The major objective of this study is to establish a network of Ground Control Points-GCPs which can use it as a reference for any engineering project. Total Station (type: Nikon Nivo 5.C), Optical Level and Garmin Navigator GPS were used to perform traversing. Traversing measurement was achieved by using nine points covered the selected area irregularly. Near Civil Engineering Department at Baghdad University Al-jadiriya, an attempt has been made to assess the accuracy of GPS by comparing the data obtained from the Total Station. The average error of this method is 3.326 m with the highest coefficient of determination (R2) is 0.077 m observed in Northing. While in the Easting the average error is 4.634 m with (R2) 0.099 m observed. The average error 5.513 m with (R2) is 0.071 m is observed in Reduced Level. The accuracy assessments of the interpolation methods (Total Station and Level) have been calculated using the average error 0.240 m with (R2) is 0.735 m is observed in Reduced Level. The GIS 10.3 program can automatically transform the saved data to text format and produce digital plans with attribute.
The reaction of L-ascorbic acid with the tirchloroacetic acid in the presence of potassium hydroxide gave new product Bis[O,O-2,3;O,O-5,6(chlorocarboxylicmethyliden)]Lascorbic acid (H2L) which was isolated and characterized by 1H,13C-NMR, elemental analysis (C,H,N), UV-Visible and Fourier Transform Infrared (FTIR). The complexes of the ligand (H2L) with metal ions, M+2= (Cu, Co, Ni, Cd and Hg) were synthesized and characterized by FTIR, UV-Visible, molar conductance, atomic absorption, magnetic susceptibility and the molar ratio. The analysis evidence showed the binding of the metal ions with (H2L) through the bicarboxylato group manner resulting in six-coordinated metal ion. The TLC for (H2L) and complexes showed one spot for eac
... Show MoreIl semble que Khattabi était un linguiste, avec un endroit linguistique pour comprendre les textes de conversations et des mots étranges en particulier. Langue, et chacun avait ses arguments et ses preuves. Ses corrections incluaient la mélodie dans les mouvements, telle qu'une dilution plus serrée, la dilution de l'agitateur, le remplacement d'un autre mouvement, ou une autre rotation des mouvements, et le changement de structure morphologique du mot qui en résultait, ainsi que l'alerte sur les conséquences des lettres, Certaines de ces erreurs sont dues à la langue, et certaines sont considérées comme un type de déformation ou de fausse représentation connue de certains spécialistes, ce qui constitue un précédent louable
... Show MoreA set newly complexes with the general formula [M(L)Cl2] are resulting from the reaction of a new schiff base ligand [Ethyl (6R,7R)-7-((E)-2-((2-ethoxy-2- oxoethoxy)imino)-2-(2-(((E)-4-nitrobenzylidene) amino) thiazol -4- yl) acetamido) -8- oxo -3- vinyl -5- thia -1-aza bicyclo [4. 2.0] oct -2- ene -2- carboxylate] (L). This ligand was derived from the reaction of the two substances 4-nitrobenzaldehyde and precursor (P). Reaction the ligand with metal ions M= Mn(II), Co(II), Ni(II), Cu(II) and Cd(II) afforded new complexes which are characterized by FT-IR and Electronic Spectra. These measurements indicate that the complexes have a tetrahedral geometry. The Penicillin-Binding Protein 3 (PBP3) of Staphylococcus aureus and the target protein
... Show MoreThe experiment was conducted at the plant tissue culture laboratory of the Department of Horticulture and Garden Engineering College of Agricultural Engineering Sciences, University of Baghdad, in order to study the effect of some growth regulators on propagation an stimulation production of volatile oil compounds of rosemary plant Rosmarinus officinlis using two vegetative parts (apical and lateral buds). Factorial experiment was implemented in completely randomized design with twenty replications. The results indicated that culturing the apical meristem on the medium Murashige and Skoog (MS) media with 0.5 mg.l-1 (BA) with 0.1 mg.l-1 of NAA gave the highest response rate of 100%. As for the doubling stage, the levels of BAA and IAA (Indol
... Show Moreالمستخلص:
في هذا البحث , استعملنا طرائق مختلفة لتقدير معلمة القياس للتوزيع الاسي كمقدر الإمكان الأعظم ومقدر العزوم ومقدر بيز في ستة أنواع مختلفة عندما يكون التوزيع الأولي لمعلمة القياس : توزيع لافي (Levy) وتوزيع كامبل من النوع الثاني وتوزيع معكوس مربع كاي وتوزيع معكوس كاما وتوزيع غير الملائم (Improper) وتوزيع
... Show MoreThe study aimed at designing compound exercises using added weight on some skill abilities in youth soccer players aged (17 – 19) years old. The researcher sued the experimental method on (30) players aged (17 – 19) years old from Al Zawraa Sport Club. The subjects were divided into three groups and the training program was applied for (8) weeks with (3) training sessions per week. The data was collected and treated using proper statistical operations to conclude that compound exercises with weights between improved the subjects compared to the groups that did not use the added weights. Finally, the researchers recommended the necessity of using compound exercises using added weights during training sessions for youth soccer pla
... Show MoreThe preparation, spectroscopic characterisation of complexes derived from the mixed ligands with CdII, ZnII and CoII metal ions with Schiff base, Dithiocarbamates (DTCs) and 8-Hydroxyquinoline are reported. The compounds that prepared have been defined via; chloride content, F.T-IR, UV-Vis 1H-NMR spectroscopy and C.H.N.S, as well as conductance and magnetic susceptibility.All data which collected from such methods specified complexes with 6 coordinates in solution and solid states. The biologicalactivity that is related to all the prepared compounds which were screened for their antimicrobial activitiesagainst (G+ and (G-)). The data that collected from biological activity indicate that complexes will have extra activity against such tested
... Show MoreThe mass collision energy loss (dE/dX), the mass radiative energy loss (Srad/) and the total mass stopping power of electrons in the energy range of 0.01 MeV up to 1000 MeV has been calculated for Lung, Urea and Skin. The results of the present work for the mass collision stopping power of electrons in Lung, Urea and Skin are in excellent agreement with the standard results given by ESTAR program, where the maximum percentage error between the present calculated values and that of ESTAR program in Lung tissue, Urea and Skin tissue is 0.27%, 0.3% and 0.8% respectively. The mass radiative energy loss of electrons in the same energy range is also calculated using a modified equation, and the results are found to be in very good agreem
... Show More