In this study, the Halder-Wagner method was used for an analysisX-ray lines of Tio2 nanoparticles. Where the software was used to calculate the FWHM and integral breath (β) to calculate the area under the curve for each of the lines of diffraction. After that, the general equation of the halder- Wagner method is applied to calculate the volume (D), strain (ε), stress (σ), and energy per unit(u). Volume (β). Where the value of the crystal volume was equal to (0.16149870 nm) and the strain was equal to (1.044126), stress (181.678 N / m2), and energy per unit volume (94.8474 J m-3).The results obtained from these methods were then compared with those obtained from each of the new paradigm of the HalderWagner method, the Shearer development method, and the Munshi-Shearer method, and their results for new the Halder - Wagner method crystal volume model (0.16487774nm), strain (1.28564), retinal stress (223.7021 N / m2), energy per unit volume (109.333 J m-3) and for Munshi-Shearer crystal volume (0.14985728 nm) , and the development of Shearer retinal stress (162.0636 N / m2) and strain (0.9314), energy per unit volume (75.473 J m-3).
Background: It has been well known that the success of mandibular implant- retained overdenture heavily depends on initial stability, retention and long term osseointegration this is might be due to optimal stresses distribution in surrounding bones. Types of mandibular implant- retained overdenture anchorage system and number of dental implants play an important role in stresses distribution at the implant-bone interface. It is necessary to keep the stresses below the physiologic tolerance level of the bone .since. And it is difficult to measure these stresses around bone in vivo. In the present study, finite element analysis used to study the stresses distribution around dental implant supporting Mandible implant retained overdenture Mate
... Show MoreThe study aims to show the correlation between inflation rates and the volume of private sector deposits in Jordan on one hand, and Amman Stock Exchange index for the period of 1999-2017. The study used the “Vector Auto Regression” model. Different types of tests are used such as: The “Johansen Co integration” test of joint integration, “Granger causality” test, the “Analysis of Variance Decomposition”, and “Impulse response Function” test.
The results showed there is a positive-one-way causal effect from Amman Stock Exchange index to inflation. Also, a one-way causal effect that comes from Amman Stock Exchange index to the size of private sec
... Show MoreThe Estimation Of The Reliability Function Depends On The Accuracy Of The Data Used To Estimate The Parameters Of The Probability distribution, and Because Some Data Suffer from a Skew in their Data to Estimate the Parameters and Calculate the Reliability Function in light of the Presence of Some Skew in the Data, there must be a Distribution that has flexibility in dealing with that Data. As in the data of Diyala Company for Electrical Industries, as it was observed that there was a positive twisting in the data collected from the Power and Machinery Department, which required distribution that deals with those data and searches for methods that accommodate this problem and lead to accurate estimates of the reliability function,
... Show MoreThe Hopfield network is one of the easiest types, and its architecture is such that each neuron in the network connects to the other, thus called a fully connected neural network. In addition, this type is considered auto-associative memory, because the network returns the pattern immediately upon recognition, this network has many limitations, including memory capacity, discrepancy, orthogonally between patterns, weight symmetry, and local minimum. This paper proposes a new strategy for designing Hopfield based on XOR operation; A new strategy is proposed to solve these limitations by suggesting a new algorithm in the Hopfield network design, this strategy will increase the performance of Hopfield by modifying the architecture of t
... Show MoreNew microphotometer was constructed in our Laboratory Which deals with the determination of Molybdenum (VI) through its Catalysis effect on Hydrogen peroxide and potasum iodide Reaction in acid medium H2SO4 0.01 mM. Linearity of 97.3% for the range 5- 100 ppm. The repeatability of result was better than 0.8 % 0.5 ppm was obtanined as L.U. (The method applied for the determination of Molybdenum (VI) in medicinal Sample (centrum). The determination was compared well with the developed method the conventional method.
In this paper, A.C conductivity of micro and nano grain size- TiO2 filled epoxy composites is measured. The dielectric material used is epoxy resin, while micro and nano-sized titanium dioxide (TiO2) of grain size (1.5μm, and 50nm) was used as filler at low filler concentrations by weight (3%, and 5%). Additionally the effect of annealing temperature range (293-373)º K and at a frequency range of 102-106 Hz on the A.C conductivity of the various specimens was studied.
The result of real permittivity for micro and nanocomposite show that the real permittivity increases with decreasing frequency at range of 102-106Hz. The micron-filled material has a higher real relative permittivity than the nano-filled this is true at all the temper
Rheumatoid arthritis (RA) is a common inflammatory disease that associated with increased morbidity and mortality due to accelerated atherosclerosis. Rosuvastatin is a unique hydroxy methyl glutaryl Co A (HMGCoA) reductase inhibitor that has anti inflammatory effects.
The aim of this study was to evaluate the effect of rosuvastatin as adjuvant therapy to methotrexate (MTX) on lipid profile and its possible cardioprotective effect in RA patients. A double blinded placebo controlled clinical trial with 8 weeks follow up periods at which 40 patients with active RA using MTX were randomized into 2 groups to receive either rosuvastatin 10mg or placebo as adjuvant therapy to MTX. In addition to twenty healthy subjects as control group.
... Show More