Preferred Language
Articles
/
heYQaJwBmraWrQ4dhUm4
Thermo‐Enviro‐Economic Study of Solar Concentrated Hexagonal Covered Tubular Still Using Interrupted and Tilted Receiver
...Show More Authors
ABSTRACT<p>Solar energy is still commonly used to produce clean drinking water due to its simple construction, low maintenance, and ecofriendliness. This work aims to experimentally investigate the yield upgrade and the thermal performance of a novel concentrated single‐axis tracking trough tubular solar still (TSS). This tubular still is identified by three baffles that generate four interrupted sections in the U‐receiver, which is inserted with copper mesh and fitted in a hexagonal‐shaped glass cover. Two identical TSS models were side‐by‐side outdoor tested in Baghdad‐Iraq 33.3° N and 43.3° E from January to March 2024. The first is inserted with black copper mesh (Model I), and the other has no insertion (Model ll). The effect of the inserted copper mesh (60, 120, and 180 g) and the receivers' tilt angle (5°, 10°, and 15°) on the still performance are involved. The still thermal performance is analyzed per heat transfer coefficients, energy, and exergy efficiencies. The results revealed that the accumulated daily yield is enhanced for Model I by 78.9%–194.8% while the thermal efficiency is enhanced by 68.3%–206.4% when it is tilted at 15° with the insertion of 60–180 g copper mesh, respectively, compared with Model II. It is concluded that an effective improvement in the solar still yield is obtained by using copper mesh.</p>
Scopus Crossref
View Publication
Publication Date
Sat May 30 2020
Journal Name
Neuroquantology
Comparative Study for Optoelectronic Properties of Zn (Te, Se) Solar Cells
...Show More Authors

View Publication
Scopus (16)
Crossref (14)
Scopus Crossref
Publication Date
Sat Mar 01 2014
Journal Name
Renewable Energy
Field study of various air based photovoltaic/thermal hybrid solar collectors
...Show More Authors

In the present work a comparative study for thermal and electrical performance of different hybrid photovoltaic/thermal collectors designs for Iraq climate conditions have been carried out. Four different types of air based hybrid PV/T collectors have been manufactured and tested. Three collectors consist of four main parts namely, channel duct, glass cover, axial fan to circulate air and two PV panels in parallel connection. The measured parameters are, the temperature of the upper and the lower surfaces of the PV panels, air temperature along the collector, air flow rate, pressure drop, power produced by solar cell, and climate conditions such as wind speed, solar radiation and ambient temperature. The thermal and hydraulic performances o

... Show More
View Publication
Scopus (126)
Crossref (114)
Scopus Crossref
Publication Date
Mon May 18 2026
Journal Name
Scientific Reports
Fluorescein spectrofluorometric quenching detection of chloride and iodide using eight-Blue-LEDs excitation and dual solar cells
...Show More Authors
Abstract<p>This study presents a novel, custom‑built fluorescence detector for the precise determination of chloride and iodide ions based on their quenching effect on fluorescein. The detection system incorporates eight blue LEDs irradiation sources arranged at 0–90° angles relative to twin solar cell detectors connected. Two fluorescence quenching strategies were developed. The injected‑mixture mode (IMFQ) exhibited linear ranges of 0.00–1.00 mM for Cl⁻ and 0.00–1.25 mM for I⁻, with detection limits of 20 µM and 10 µmol L⁻¹, respectively. The continuous‑flow mode (CFFQ) demonstrated superior sensitivity with a dispersion factor of 1.33, wider linear ranges (0.1–6.0 m</p> ... Show More
View Publication
Scopus Crossref
Publication Date
Fri Mar 01 2019
Journal Name
Al-khwarizmi Engineering Journal
Hard Chromium Electroplating and Improvement the Properties by the Thermo Chemical Treatments (Solid Carburizing) of Low Carbon Steel
...Show More Authors

In this research the hard chromium electroplating process, which is one of the common methods of overlay coating was used, by using chromium acid as source of chromium and sulphuric acid as catalyst since the ratio between chromic acid and sulphuric acid is (100 : 1) consequently. Plating process was made by applying current of density (40 Amp / dm2) and the range of solution temperature was (50 – 55oC) with different time periods (1-5 hr). A  low carbon steel type (Ck15) was used as substrate for hard chromium electroplating. Solid carburization was carried out for hard chromium plating specimen at temperature (925oC) with time duration (2 hr) to be followed with quenching and tempering

