Preferred Language
Articles
/
hBaYfIwBVTCNdQwCMPy-
Azo Coupling Reaction for indirect Spectrophotometric Determination of Furosemide using Resorcinol as a Reagent
...Show More Authors
Abstract<p>A simple and accurate method to determinate furosemide (FUR) based on converting the secondary amine to primary amine with acidic hydrolysis then azotization by nitrous acid and coupled with resorcinol as a coupling agent in aqueous medium at pH 13. The optical characteristic like beers law limit found to be (0.25-2.5) μg.ml<sup>−1</sup>, detection and quantification limits (0.0196) (0.0654) μg.ml<sup>−1</sup>respectivly and Sandel sensitivity was 0.006738 μg.cm<sup>−2</sup>. The least-square method was used to evaluate the regression equation and the correlation coefficient. The resulted azo dye has a maximum absorbance at 430 nm with light orange color. The developed method was successfully applied to determinate FUR in its formulation with 84-105 % as a recovery with a relative standard deviation not more 2% and less than 5% relative error. To validate the proposed method, the standard addition method was applied to evaluate FUR in different formulation sources.</p>
Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Jun 01 2014
Journal Name
Baghdad Science Journal
Synthesis, Characterization and Textural Analysis of Functionalized Mesoporous Silica Using Sodium Silicate as Precursor and Silicone Surfactant as Template
...Show More Authors

Three mesoporous silica with different functional group were prepared by one-step synthesis based on the simultaneous hydrolysis and condensation of sodium silicate with organo - silane in the presence of template surfactant polydimethylsiloxane - polyethyleneoxide (PDMS - PEO). The prepared materials were characterized by Fourier transform infrared spectroscopy (FTIR), thermogravimetric analysis (TGA), atomic force microscopy (AFM) and nitrogen adsorption/desorption experiments. The results indicate that the preparation of methyl and phenyl functionalized silica were successful and the mass of methyl and phenyl groups bonded to the silica structure are 15, 38 mmol per gram silica. The average diameter of the silica particles are 103.51,

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Oct 02 2020
Journal Name
Biochemical & Cellular Archives
Retinoids and rexinoids as vitamin A analogs.
...Show More Authors

Vitamin A, namely retinol is still the most proper agent for modulating so many biochemical reactions and biological functions in different tissues and organs. In addition to the provitamins A and α, βand γ-carotenoids that are present in various foods from either animal or plant origin, retinoids and rexinoids form the natural and synthetic analogs that are chemically related or unrelated and can be added as food supplements for deficiency disorders of vitamin A or used to alleviate or treat certain health problems such as skin carcinoma, acne, skin aging and dermatitis.

Publication Date
Wed Jan 02 2013
Journal Name
Journal Of The Faculty Of Medicine Baghdad
Rotavirus infection as a cause watery diarrhea
...Show More Authors

SummaryBackground: Rotavirus infection is the most commoncause of watery viral diarrhea in children younger than 5 years of age; it is a major cause of childhood morbidity and mortality.Objective:The aim of the study is todetermine the clinical picture, age distribution of patients with rotavirus infection and their maternal educational background.Patients &methods: A total of 202 patients suffering from diarrhea were included in this study, over 6 months period( from 1stof March 2011to 30th of August 2011),in Children Welfare Teaching hospital. History and physical examinationwere carried out, anthropometrics measures were done and plotted on Centers for Disease Control& World Health Organization charts to determine the nut

... Show More
View Publication
Crossref
Publication Date
Tue Jun 01 2021
Journal Name
The Journal Of Continuing Education In Nursing
Debate as a Teaching Strategy in Nursing
...Show More Authors

Debate is a teaching strategy in nursing education that enhances students' critical thinking. Although debate can be an effective teaching strategy, it is not without limitations. This article discusses the advantages and disadvantages of debate as a teaching strategy in nursing. Also, evaluating debates and choosing topics are highlighted. [ J Contin Educ Nurs . 2021;52(6):263–265.]

