Preferred Language
Articles
/
hhYUTocBVTCNdQwCB0NU
Evaluation of the Serum Level of Interleukin-6 in Patients Undergoing Surgical Removal of Impacted Mandibular Third Molars
...Show More Authors

Evaluation of the Serum Level of Interleukin-6 in Patients Undergoing Surgical Removal of Impacted Mandibular Third Molars, Hussain A Taher*, Salwan Y Bede

View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Dec 01 2010
Journal Name
Desalination And Water Treatment
Removal of lead, cadmium, and mercury ions using biosorption
...Show More Authors

View Publication
Scopus (31)
Crossref (21)
Scopus Clarivate Crossref
Publication Date
Wed Sep 30 2020
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Removal of Tetracycline from Wastewater Using Circulating Fluidized Bed
...Show More Authors

   In this study, the circulating fluidized bed was used to remove the Tetracycline from wastewater utilizing a pistachio shell coated with ZnO nanoparticles. Several parameters including, Tetracycline solution flowrate, initial static bed height, Tetracycline initial concentration and airflow rate were systematically examined to show their effect on the breakthrough curve and the required time to reach the adsorption capacity and thus draw the fully saturated curve of the adsorbent. Results showed that using ZnO nanoparticles will increase the adsorbent surface area and pores and as a result the adsorption increased, also the required time for adsorbent saturation increased and thus the removal efficiency may be achieved at mi

... Show More
View Publication Preview PDF
Crossref (21)
Crossref
Publication Date
Tue Mar 01 2022
Journal Name
Journal Of Engineering
Removal of Dye from Synthetic Wastewater by Liquid Membrane
...Show More Authors

New technologies have risen into popularity causing the Liquid membrane techniques to evolve over other separation techniques due to its high selectivity and recovery, increased fluxes, and reduced investment and operating cost. This work focuses on extracting Methylene Blue (MB), a cationic dye using a simple BLM separation technique from its aqueous phase. It combines extraction and stripping in a single unit operation. The feed phase was an aqueous solution of MB, the solvent chosen was soybean oil for the liquid/organic membrane phase, and tri-octyl amine acted as a carrier. The strip phase was a hydrochloric acid solution for this study. A two-phase equilibrium study was done to choose the correct solvent, carrier,

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Tue Sep 01 2009
Journal Name
Al-khwarizmi Engineering Journal
Removal of Sulfate from Waste Water by Activated Carbon
...Show More Authors

Activated carbon was Produced from coconut shell and was used for removing sulfate from industrial waste water in batch Processes. The influence of various parameter were studied such as pH (4.5 – 9.) , agitation time (0 – 120)min and adsorbent dose (2 – 10) gm.

The Langmuir and frandlich adsorption capacity models were been investigated where showed there are fitting with langmmuir model with squre regression value ( 0.76). The percent of removal of  sulfate (22% - 38%) at (PH=7) in the isotherm experiment increased  with adsorbent mass increasing. The maximum removal value of sulfate at  different pH experiments is (43%) at pH=7.

View Publication Preview PDF
Publication Date
Sun Jun 30 2002
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Removal of Sulfur Dioxide from Sulfuric Acid Plant Emissions
...Show More Authors

View Publication Preview PDF
Publication Date
Wed Dec 25 2019
Journal Name
Journal Of Engineering
Removal of Cadmium from Industrial Wastewater using Electrocoagulation Process
...Show More Authors

Cadmium is one of the heavy metal found in the wastewater of many industries. The electrocoagulation offers many advantages for the removal of cadmium over other methods. So the removal of cadmium from wastewater by using electrocoagulation was studied to investigate the effect of operating parameters on the removal efficiency. The studied parameters were the initial pH, initial concentration, and applied voltage. The study experiments were conducted in a batch reactor with  with two pairs of aluminum electrodes with dimension  and 2mm in thick with 1.5 cm space between them. The optimum removal was obtained at pH =7, initial concentration = 50 mg/L, and applied voltage = 20 V and it was 90%.

View Publication Preview PDF
Crossref (10)
Crossref
Publication Date
Sat May 01 2021
Journal Name
Journal Of Physics: Conference Series
Evaluation the reactions of production the radioactive Iodine-124
...Show More Authors

Nowadays, the field of radionuclide treatment is enjoying an exciting stage and preparing for further growth and progress in the future. For instance, in Asia, the large spread of liver and thyroid diseases has resulted in several new developments/clinical trials using molecular radiotherapy (i.e. targeted radionuclide therapy). Iodine-124 has unique physical properties including long half-life that adding an advantage for pharmacokinetics and radiopharmaceutical analysis. One of its applications in nuclear medicine is in Positron Emission Tomography (PET).

View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Mon Feb 23 2026
Journal Name
Journal Of Baghdad College Of Dentistry
The Effect of Acidity Level on Ions Released and Corrosion of Metal Orthodontic Appliances at Different Time Intervals (An In vitro Study)
...Show More Authors

ABSTRACT Background: This study measured the effects of three parameters pH value, length of immersion and type of archwire on metal ions released from orthodontic appliances. Materials and Methods: Ninety maxillary halves simulated fixed orthodontic appliances that were immersed in artificial saliva of different pH values (6.75, 5 and 3.5) during 28 day period. Three types of archwires were used: stainless steel, nickel titanium and thermal activated nickel titanium. The quantity of nickel and chromium ions was determined with the use of atomic force spectrophotometer while iron ions by spectrophotometer. Each orthodontic set was weighted two times, before the ligation and immersion in the artificial saliva and after 28 days at the end of

... Show More
View Publication Preview PDF
Publication Date
Mon Aug 01 2022
Journal Name
Azerbaijan Medical Journal
Molecular Co- Localization of Human Papilloma Virus 6 / 11 in Combined Resected Tissues from Nononcologic Palatine and Pharyngeal Tonsillar Hypertrophies
...Show More Authors

More than 450 distinct types of human papilloma virus recognized via recent molecular techniques. The low and high oncogenic risk-HPV genotypes have an association with a variety of benign and malignant tumors in the oropharyngeal and nasopharyngeal localizations. This study aimed to determine the rate of DNA detection of HPV genotype 6/11 in non-oncologic nasopharyngeal and palatine tonsillar tissues from pediatric patients subjected to adeno-tonsillectomies. A total number of 64 tissue specimens enrolled; 44 non-oncologic nasopharyngeal and palatine hypertrophied tissue specimens from 22 pediatric patients sustained combined adeno-tonsillectomies and compared to 20 nasal trimmed tissues with unremarkable pathological changes (in

... Show More
Publication Date
Mon Dec 18 2017
Journal Name
Al-khwarizmi Engineering Journal
Prediction of Surface Roughness and Material Removal Rate in Electrochemical Machining Using Taguchi Method
...Show More Authors

Electrochemical machining is one of the widely used non-conventional machining processes to machine complex and difficult shapes for electrically conducting materials, such as super alloys, Ti-alloys, alloy steel, tool steel and stainless steel.  Use of optimal ECM process conditions can significantly reduce the ECM operating, tooling, and maintenance cost and can produce components with higher accuracy. This paper studies the effect of process parameters on surface roughness (Ra) and material removal rate (MRR), and the optimization of process conditions in ECM. Experiments were conducted based on Taguchi’s L9 orthogonal array (OA) with three process parameters viz. current, electrolyte concentration, and inter-electrode gap. Sig

... Show More
View Publication Preview PDF
Crossref (5)
Crossref