Background Obstructing dentinal tubules is a valuable approach for managing dentin hypersensitivity. Although various agents promote dentin remineralization, direct comparisons between theobromine, bioactive glass (BAG), and nano-hydroxyapatite (Nano-HAP) under simulated oral conditions remain limited. To fill this gap, this in vitro study aimed to evaluate and compare the effectiveness of these three treatments on exposed cervical dentin. The assessment focused on their chemical, morphological, and mechanical effects on dentin. Materials and methods Forty-eight human dentin slabs were obtained from the cervical portions of twelve sound premolar teeth. Baseline Raman spectroscopy and VMH tests were done to exclude outliers. All specimens were treated with 6 % citric acid (pH 2.0) for 2 min to remove the smear layer. They randomly assigned to four groups (n = 12): artificial saliva (AS), theobromine, BAG, and Nano-HAP. Evaluations were conducted using Raman spectroscopy (phosphate peak intensity at 960cm−1), Vickers microhardness testing (VMH), and morphological assessment under scanning electron microscopy (SEM). Results Theobromine, BAG, and nano-HAP groups demonstrated a statistically significant increase in Raman phosphate peak intensity (960cm−1) and Vickers microhardness values (p < 0.05), indicating surface remineralization. In contrast, the artificial saliva group exhibited a significant decrease in phosphate peak intensity and microhardness values (p < 0.05). Conclusion All tested agents significantly enhanced the Raman phosphate peaks and microhardness values compared to the control. Nano-HAP showed the highest potential for promoting the remineralization of exposed dentin surfaces. Within the study's limitations, it can be concluded that theobromine, BAG, and nano-HAP are effective in occluding dentinal tubules.
Many studies have evaluated the effect of platelet rich plasma (PRP) in the treatment of non-union fractures but few studies have investigated their effect on the union of femoral neck fractures or their functional outcome in young adults. The aim of this study was to evaluate the union time and functional outcome in young adult patients with femoral neck fracture managed by three cannulated screws injected with PRP and those managed by fixation only. This prospective study included 24 patients diagnosed with femoral neck fractures within 24 hours of presentation. Twelve cases in group A were managed by closed reduction and three cannulated screws fixation injected with PRP; twelve patients in group B were managed only by closed reduction a
... Show MoreBackground: Immediate implant placement in the maxillary anterior region was challenging, especially with the jumping gap and limited primary implant stability. Objective: To assess the autogenous dentin graft biomaterial's ability to improve the esthetic outcomes of an immediately inserted implant. Methods: Twenty patients with non-restorable retained roots in the maxillary non-molar region surrounded by natural sound teeth were included in this study after a complete clinical and radiological examination, including patient health and clinical fitness for the immediate dental implant procedure. A single dental implant was inserted for each patient, and the resulting jump distance was filled with the mineralized dentin graft and co
... Show MoreBackground: Vasospasm occurs commonly in the intracranial arteries as a complication of subarachnoid haemorrhage. On the other hand, extracranial Internal carotid artery (ICA) vasospasm is scarce, and it may occur due to mechanical manipulation during cerebral angiography. We report a case of cervical carotid artery vasospasm during diagnostic cerebral angiography, which caused anterior cerebral artery territory hypoperfusion, to discuss potential risk factors. Case description: For a 22-year-old female with a ten-year history of epilepsy on multiple drugs, brain magnetic resonance imaging (MRI) showed frontal periventricular developmental venous anomaly. Diagnostic catheter cerebral angiography was used to better identify the vas
... Show MoreObjective: To compare the efficacy and safety of isosorbide mononitrate (IMN) versus misoprostol used to induce labour for overdue pregnancy.
Setting: A prospective randomized clinical study conducted at AL-Elwiya Maternity Teaching Hospital in Baghdad from Jan. 2008 to Dec. 2008.
Method: One hundred and fifty women with over due pregnancy (past date and posterm pregnancy) referred for induction of labour with Bishop scores <_ 5 were randomly allocated to receive either forty mg isosorbide mononitrate (IMN) tablet as a single vaginal dose (n=75) or fifty mcg misoprostol vaginally (n=75) every six hrs for a maximum of three doses. Amniotomy and/or oxytocin infusion is considered when Bishop scores frankly progressed (augmentation
Background: The liver is one of the most common organs
injured after blunt abdominal trauma. The control of severe
hemorrhage remains a problem.
Methods: One-hundred thirty-eight patients diagnosed as
liver injury between 09/2003 and 08/2006 had been evaluated
prospectively in Al- Kindy Teaching Hospital.
A distinction was made between hemodynamically stable and
unstable patients. Different modalities of surgical procedures
were done concentrating on perihepatic gauze packing.
Results: (60 out of 138) patients included in the study were
clinically evaluated as hemodynamically stable. The average
abbreviated injury severity score (ISS) was 25. Twenty
patients underwent abdominal surgery. In 12 of them
In this study, the effects of blending the un-branched acrylate polymer known as Poly (n-decyl acrylate), and the branched acrylate polymer known as Poly (iso-octyl acrylate), on the viscosity index (VI), and the pour point of the Iraqi base stocks 40, and 60 respectively, were investigated. Toluene was used as a carrier solvent for both polymer types. The improvement level of oils (VI, & pour point) gained by blending the oil with the acrylate derived polymers was compared with the values of (VI, and pour point) gained by blending the oil with a commercial viscosity index, and pour point improver. The commercial lubricant additive was purchased and used by Al-Daura Refineries. It consisted of an un-known olefin copolymer dissolved i
... Show MoreAlthough the number of implants has increased gradually and consistently over the years to around one million per year globally, there is still far more potential for advancement in the field of dental implantology which is typically growing quickly. This study investigates the effect of nanofiller reinforcement high-performance polymer matrix to enhance mechanical and physical characteristics. Calcium silicate (CS)/Polyetherketoneketone (PEKK) biomedical composite (G0 as a control group) is reinforced with different weight percentages (G1-G4) of tellurium dioxide nanoparticles (TeO2NPs) ( n = 5). This research uses ethanol as a binder for mixing various weight percentages (wt%) of TeO2NPs w
... Show More