View Publication
Scopus (4)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Annals Of Tropical Medicine And Public Health
Dithiocarbamates derivatives as anticancer agents: A Review
...Show More Authors

View Publication
Crossref (9)
Crossref
Publication Date
Wed Jun 28 2023
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
PREPARATION OF A COMBINATION OF NANO- MEDICINAL PLANTS AS ANTIOXIDANTS AND MICROORGANISMS: PREPARATION OF A COMBINATION OF NANO- MEDICINAL PLANTS AS ANTIOXIDANTS AND MICROORGANISMS
...Show More Authors

ABSTRACT

            The controversy is currently revolving around industrial additives, including antioxidants, their negative effects on consumer health and the emergence of various and various diseases, which led scientists and researchers to intensify most studies on natural antioxidants and their synthesis from medicinal plants mentioned in ancient medicine and in divine books as potential antioxidants of increasing importance. Therefore, this study was designed to synthesize silver nitrate particles from plant leaf extracts (Figs, Olives, and Moringa) and study their effect on bacterial inhibition of each of the undesirable Coliform bacteria (E-Coli,

... Show More
View Publication Preview PDF
Publication Date
Thu Jul 01 2021
Journal Name
Journal Of Pharmaceutical And Biomedical Analysis
An optoelectronic flow-through detectors for active ingredients determination in the pharmaceutical formulations
...Show More Authors

An optoelectronic flow-through detector for active ingredients determination in pharmaceutical formulations is explained. Two consecutive compact photodetector’s devices operating according to light-emitting diodes-solar cells concept where the LEDs acting as a light source and solar cells for measuring the attenuated light of the incident light at 180˚ have been developed. The turbidimetric detector, fabricated of ten light-emitting diodes and five solar cells only, integrated with a glass flow cell has been easily adapted in flow injection analysis manifold system. For active ingredients determination, the developed detector was successfully utilized for the development and validation of an analytical method for warfarin determination

... Show More
Scopus (21)
Crossref (12)
Scopus Clarivate Crossref
Publication Date
Thu Jul 01 2021
Journal Name
Journal Of Pharmaceutical And Biomedical Analysis
An optoelectronic flow-through detectors for active ingredients determination in the pharmaceutical formulations
...Show More Authors

An optoelectronic flow-through detector for active ingredients determination in pharmaceutical formulations is explained. Two consecutive compact photodetector’s devices operating according to light-emitting diodes-solar cells concept where the LEDs acting as a light source and solar cells for measuring the attenuated light of the incident light at 180˚ have been developed. The turbidimetric detector, fabricated of ten light-emitting diodes and five solar cells only, integrated with a glass flow cell has been easily adapted in flow injection analysis manifold system. For active ingredients determination, the developed detector was successfully utilized for the development and validation of an analytical method for warfarin determination

... Show More
View Publication Preview PDF
Scopus (21)
Crossref (12)
Scopus Clarivate Crossref
Publication Date
Tue Dec 01 2009
Journal Name
Iraqi Journal Of Physics
Spectrophotometrically Analysis of PMMA as a low – Doses Dosimeter
...Show More Authors

Polymethylmethacrylate film (PMMA) of thickness 75 μm was evaluated Spectrophotometrically for using it as a low-doses gamma radiation dosimeter. The doses were examined in the range 0.1 mrad-10 krad. Within an absorption band of 200-400 nm, the irradiated films showed an increase in the absorption intensity with increasing the absorbed doses. Calibration curves for the changes in the absorption differences were obtained at 218, 301, and 343 nm. At 218 nm the response for the absorbed doses is a linear in the range 10 mrad- 10 krad. Hence it is recommended to be adopted as an environmental low doses dosimeter

View Publication Preview PDF
Publication Date
Wed Aug 28 2024
Journal Name
World Academy Of Sciences Journal
Serum angiopoietin‑1 as a biomarker of missed miscarriage
...Show More Authors

View Publication
Scopus (1)
Crossref (1)
Scopus Crossref