Most studies on deep beams have been made with reinforced concrete deep beams, only a few studies investigate the response of prestressed deep beams, while, to the best of our knowledge, there is not a study that investigates the response of full scale (T-section) prestressed deep beams with large web openings. An experimental and numerical study was conducted in order to investigate the shear strength of ordinary reinforced and partially prestressed full scale (T-section) deep beams that contain large web openings in order to investigate the prestressing existence effects on the deep beam responses and to better understand the effects of prestressing locations and opening depth to beam depth ratio on the deep beam performance and behavior. A total of seven deep beam specimens with identical shear span-to-depth ratio, compressive strength of concrete, and amount of horizontal and vertical web reinforcement ratios have been tested under mid-span concentrated load applied monotonically until failure. The main variables studied were the effects of depth of the web openings and the prestressing location on deep beam performance. The test results showed that the enlargement in the size of web openings substantially reduces the element’s shear capacities while prestressing strands location above the web openings has more effect at increasing the element’s shear capacities. The numerical study considered three-dimensional finite element models that have been developed in Abaqus software to simulate and predict the performance of prestressed deep beams. The results of numerical simulations were in good agreement with the experimental ones.
The process of capital investment appraisal takes hold the attention of managers and accountants of the industrial companies. This process involves the use of multiple and diverse financial evaluation methods to measure the economic attractiveness of capital investment peojects. This multiplicity and diversity of financial evaluation metods have been the motive of this research to: investigate some organizational variables such as the desired objectives, identify managerial procedures which regulate the capital investment process, specify evaluation methods and examine the relationships between these variables and evaluation methods actually used by a sample of public industrial companies in Jordan.
The data wa
... Show MoreThe aim of the research is to identify the extent of the ability to ensure the integrated reports by the auditor in verifying the credibility of these reports, and their implications for the benefit of all parties dealing with the economic unit, as well as measuring the impact of the assurance procedures followed by the auditors and their role in confirming these reports.
The research methodology was designed after studying the previous literature related to the research variables, and then the relationship between these variables was tested, through the use of a questionnaire list. A questionnaire targeting the community of auditors in the local environment, and the results of the study wer
... Show MoreABSTRACT Background:Hydrogen absorption and related degradation in the mechanical properties of Ni-Ti based orthodontic wires has been demonstrated following exposure to fluoride prophylactic agents. This study was designed to investigate the effects of three fluoride containing agents on the load deflection characteristics of heat activated nickel titanium arch wires during unloading phase. Material and method: Eighty specimens of heat activated nickel titanium arch wires were obtained from Ortho Technology Company, half of which had a 0.016 inch round and 0.019x0.025 rectangular. Ten specimens from both wire size were immersed in one of the tested fluoride prophylactic agents (neutral sodium fluoride gel, stannous fluoride gel or phos-flu
... Show MoreResin-modified glass ionomer cement tends to shrink due to polymerization of the resin component. Additionally, they are more prone to syneresis and imbibition during the setting process. This
Different parameters of double pipe helical coil were investigation experimentally. Four coils were used; three with a curvature ratio (0.037, 0.031, and 0.028) and 11mm diameter of the inner tube while the fourth with 0.033 curvature ratio and 13 mm diameter of the inner tube. The hot water flow in the inner tube whereas the cold water flows in the annulus. The inlet temperatures of hot and cold water are 50 0C and 18 0C respectively. The inner mass flow rate ranges from 0.0167 to 0.0583 kg/s. The results show the Nusselt number increase with increase curvature ratio. The Nusselt number of the coil with 0.037 curvature ratio increases by approximately 12.3 % as compare with 0.028 curvature ratio. The results also r
... Show MoreThe present study illustrates observations, record accurate description and discussion about the behavior of twelve tested, simply supported, precast, prestressed, segmental, concrete beams with different segment numbers exposed to high fire temperatures of 300°C, 500°C, and 700°C. The test program included thermal tests by using a furnace manufactured for this purpose to expose to high burning temperature (fire flame) nine beams which were loaded with sustaining dead load throughout the burning process. The beams were divided into three groups depending on the precast segments number. All had an identical total length of 3150mm but each had different segment number (9, 7, and 5 segments), in other words, different segment length
... Show More