Background: Trigeminal neuralgia (TN), or Tic Douloureux, is one of the most common neuropathic pains. Gamma knife stereotactic radiosurgery (GNSRS) has been considered one of the procedures for treating primary TN. Objective: This study evaluates the effectiveness of GNSRS in treating primary TN in patients who are unresponsive to medical treatment in a single-center experience. Subjects and Methods: This study was conducted on 180 patients from January 2018 to October 2021. The study utilized the Barrow Neurological Institute (BNI) pain intensity score to assess pain before and after GNSRS treatment. Results: A total of 180 patients with primary TN were included in this study, 108 female with a 1.5:1 female: male ratio. Results showed significant pain score reduction post-GNSRS, indicating GNSRS as an effective second-line treatment for primary TN. The study suggests GNSRS's potential in decreasing medication dosage with minimal short-term complications, recommending further research to assess long-term benefits and side effects. A notable decrease in medication usage was reported, with minimal short-term complications. These results support the consideration of GNSRS as a viable alternative for TN patients who have exhausted traditional treatment options. Further research is recommended to explore long-term outcomes and potential side effects associated with GNSRS. Conclusion: The study's findings demonstrate that GNSRS is an effective and safe second-line treatment for patients with primary TN unresponsive to medical therapy. Significant reductions in pain intensity, as measured by the BNI pain scale, were observed following GNSRS treatment.
In this research, the concentration of radon gas was calculated in the book store rooms of schools in Diyala Governorate, it was calculated by Solid State Nuclear Track Detectors (SSNTDS) when the detector (CR-39) was used, the detector was placed and suspended at a distance of 160 cm from the surface of the earth, and the detector was exposed for 30 days to record alpha tracks. The results of radon concentration showed that the highest concentration percentage was found in (Eishtar) school, which was equal to (84.896) Bq/m3, while the lowest value was recorded in (Habhib) school, which was equal to (11.242) Bq/m3, where the concentration rate was equal to (28.158) Bq/m3. When we compared our results w
... Show MoreThe research is concerned about studying the absorption spectrum of the solution coumarin dye C47. The chloroform solvent was used with C47 dye in three different concentrations 10-4, 10-5 and 10-6 M. The laser dye solution was prepared by dissolving the required amount of dye in chloroform alcohol, while studying absorption spectrum before and after irradiation with gamma ray by cobalt-60 source 60Co at exposure time, which are 0, 4, 6 and 18 hours with different absorbed doses 0, 136, 204 and 612 Gy. The results show that red shift in the absorption spectrum was increased by increasing the concentration of laser dye solutions , while the increase of gamma dose led to increase the red shift after irradiation, as the exposure period and irr
... Show MoreIntroduction: Articaine was developed in 1969, with reported advantages which are increased potency, increased duration of its anesthetic effect and superior diffusion through bony tissue. The effectiveness of using 4% articaine infiltration for extraction of mandibular molar teeth in comparison to 2% lidocaine inferior alveolar nerve block is not settled yet. Aim: The aim of this study was to evaluate the effectiveness of using 4% articaine infiltration for extraction of mandibular molars by comparing it to the use of 2% lidocaine inferior alveolar nerve block in terms of success, the volume of local anesthetic agents and the pain experienced during the procedure. Materials and methods: A prospective randomized controlled study included
... Show MoreIn this study, dependence of gamma-ray absorption coefficient on the size of Pb particle size ranging from 200µm up to 2.5mm, using different weights of each particle size. The results show that gamma-ray attenuation coefficient is inversely proportional with the size of Pb particle size due to the reduction of the spaces between the lead particles.
The method of measurement dosimetry in neutron – gamma field by using CaSo4 : Dy (PTFE) disc which has a diameter of 1.3mm and thickness of 0.2mm and using hydrogenated material as a converters of neutron to recoil protons (n-p) reaction, the discs were irradiated by neutron source (241Am-Be) with flux of 4.5?105 n/cm2s for different time to obtain different dose. The TL signals, which we have been obtained by using the converters, are increases to 71%. So we can resolve the neutron and gamma in mixed field.
The researchers aim of this research to analyze the reality of educational services in the city of Ramadi in order to reveal the efficiency of the spatial distribution of schools at the level of residential neighborhoods and the requirements of the population, based on the standards and indicators for this service.
The research problem related to the educational function of the city of Ramadi was formulated by asking about the efficiency of the spatial distribution of educational services and whether there is a balance in the distribution of schools to residential neighborhoods in a way that meets the requirements of the population, and in order to answer the research problem, the research hypothesis was formulated that there is
... Show MoreThe effect of 0.662MeV gamma radiation on the optical properties of the CdTe thin films was studied. 300nm thickness of CdTe samples were irradiated with doses (10, 20, 30,60krad) in room temperature. The absorption spectra for all the samples were recorded using UV- Visible spectrometer in order to calculate the energy gap, width of localized states and optical constants(refractive index, extinction coefficient, real and imaginary parts of dielectric constant). The optical energy gap was found to decrease from (1.53 to 1.48 eV), while the width of localized states increased from (1.34 to 1.49 eV) with the increasing of radiation dose. The behavior of energy gap with the irradiation dose makes the material a good candidate for dosimetry
... Show MoreThe use of non-parametric models and subsequent estimation methods requires that many of the initial conditions that must be met to represent those models of society under study are appropriate, prompting researchers to look for more flexible models, which are represented by non-parametric models
In this study, the most important and most widespread estimations of the estimation of the nonlinear regression function were investigated using Nadaraya-Watson and Regression Local Ploynomial, which are one of the types of non-linear
... Show MoreLevels of primary education are varying in Sulaimaniyah Province, which defines as a lower stage of education process and seems to be found in most settlements to save the individual and community from illiteracy in its traditional notion which means the individuals, potentiality for reading and writing if he/she graduated from this stage successfully. The research can put the priority for goodness of primary education service within Sulaimaniyah Province that includes Sulaimaniyah city as a dominance based on statistical indicator which called the standardized score (z). The indicator (z) calculated for the basic items of primary education to diagnosis the range of developing that service in Sulaimaniyah city especially and put
... Show MoreNano gamma alumina was prepared by double hydrolysis process using aluminum nitrate nano hydrate and sodium aluminate as an aluminum source, hydroxyle poly acid and CTAB (cetyltrimethylammonium bromide) as templates. Different crystallization temperatures (120, 140, 160, and 180) 0C and calcinations temperatures (500, 550, 600, and 650) 0C were applied. All the batches were prepared at PH equals to 9. XRD diffraction technique and infrared Fourier transform spectroscopy were used to investigate the phase formation and the optical properties of the nano gamma alumina. N2 adsorption-desorption (BET) was used to measure the surface area and pore volume of the prepared nano alumina, the particle size and the
... Show More