A linear engine generator with a compact double-acting free piston mechanism allows for full integration of the combustion engine and generator, which provides an alternative chemical-to-electrical energy converter with a higher volumetric power density for the electrification of automobiles, trains, and ships. This paper aims to analyse the performance of the integrated engine with alternative permanent magnet linear tubular electrical machine topologies using a coupled dynamic model in Siemens Simcenter software. Two types of alternative generator configurations are compared, namely long translator-short stator and short translator-long stator linear machines. The dynamic models of the linear engine and linear generator, validated with lab-scale prototypes, are applied to investigate the influence of alternative topologies of the generator on system performance. The coupled model will facilitate the early design phase and reveal the optimal match of the key parameters of the engine and generator. Then, experimental tests on an integrated compressor cylinder-generator prototype were successfully performed, and it is shown that this concept is feasible and electrical power and compressed working fluid, such as air, can be generated by this prototype.
For the most reliable and reproducible results for calibration or general testing purposes of two immiscible liquids, such as water in engine oil, good emulsification is vital. This study explores the impact of emulsion quality on the Fourier transform infrared (FT-IR) spectroscopy calibration standards for measuring water contamination in used or in-service engine oil, in an attempt to strengthen the specific guidelines of ASTM International standards for sample preparation. By using different emulsification techniques and readily available laboratory equipment, this work is an attempt to establish the ideal sample preparation technique for reliability, repeatability, and reproducibility for FT-IR analysis while still considering t
... Show MoreConstruction of artificial higher order protein complexes allows sampling of structural architectures and functional features not accessible by classical monomeric proteins. Here, we combine in silico modelling with expanded genetic code facilitated strain promoted azide-alkyne cycloaddition to construct artificial complexes that are structurally integrated protein dimers and demonstrate functional synergy. Using fluorescent proteins sfGFP and Venus as models, homodimers and heterodimers are constructed that switched ON once assembled and display enhanced spectral properties. Symmetrical crosslinks are found to be important for functional enhancement. The determined molecular structure of one artific
It is well-known that the existence of outliers in the data will adversely affect the efficiency of estimation and results of the current study. In this paper four methods will be studied to detect outliers for the multiple linear regression model in two cases : first, in real data; and secondly, after adding the outliers to data and the attempt to detect it. The study is conducted for samples with different sizes, and uses three measures for comparing between these methods . These three measures are : the mask, dumping and standard error of the estimate.
Gymnastics play from sports games that need to use appropriate methods and strategies that address mental abilities and that let the learner create and think about better performance with the supervision and guidance of the teacher. The researcher has chosen meditative thinking, which is a kind of thinking that needs to be taken care of. It is thinking about the situation in front of the individual, analysing it to his elements and drawing up plans that need to be understood with a view to reaching the results required by the situation and evaluating the results in the light of the plans. The analysis of the situation looks to different elements and look for internal relationships between these elements in this case. The problem is that fem
... Show MoreWhen the depth of stressed soil is rather small, Plate Load Test (PLT) becomes the most efficient test to estimate the soil properties for design purposes. Among these properties, modulus of subgrade reaction is the most important one that usually employed in roads and concrete pavement design. Two methods are available to perform PLT: static and dynamic methods. Static PLT is usually adopted due to its simplicity and time saving to be performs in comparison with cyclic (dynamic) method. The two methods are described in ASTM standard.
In this paper the effect of the test method used in PLT in estimation of some mechanical soil properties was distinguished via a series of both test methods applied in a same site. The comparison of
... Show MoreThe aim of this study was to establish the existence and interaction of TMPRSS2 – ERG gene fusion status with clinicopathological features of prostate cancer patients. This research consisted of 123 embedded formalin-fixed tissues obtained from the prostate tumor patients. The above gene fusion is detected through the technique of fluorescent in situ hybridization (FISH) by means of a triple color probe. Seven samples have not been scored due to technical difficulties and 46 patients have fusion (39.6%), while the remaining (70) have not been seen with fusion. Of the 46 fusion-positive, 17 (36%) were caused by ERG-translocation, of the other 29 (63%) were caused by the interstitial segment deletion between the two genes due to the
... Show MoreSediment accumulated in sewers is a major concern source as it induces numerous operational and environmental problems. For instance, during wet weather flow, the re-suspension of this sediment accompanied by the combined sewer overflow may cause huge pollutant load to the receiving water body. The characteristics of the sewer sediment are important as it shapes its behaviour and determines the extent of the pollution load. In this paper, an investigation of sewer sediment and its characterization is done for a case study in Baghdad city. Sediment depth covers more than 50% of the sewer cross-sectional area; several operational causes are comprised to cause this huge depths of sediment depositions. The testing and analysis of the s
... Show More