Data steganography is a technique used to hide data, secret message, within another data, cover carrier. It is considered as a part of information security. Audio steganography is a type of data steganography, where the secret message is hidden in audio carrier. This paper proposes an efficient audio steganography method that uses LSB technique. The proposed method enhances steganography performance by exploiting all carrier samples and balancing between hiding capacity and distortion ratio. It suggests an adaptive number of hiding bits for each audio sample depending on the secret message size, the cover carrier size, and the signal to noise ratio (SNR). Comparison results show that the proposed method outperforms state of the art methods in terms of average segmental SNR, number of failing samples, and Czekanowski Distance (CZD). In addition, the proposed method shows the ability to operate with large message sizes (up to half of carrier size) with graceful degradation as opposed to the other methods which fail at large message size. So, the proposed method provides more flexibility in message and carrier sizes while preserving high efficiency.
Background: As a multifactorial disorder, temporomandibular joint (TMD) is difficult to diagnose, and multiple factors affect the joint and cause the temporomandibular disorder. Standardization of clinical diagnosis of TMD should be used to reach a definite clinical diagnosis; the condylar bone may degenerate in accordance with these disorders. Aims: Evaluate the correlation between the clinical diagnosis and degenerative condylar change (flattening, sclerosis, erosion, and osteophyte). Materials and Methods: A prospective study with a study group of 97 TMD patients (total of 194 joints) aged 20 to 50. Patients were sent to cone beam computed tomography (CBCT) to assess the degenerative condylar change. Results: No association was found bet
... Show MoreIn this study, structures damage identification method based on changes in the dynamic characteristics
(frequencies) of the structure are examined, stiffness as well as mass matrices of the curved
(in and out-of-plane vibration) beam elements is formulated using Hamilton's principle. Each node
of both of them possesses seven degrees of freedom including the warping degree of freedom. The
curved beam element had been derived based on the Kang and Yoo’s thin-walled curved beam theory
in 1994. A computer program was developing to carry out free vibration analyses of the curved
beam as well as straight beam. Comparing with the frequencies for other researchers using the general
purpose program MATLAB. Fuzzy logic syste
Immunization is one of the most cost-effective and successful public health applications. The results of immunization are difficult to see as the incidence of disease occurrence is low while adverse effects following the immunization are noticeable, particularly if the vaccine was given to apparently healthy person. High safety expectations of population regarding the vaccines so they are more prone to hesitancy regarding presence of even small risk of adverse events which may lead to loss of pub
... Show MoreBotnet is a malicious activity that tries to disrupt traffic of service in a server or network and causes great harm to the network. In modern years, Botnets became one of the threads that constantly evolving. IDS (intrusion detection system) is one type of solutions used to detect anomalies of networks and played an increasing role in the computer security and information systems. It follows different events in computer to decide to occur an intrusion or not, and it used to build a strategic decision for security purposes. The current paper
This study compared in vitro the microleakage of a new low shrink silorane-based posterior composite (Filtek™ P90) and two methacrylate-based composites: a packable posterior composite (Filtek™ P60) and a nanofill composite (Filtek™ Supreme XT) through dye penetration test. Thirty sound human upper premolars were used in this study. Standardized class V cavities were prepared at the buccal surface of each tooth. The teeth were then divided into three groups of ten teeth each: (Group 1: restored with Filtek™ P90, Group 2: restored with Filtek™ P60, and Group 3: restored with Filtek™ Supreme XT). Each composite system was used according to the manufacturer's instructions with their corresponding adhesive systems. The teeth were th
... Show MoreIn the present work, a d.c. magnetron sputtering system was designed and fabricated. The chamber of this system was includes from two copper coaxial cylinders where the inner one used as a cathode (target) while the outer one used as the anode with Solenoid magnetic coil located on the outer cylinder (anode). The axial profile of magnetic field for various coil current (from 2A to 14 A) are shown. The plasma characteristics in the normal glow discharge region are diagnostics by the 2.2mm diameter Langmuir probe with different length along the cathode and located at different radial positions 1cm and 2cm from the cathode surface. The result of this work shows that, the electron energy distributions at different radial positions along the
... Show More