Pectin is available in many plants and in this study, the peels of tomatoes and beet were used to be an economical source of pectin production instead of dumping it with waste or using it as animal feed. The pectin extracted from the peels using different solutions, namely citric acid (2 M), oxalic acid (2%) and hydrochloric acid (0.5 M) the outcome of the extraction methods, 7. 1%, 6% and 11% respectively for tomatoes peels, while the pectin of beet peels were 8%, 6.5%, and 8.3%, and the highest percentage obtained in the manner of hydrochloric acid adopted in the manufacture of yogurt.Yogurt was manufactured with four treatments, in the first treatment standard pectin was added and the second treatment in addition to the pectin extracted from the peels of the tomatoes and the third treatment in addition to the peels of the beet and the treatment forth without adding any pectin. The samples were incubated with 42°C for 5 hours and the flavor grades were 9.2, 7.4, 7.2, 6.6 and the viscosity were 9.1, 8.6, 8.2, 5.3 for yogurt made with standard pectin and yogurt made with pectin extracted from tomatoes peels, and yogurtmade with pectin extracted from beet peels and pectin-free milk, respectively and the same order for color 9.3, 8.2 and 7.8. To know the ability of pectin to catch water, the yogurtwas recycled in the aforementioned treatments after milk was manufactured at a low solid rate material of (10%) and the incubation period was extended to 24 hours to help the whey become clear and it was found that the pectin-free milk had exuded the whey, while the standard pectin was able to prevent the extruding entirely while there was littleexudation in the treatment containing the pectin of tomatoes. There was more exudation in the treatment containing the pectin of the beet.
KE Sharquie, AA Noaimi, AG Al-Ghazzi, Journal of Dermatology & Dermatologic Surgery, 2015 - Cited by 19
This research presents and discuss the results of experimental investigation carried out on geogrids model to study the behavior of geogrid in the loose sandy soil. The effect of location eccentricity, depth of first layer of reinforcement, vertical spacing, number and type of reinforcement layers have been investigated. The results indicated that the percentage of bearing improvement a bout (22 %) at number of reinforced layers N=1 and about (47.5%) at number of reinforced layers N=2 for different Eccentricity values when depth ratio and vertical spacing between layers are (0.5B and 0.75B) respectively
This work presents the construction of a test apparatus for air-conditioning application that is flexible in changing a scaled down adsorbent bed modules. To improve the heat and mass transfer performance of the adsorbent bed, a finned-tube of the adsorbent bed heat exchanger was used. The results show that the specific cooling power (SCP) and the coefficient of performance (COP) are 163 W/kg and 0.16, respectively, when the cycle time is 40 min, the hot water temperature is 90oC, the cooling water temperature is 30oC and the evaporative water temperature is 11.4oC.
In this paper, we present new algorithm for the solution of the nonlinear high order multi-point boundary value problem with suitable multi boundary conditions. The algorithm is based on the semi-analytic technique and the solutions are calculated in the form of a rapid convergent series. It is observed that the method gives more realistic series solution that converges very rapidly in physical problems. Illustrative examples are provided to demonstrate the efficiency and simplicity of the proposed method in solving this type of multi- point boundary value problems.
Background : It has been suggested that pretreatment with a statin agent prior to
myocardial infarction limits myocardial
creatine kinase release, and thus may act to
limit myocardial infarct size in humans.
Objective : To examine the effect of very
early statin initiation for acute myocardial
infarction (AMI), to the extent of
myonecrosis as manifested by peak serum
creatine kinase levels.
Methods : Patients with AMI admitted to AlKindy teaching hospital cardiac care unit
from 1st February 2007 to 28th February
2008, who fulfilled the inclusion criteria
cited in the present study, were randomly
assigned into two study groups. The statin
group patients have received a single oral
dose of 40 mg
Neuro-ophthalmic disorders are often documented individually for each illness, with little data available on their overall incidence and pattern. The overall incidence of neuro-ophthalmic illnesses in Iraq is still not recorded. This study aimed to evaluate the clinical, demographic, and etiological features of patients seeking consultation at an Iraqi neuro-ophthalmology clinic. A prospective cross-sectional observational research was conducted at the Janna Ophthalmic Center in Baghdad, Iraq. The center serves a diverse patient population from various governorates. All newly diagnosed patients with neuro-ophthalmic disorders who visited the neuro-ophthalmological clinic, regardless of gender or age group, were included. The neuro-ophthalmo
... Show MoreThe present paper deals with experimental investigation of the performance of air cooled split air conditioner, with evaporative water mist pre cooling to increase the cooling capacity and reduce the consumption power under hot and dry climate. This investigation considers how the performance can be enhanced by using water mist to pre-cool ambient air entering the condensers by adiabatic cooling process which depends on the ambient air wet bulb temperature; as well the condensing temperature and condensing pressure will be decreased accordingly. So the cooling capacity would be increased and consumption power would be decreased, consequently the energy ratio, EER would be improved. The performance of air cooled air conditioner with water
... Show MoreTo promote sustainable steel-concrete composite structures, it is essential to develop special shear connectors that facilitate accelerated construction and deconstruction. A lockbolt demountable shear connector (LBDSC) was recently proposed. While the LBDSC has been evaluated using horizontal and vertical (standard) push-out tests, it is essential to further assess the disassembly mechanism and the positive flexural performance of prefabricated demountable composite beams (PDCBs) under both serviceability and ultimate limit states. Two full-scale test specimens of PDCBs with LBDSC were designed with partial shear connections and assessed using a three or four-point load beam setup under both cyclic and static monotonic loading conditions.
... Show More