˑ isomorphicˑ graph, ˑwe showˑ thatˑ the graphˑ of equivalence ˑclasses ˑand the ˑgraphˑof ˑa KU-semigroup ˑ areˑ theˑ sameˑ, in special cases.
Steady conjugate natural convection heat transfers in a two-dimensional enclosure filled with fluid saturated porous medium is studied numerically. The two vertical boundaries of the enclosure are kept isothermally at same temperature, the horizontal upper wall is adiabatic, and the horizontal lower wall is partially heated. The Darcy extended Brinkman Forcheimer model is used as the momentum equation and Ansys Fluent software is utilized to solve the governing equations. Rayleigh number (1.38 ≤ Ra ≤ 2.32), Darcy number (3.9 * 10-8), the ratio of conjugate wall thickness to its height (0.025 ≤ W ≤ 0.1), heater length to the bottom wall ratio (1/4 ≤ ≤ 3/4) and inclination angle (0°, 30° and 60°) are the main consid
... Show MoreBackground: Opportunistic viral infections make an important threat to renal transplantation recipients (RTRs), and with the use of more intense newly-developed immunosuppressive drugs; the risk of renal allograft loss due to reactivation of these viruses has increased considerably. At the top priority of these viruses lie BK polyomavirus (BKV) and human cytomegalovirus (CMV). Reactivation of these viruses in these chronically immunosuppressed RTRs can lead to renal impairment and subsequently allograft loss, unless early detected and properly treated. Objectives: The study aimed to detect and quantify plasma viral load of BKV and CMV in RTRs using quantitative real time PCR (qRT-PCR), in order to study the prevalence of these two viruses i
... Show MorePurpose: To compare the central corneal thickness (CCT),minimum corneal thickness (MCT) and corneal power measured using theScheimpflug-Placido device and optical coherence tomography (OCT) in healthy eyes. Study Design: Descriptive observational. Place and Duration of Study: Al-Kindy college of medicine/university of Baghdad, from June 2021 to April 2022. Methods: A total of 200 eyes of 200 individuals were enrolled in this study. CCT and MCT measurements were carried out using spectral-domain optical coherence tomography (Optovue) and a Scheimpflug-Placido topographer (Sirius).The agreement between the two approaches was assessed using Bland-Altman analysis in this study. Results: Mean age was 28.54 ± 6.6 years, me
... Show MoreSolid state blue laser source is a solid state laser include generation of IR laser light 1064 nm and companied with other wavelength 810 nm that invented from other active medium (Tm:ZBLAN) and non-linear crystal (CLBO) are used to generate fourth harmonic of the resultant wavelength 1874 nm that is blue laser light of 460nm. Several optical component have been designed by multilayer dielectric structure and anti reflection coating analysis. By using MATLAB soft ware, the simulation done and used the following non linear material (ZrO2, HfO2, MgO, SiO, Ta2O5 CaF2) and other linear material (ZnO, MgF2, GaAs, AlAs, BaF2, LiF, TiO2) as coating material. The result showed that as more quarter wave layers are added to the structure, the refl
... Show More