Preferred Language
Articles
/
fxiWlJQBVTCNdQwCLh2y
Accuracy of Gingival Crevicular Fluid Biomarkers of MMP8, TIMP1, RANK, RANKL, and OPG in Differentiating Symptomatic and Asymptomatic Apical Periodontitis
...Show More Authors

Apical periodontitis (AP) is the most prevalent chronic inflammatory disease of the teeth. Bone resorption dynamics in symptomatic and asymptomatic AP are still unrecognized. This study examined different inflammatory markers within gingival crevicular fluid, including matrix metalloproteinases 8 (MMP8), tissue inhibitors of metalloproteinases 1 (TIMP1), receptor activator of nuclear factor κB (RANK), its ligand (RANKL), and osteoprotegerin (OPG), to be used in comparing symptomatic apical periodontitis (SAP) and asymptomatic apical periodontitis (AAP) versus healthy teeth. Subjects with SAP, AAP, and a control group were recruited and GCF samples were collected by Periopaper strips. Clinical and radiographical measures were used for diagnosing AP. Levels of MMP8, TIMP, RANK, RANKL, and OPG were determined by ELISA and their abilities to discriminate between examined sites were evaluated by receiver operator characteristic (ROC) curves. All examined biomarkers were statistically significant higher (p < 0.05) in SAP than AAP and the control group, apart from RANK. Significant positive correlations (p < 0.05) were identified between all SAP and AAP biomarkers except TIMP1 and RANK in AAP teeth. TIMP1 and OPG exhibited the highest ability to distinguish between SAP and AAP with areas under the curve of 0.824 and 0.763 in comparing SAP and the control group, and 0.732 and 0.73 when comparing AAP and the control group, respectively. Additionally, TIMP1 and OPG showed the highest AUC of 0.778 and 0.747 when SAP and AAP were compared, respectively. This study concluded that GCF levels of TIMP1 and OPG can be used to differentiate between SAP, AAP, and healthy teeth.

Scopus Clarivate Crossref
View Publication
Publication Date
Sat Sep 01 2007
Journal Name
Al-khwarizmi Engineering Journal
Free Convective Heat Transfer with Different Sections Lengths Placed at the Exit of a Vertical Circular Tube subjected to a Constant Heat Flux
...Show More Authors

A free convective heat transfer from the inside surface of a uniformly heated vertical circular tube has been experimentally investigated under a constant wall heat flux boundary condition for laminar air flow in the ranges of RaL from 6.9108 to 5109. The effect of the different sections (restrictions) lengths placed at the exit of the heated tube on the surface temperature distribution, the local and average heat transfer coefficients were examined. The experimental apparatus consists of aluminum circular tube with 900 mm length and 30 mm inside diameter (L/D=30). The exit sections (restrictions) were included circular tubes having the same inside diameter as the heated tube but with different lengths of

... Show More
View Publication Preview PDF
Publication Date
Wed Feb 27 2019
Journal Name
Journal Of Nano Research
A Specific NH&lt;sub&gt;3&lt;/sub&gt; Gas Sensor of a Thick MWCNTs-OH Network for Detection at Room Temperature
...Show More Authors

NH3 gas sensor was fabricated based on deposited of Functionalized Multi-Walled Carbon Nanotubes (MWCNTs-OH) suspension on filter paper substrates using suspension filtration method. The structural, morphological and optical properties of the MWCNTs film were characterized by XRD, AFM and FTIR techniques. XRD measurement confirmed that the structure of MWCNTs is not affected by the preparation method. The AFM images reflected highly ordered network in the form of a mat. The functional groups and types of bonding have appeared in the FTIR spectra. The fingerprint (C-C stretch) of MWCNTs appears in 1365 cm-1, and the backbone of CNTs observed at 1645 cm-1. A homemade sensi

... Show More
View Publication
Scopus (16)
Crossref (16)
Scopus Clarivate Crossref
Publication Date
Sun Mar 01 2020
Journal Name
Journal Of Colloid Interface Science
Corrigendum to “Organic acid concentration thresholds for ageing of carbonate minerals: Implications for CO2 trapping/storage” [J. Colloid Interface Sci. 534 (2019) 88–94]
...Show More Authors

Erratum for Organic acid concentration thresholds for ageing of carbonate minerals: Implications for CO2 trapping/storage.

