Preferred Language
Articles
/
ghbkvIsBVTCNdQwCU9nN
Cover crop influence on soil water dynamics for a corn–soybean rotation
...Show More Authors
Abstract<p>Crop production is reduced by insufficient and/or excess soil water, which can significantly decrease plant growth and development. Therefore, conservation management practices such as cover crops (CCs) are used to optimize soil water dynamics, since CCs can conserve soil water. The objective of this study was to determine the effects of CCs on soil water dynamics on a corn (<italic>Zea mays</italic> L.)–soybean [<italic>Glycine max</italic> (L.) Merr.] rotation at three soil depths over 3 yr. The study was conducted at the Chariton County Cover Crop Soil Health Research and Demonstration Farm (CCSH) in Missouri. Initial CC establishment occurred in 2012. Volumetric soil water content (VWC) was monitored at 15‐min intervals with calibrated Waterscout SM100 soil moisture sensors (Spectrum Technologies) at three depths (10, 20, and 30 cm) in 2016, 2017, and 2018. Cover crop soils maintained numerically higher VWC values compared with no CC (NCC) at both 10‐ and 20‐cm depths throughout the study period where the differences were significant in some weeks. The subsurface soil water recharge was greater in CC soils at both 10‐ and 20‐cm depths compared with NCC in March 2017. The results imply that CC soils have maintained higher VWC levels during vegetative period of the CC growth where the differences were significant in some weeks compared with NCC at all three soil depths. These findings can be used to promote CC adoption for better soil water storage and develop CC management plans for corn–soybean rotations on claypan soils.</p>
Scopus Clarivate Crossref
View Publication
Publication Date
Thu Feb 12 2026
Journal Name
Journal Of Baghdad College Of Dentistry
The Fluoride Concentration of Bottled Drinking Water in Al-Basra City, Iraq
...Show More Authors

Background: This study aimed to determine the amount of fluoride in commercially available bottled drinking water in Al-Basra city, Iraq Materials and Methods: Eleven brands of bottled drinking water were obtained from supermarkets in Al-Basra city, Iraq. Five samples of 10 ml. were taking from each one of brands and the fluoride was determined by using fluoride ion selective electrode. Results: The highest fluoride concentration was present in BADIOT brand (1.174 mg/L) while the lowest was in Barakat brand (0.038 mg/L). One way ANOVA test showed a highley significant difference among different commercially branded types. Coclusions: Bottled water available in Al-Basra city contains less concentration of fluoride ion than normal values

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Tue Sep 08 2020
Journal Name
Baghdad Science Journal
Turbid of Water By Using Fuzzy C- Means and Hard K- Means
...Show More Authors

In this research two algorithms are applied, the first is Fuzzy C Means (FCM) algorithm and the second is hard K means (HKM) algorithm to know which of them is better than the others these two algorithms are applied on a set of data collected  from the Ministry of Planning on the water turbidity of five areas in Baghdad to know which of these areas are less turbid in clear water to see which months during the year are less turbid in clear water in the specified area.

View Publication Preview PDF
Scopus (2)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Tue Jun 30 2015
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Furfural Degradation in Waste Water by Advanced Oxidation Process Using UV/H2O2
...Show More Authors

Furfural is one of the one of pollutants in refinery industrial wastewaters. In this study advanced oxidation process using UV/H2O2 was investigated for furfural degradation in synthetic wastewater. The results from the experimental work showed that the degradation of furfural decreases as its concentration increases, reaching 100% at 50mg/l furfural concentration and increasing the concentration of H2O2 from 250 to 500 mg/l increased furfural removal from 40 to 60%.The degradation of furfural reached 100% after 90 min exposure time using two UV lamps, where it reached 60% using one lamp after 240 min exposure time. The rate of furfural degradation k increased at the pH and initial concentratio

... Show More
View Publication Preview PDF
Publication Date
Tue Mar 01 2022
Journal Name
Journal Of Engineering
Performance Evaluation the Turbidity Removal Efficiency of AL-Muthana Water Treatment Plant
...Show More Authors

Turbidity is a visual property of water that expresses the amount of suspended substances in the water. Its presence in quantities more significant than the permissible limit makes the water undrinkable and reduces the effectiveness of disinfectants in treating pathogens. On this basis, turbidity is used as a basic indicator for measuring water quality. This study aims to evaluate the removal efficiency of AL- Muthanna WTP. Water turbidity was used as a basic parameter in the evaluation, using performance improvement evaluation and data from previous years (2016 to 2020). The average raw water turbidity was 26.7 NTU, with a minimum of 14 NTU, with a maximum of 48 NTU. Water turbidity value for 95% of settling daily reading data was

... Show More
Crossref (5)
Crossref
Publication Date
Wed Aug 29 2018
Journal Name
Journal Of Engineering
Desalting of RO Waste and Drainage Water by Direct Contact Membrane Distillation
...Show More Authors