... Show More
View Publication Preview PDF
Publication Date
Mon Jun 19 2023
Journal Name
Journal Of Engineering
Manufacturing and Study the performance of Selective Surfaces that used in flat plate Solar Collectors
...Show More Authors

In this research an experimental study has done for testing the thermal performance of selective surfaces used in solar collectors for substrate of iron, galvanized iron and aluminum which are commercially available. The coating process for the samples has done in two ways, the electroplating and the chemical spray pyrolysis. The results of the thermal performance test of these samples are comparing with the thermal performance of a sample without paint and other paint with black paint without shines commercially available. For the electroplated samples, the performance study has done for different immersion time in plating bath, the
distance between electrical poles, the current density, and area ratio of the sample plated area to

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Dec 01 2018
Journal Name
Al-khwarizmi Engineering Journal
Enhancement of Hybrid Solar Air Conditioning System using a New Control Strategy
...Show More Authors

Enhancement of the performance for hybrid solar air conditioning system was presented in this paper. The refrigerant temperature leaving the condenser was controlled using three-way valve, this valve was installed after the compressor to regulate refrigerant flow rate towards the solar system. A control system using data logger, sensors and computer was proposed to set the opening valve ratio. The function of control program using LabVIEW software is to obtain a minimum refrigerant temperature from the condenser outlet to enhance the overall COP of the unit by increasing the degree of subcooled refrigerant. A variable load electrical heater with coiled pipe was used instead of the solar collector and the storage tank to simulate the sola

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Dec 01 2015
Journal Name
Solar Energy
A review of studies on using nanofluids in flat-plate solar collectors
...Show More Authors

Continuous escalation of the cost of generating energy is preceded by the fact of scary depletion of the energy reserve of the fossil fuels and pollution of the environment as developed and developing countries burn these fuels. To meet the challenge of the impending energy crisis, renewable energy has been growing rapidly in the last decade. Among the renewable energy sources, solar energy is the most extensively available energy, has the least effect on the environment, and is very efficient in terms of energy conversion. Thus, solar energy has become one of the preferred sources of renewable energy. Flat-plate solar collectors are one of the extensively-used and well-known types of solar collectors. However, the effectiveness of the coll

... Show More
Scopus (137)
Crossref (131)
Scopus Clarivate Crossref
Publication Date
Wed Apr 01 2020
Journal Name
Journal Of Economics And Administrative Sciences
German economic will
...Show More Authors

The economic renaissance of Germany began in the mid-nineteenth century, specifically in the year 1848, with the emergence of industry in the east of the country and the creation of a railroad linking the east of the country with its west, and the state and industrial investors at that time adopting a savings approach at the expense of consumption, and thus the emergence of surplus savings and capital accumulation (the basis of economic growth). This helped the German industry to recover locally to cover the need of the local market without resorting to importing, that is, self-reliance in providing life requirements.

    And the Germans continued this approach, especially for capitali

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Oct 01 2015
Journal Name
Journal Of Engineering
Study of Energy Gains by Orientation of Solar Collectors in Baghdad City
...Show More Authors

Firstly, in this study, a brief updated description and applications of different solar collectors used in renewable energy systems for supplying electric and thermal energy was presented. Secondly, an attempt was made to utilize tilting orientation of solar collector for maximizing collector energy with time in respect to horizontal orientation. For energy calculation, global solar radiation was used since they are directly related.  For that purpose, field measurements of half-hourly radiation on two flat panels of tilting and horizontal orientations were carried out throughout 8-month period under local climate of Baghdad. Then, energy gain and radiation level averages were calculated based on the field radiation

... Show More
View Publication Preview PDF
Publication Date
Sun Jun 18 2017
Journal Name
Iraqi Journal Of Agricultural Sciences
ECONOMIC STUDY TO MEASURE THE EFFICIENCY AND ITEMS OF MARKETING MARGINS OF TOMATO CROP YEAR 2015 AL-TAJI DISTRICT
...Show More Authors

The aim of this study is to calculate the marketing efficiency to measures range of efficiency of the marketing processes of crop and their satisfaction of consumer demand, and calculate the marketing margin in marketing process  for stage producer – whole sale and whole sale- retailer stage, and to fulfillment the requirements the research it is aims . The data was collected from 32 farms of tomato from AL-Taji District_Baghdad province Agricultural season 2015 non covered agriculture. The marketing efficiency of sample low 32. 5, and the  absolute marketing margin in stage of wholesaler-retailer was 230 I.d/kg, and retailers importance it was 39.36%, although that relative importance of the retailer profits from the marketing

... Show More
View Publication
Crossref (1)
Crossref