Scopus Clarivate Crossref
Publication Date
Sat Mar 30 2019
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Removal of Manganese Ions (Mn2+) from a Simulated Wastewater by Electrocoagulation/ Electroflotation Technologies with Stainless Steel Mesh Electrodes: Process Optimization Based on Taguchi Approach
...Show More Authors

This study depicts the removal of Manganese ions (Mn2+) from simulated wastewater by combined electrocoagulation/ electroflotation technologies. The effects of initial Mn concentration, current density (C.D.), electrolysis time, and different mesh numbers of stainless steel screen electrodes were investigated in a batch cell by adopting Taguchi experimental design to explore the optimum conditions for maximum removal efficiency of Mn. The results of multiple regression and signal to noise ratio (S/N) showed that the optimum conditions were Mn initial concentration of 100 ppm, C.D. of 4 mA/cm2, time of 120 min, and mesh no. of 30 (wire/inch). Also, the relative significance of each factor was attained by the analysis

... Show More
View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Sat Mar 30 2019
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Removal of Manganese Ions (Mn2+) from a Simulated Wastewater by Electrocoagulation/ Electroflotation Technologies with Stainless Steel Mesh Electrodes: Process Optimization Based on Taguchi Approach
...Show More Authors

This study depicts the removal of Manganese ions (Mn2+) from simulated wastewater by combined electrocoagulation/ electroflotation technologies. The effects of initial Mn concentration, current density (C.D.), electrolysis time, and different mesh numbers of stainless steel screen electrodes were investigated in a batch cell by adopting Taguchi experimental design to explore the optimum conditions for maximum removal efficiency of Mn. The results of multiple regression and signal to noise ratio (S/N) showed that the optimum conditions were Mn initial concentration of 100 ppm, C.D. of 4 mA/cm2, time of 120 min, and mesh no. of 30 (wire/inch). Also, the relative significance of each factor was attained by the analysis of variance (ANO

... Show More
View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Thu Jun 06 2013
Journal Name
Advances In Physics Theories And Applications
Adsorption study of Symmetrical schiff base ligand 4,4 -[hydrazine -1,2- diylidenebis ( methan-1-yl-1-ylidene) bis ( 2-methoxyphenol)] on Granulated Initiated calcined Iraqi …
...Show More Authors

Publication Date
Mon Mar 18 2019
Journal Name
Baghdad Science Journal
Enhancement of hydrothermally Co <sub>3</sub> O <sub>4</sub> thin films as H <sub>2</sub> S gas sensor by loading yttrium element
...Show More Authors

The gas sensing properties of Co3O4and Co3O4:Y nano structures were investigated. The films were synthesized using the hydrothermal method on a seeded layer. The XRD, SEM analysis and gas sensing properties were investigated for Co3O4and Co3O4:Y thin films. XRD analysis shows that all films are polycrystalline in nature, having a cubic structure, and the crystallite size is (11.7)nm for cobalt oxide and (9.3)nm for the Co3O4:10%Y. The SEM analysis of thin films obviously indicates that Co3O4possesses a nanosphere-like structure and a flower-like structure for Co3O4:Y.The sensitivity, response time and recovery time to a H2S reducing gas were tested at different operating

... Show More
Publication Date
Fri Jan 01 2021
Journal Name
Annals Of Tropical Medicine & Public Health
Newly developed method for determination of methyldopa drug using ammonium ceric (IV) nitrate by continuous flow injection analysis via homemade NAG-ADF-300-2 analyser
...Show More Authors

A new, simple, sensitive and fast developed method was used for the determination of methyldopa in pure and pharmaceutical formulations by using continuous flow injection analysis. This method is based on formation a burgundy color complex between methyldopa andammonium ceric (IV) nitrate in aqueous medium using long distance chasing photometer NAG-ADF-300-2. The linear range for calibration graph was 0.05-8.3 mmol/L for cell A and 0.1-8.5 mmol/L for cell B, and LOD 952.8000 ng /200 µL for cell A and 3.3348 µg /200 µL for cell B respectively with correlation coefficient (r) 0.9994 for cell A and 0.9991 for cell B, RSD % was lower than 1 % for n=8. The results were compared with classical method UV-Spectrophotometric at λ max=280 n

... Show More
Crossref (2)
Crossref
Publication Date
Wed Jan 01 2014
Journal Name
Journal Of The College Of Languages (jcl)
COMENTARIO ESTILÍSTICO- LITERARIO DE UN CUENTO DE JOSÉ ANTONIO GRILLO LONGORIA: “EL ALACRÁN Stylistic -Literary analysis of the story Jose Antonio Grillo Longoria: "The Scorpio"
...Show More Authors
 
 
Al  comentar un texto literario no se llega solamente mediante el estudio de su Historia. Ese estudio sería vano, se convertiría en una simple memorización de datos, creo yo.
Comentar un texto supone comprobar las características generales de un movimiento, estilo de un autor... en otras palabras comprender con profundidad el texto literario en s
... Show More
View Publication Preview PDF
Publication Date
Sat Dec 30 2023
Journal Name
Basrah Journal Of Surgery
Can Hyaluronic acid gel enhance wound healing faster than Advanced Platelets Rich Fibrin following surgical removal of impacted mandibular third molars? A Randomized Controlled Trial
...Show More Authors

View Publication Preview PDF
Crossref