Preferred Language
Articles
/
ghZO2YcBVTCNdQwCQWpx
Evaluation the Role of CD4 and CD8 Reducing the Deterioration of COVID-19 Iraqi Patients
...Show More Authors

Since its start spreed "Severe acute respiratory syndrome coronavirus 2" was discovered in Wuhan, China.that is chargeable COVID-19, a pandemic virus, has end up a widespread fitness hassle everywhere in the global Over 2.1 million people have been affected. We analyze serum concentration of CD4 marker and CD8 marker depend in COVID-19 sufferers, and to make clear a relationship between these variables and disorder Progression and severity For those purpose, (158) sufferers with COVID-19 (showed with the aid of using polymerase chain reaction) and (22) seemingly wholesome human beings have been protected withinside the present day examine and taken into consideration as a manipulate group. All examine population (sufferers and manipulate) have been subjected to the assessment of serum awareness of CD4 marker and CD8 marker. COVID-19 sufferers displayed a huge elevation withinside the tiers of parameters protected on this examine while in comparison with wholesome controls. We additionally observed that concentration of CD4 and CD8 high in sever ( CD4 5.68 ±0.16-CD8 961.74 ±49.48 ) than critical ( CD4 4.76 ±0.14- CD8 880.19 ±52.03 )and moderate (CD43.83 ±0.09 – CD8 647.52 ±44.54 ) groups with high significant different (P≤0.01(

Scopus Clarivate Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Nov 19 2020
Journal Name
Indonesian Journal Of Chemistry
Determination of Eugenol in Personal-Care Products by Dispersive Liquid-Liquid Microextraction Followed by Spectrophotometry Using <i>p</i>-Amino-<i>N,N</i>-dimethylaniline as a Derivatizing Agent
...Show More Authors

Two simple methods for the determination of eugenol were developed. The first depends on the oxidative coupling of eugenol with p-amino-N,N-dimethylaniline (PADA) in the presence of K3[Fe(CN)6]. A linear regression calibration plot for eugenol was constructed at 600 nm, within a concentration range of 0.25-2.50 μg.mL–1 and a correlation coefficient (r) value of 0.9988. The limits of detection (LOD) and quantitation (LOQ) were 0.086 and 0.284 μg.mL–1, respectively. The second method is based on the dispersive liquid-liquid microextraction of the derivatized oxidative coupling product of eugenol with PADA. Under the optimized extraction procedure, the extracted colored product was determined spectrophotometrically at 618 nm. A l

... Show More
View Publication Preview PDF
Scopus (5)
Crossref (6)
Scopus Clarivate Crossref