Direct contact membrane distillation is an effective method for production of fresh water from saline water. In this study two samples were used as feed solutions; the first one was RO waste from Al-Hilla Coca-Cola Factory (TDS= 2382 mg/l) and the other was Haji Ali drainage water (TDS= 4127 mg/l). Polytetrafluoroethylene (PTFE) hydrophobic membrane supported with polypropylene (PP) was used as flat sheet form with plate and frame cell. Results proved that membrane distillation is an effective technique to produce fresh water with high quality from brine with low salinity content. With membrane area of 8x8 cm2, the volume of treated water decreased from 34.97 ml at first half hour to 33.02 ml after 180 min of

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Mar 01 2022
Journal Name
Journal Of Engineering
Performance Evaluation the Turbidity Removal Efficiency of AL-Muthana Water Treatment Plant
...Show More Authors

Turbidity is a visual property of water that expresses the amount of suspended substances in the water. Its presence in quantities more significant than the permissible limit makes the water undrinkable and reduces the effectiveness of disinfectants in treating pathogens. On this basis, turbidity is used as a basic indicator for measuring water quality. This study aims to evaluate the removal efficiency of AL- Muthanna WTP. Water turbidity was used as a basic parameter in the evaluation, using performance improvement evaluation and data from previous years (2016 to 2020). The average raw water turbidity was 26.7 NTU, with a minimum of 14 NTU, with a maximum of 48 NTU. Water turbidity value for 95% of settling daily readi

... Show More
View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Tue May 16 2023
Journal Name
Journal Of Engineering
EXPERIMENTAL INVESTIGATION OF INDIVIDUAL EVACUATED TUBE HEAT PIPE SOLAR WATER HEATING SYSTEMS
...Show More Authors

lar water heating systems with heat pipes of three diameter groups of 16, 22 and 28.5 mm. The first and third groups had evaporator lengths of 1150, 1300 and 1550 mm. The second group had an additional length of 1800 mm. all heat pipes were of fixed condenser length of 200 mm. Ethanol at 50% fill charge ratio of the evaporator volume was used as the heat pipes working fluid. Each heat pipe condenser section was inserted in a storage tank and the evaporator section inserted into an evacuated glass tube of the Owens- Illinois type. The combined heat pipe and evacuated glass tube form an active solar collector of a unique design.
The resulting ten solar water heating systems were tested outdoors under the meteorological conditions of Bag

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Nov 01 2016
Journal Name
Journal Of Economics And Administrative Sciences
Use Dynamic Bayesian network to estimate the reliability of Adamia Water Network
...Show More Authors

Abstract\

In this research, estimated the reliability of water system network in Baghdad was done. to assess its performance during a specific period. a fault tree through static and dynamic gates was belt and these gates represent logical relationships between the main events in the network and analyzed using dynamic Bayesian networks . As it has been applied Dynamic Bayesian networks estimate reliability by translating dynamic fault tree to Dynamic Bayesian networks and reliability of the system appreciated. As was the potential for the expense of each phase of the network for each gate . Because there are two parts to the Dynamic Bayesian networks and two part of gate (AND), which includes the three basic units of the

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Jan 01 2011
Journal Name
Iraqi Journal Of Physics
Measurement of Background Radioactivity in Baghdad's Main Water Supply Stations: Sediment Samples
...Show More Authors

Sediment samples were collected from main water processing and supply plants in Baghdad, and tested for radioactivity from both natural and artificial sources. These stations are: East Dijla (Tigris), Al-Kadisia, Al-Karama, Al-Rasheed, Al-Sader, Al-Wathba, and Al-Wihda supply stations. Qualitative measurements were made, and the results showed that most sediments exhibited natural radioactive level and sometimes less than the international regular standards. Specially, K-40 and Ra-226 results were much less than the standards for radioactive concentrations. Ac-228 concentration was found rather than Th-232 (in Al-Sader and Al-Wihda samples) but with low concentrations of about 10-15 Bg/kg and detection confidence ~45% , and Ce-141 and Be

... Show More
View Publication Preview PDF
Publication Date
Fri Apr 01 2011
Journal Name
Desalination
Cathodic protection system of copper–zinc–saline water in presence of bacteria
...Show More Authors

Rate of zinc consumption during the cathodic protection of copper pipeline which carries saline water was measured by weight loss technique in the absence and presence of bacteria. Variables studied were solution flow rate, temperature, time and NaCl concentration. It was found that within the present range of variables; the rate of zinc consumption increases with the increase of all operating conditions. The presence of bacteria increases the zinc consumption. Fourth order multi-term model and one-term model were suggested to represent the consumption data. Nonlinear regression analysis was used to estimate the coefficients of these models, while statistical analysis was used to determine the effect of each coefficient. Both models were re

... Show More
Crossref (34)
Crossref