Pick and place system is one of the significant employments of modern robots utilized in industrial environments. The objective of this research is to make a comparison of time sequences by combining multiple axes of sequences. A pick-place system implemented with pneumatic linear double-acting cylinders to applicator in automated systems processes for manufacturing. The challenge of 3-axes movement control was achieved using the PLC (Programmable Logic Controller) controller such that the merging between two or three axes was achieved according to the selected sequence of the program. The outcomes show the contrasted sequences and the reference in a constant velocity. The main variable parameter is the number of steps for each sequence. The combination of two axes has developed the sequence and reduced in number of sequences for a path. At last, one of the important factors in moving products industry is the smooth product’s movement, because any high speed might cause a vibration in the system and lead to a decreased positioning accuracy.
For this research, the utilisation of electrocoagulation (EC) toremove theciprofloxacin (CIP) and levofloxacin (LVX) from aqueous solutions was examined. The effective removal efficiencies are 93.47% for CIP and 88.00% for LVX, under optimum conditions. The adsorption isotherm models with suitable mechanisms were applied to determine the elimination of CIP and LVX utilizingtheEC method. Thefindingsshowed the adsorption of CIP and LVX on iron hydroxide flocs followed the Sips isotherm, with correlation coefficient values (R2) of 0.939 and 0.937. Threekinetic models were reviewed to determine the accurate CIP and LVX elimination methods using the EC method. The results showed that itfittedfor the second-order model, which indicated that the c
... Show MoreIt is important that real time stability in smart grids is ensured as the integration of renewables and the complexity of the systems grows. In this paper, we provide a solid architecture, which combines a Residual CNNLSTM deep neural network predictor, FPGA-accelerated Model Predictive Control (MPC), and SHAP-based explainability. The proposed method predicted with 99.8% accuracy using the Electrical grid Stability Simulated Dataset (UCI) and minimized the instability rates surpassing 85 percent in all operating conditions. Meeting real-time operating needs, FPGA deployment on a Xilinx Zynq UltraScale+ provided 3.1 ms latency and 5 times reduced energy consumption against CPU processing. By emphasizing bus voltage and frequency as major in
... Show MoreFor this research, the utilisation of electrocoagulation (EC) toremove theciprofloxacin (CIP) and levofloxacin (LVX) from aqueous solutions was examined. The effective removal efficiencies are 93.47% for CIP and 88.00% for LVX, under optimum conditions. The adsorption isotherm models with suitable mechanisms were applied to determine the elimination of CIP and LVX utilizingtheEC method. Thefindingsshowed the adsorption of CIP and LVX on iron hydroxide flocs followed the Sips isotherm, with correlation coefficient values (R2) of 0.939 and 0.937. Threekinetic models were reviewed to determine the accurate CIP and LVX elimination methods using the EC method. The results showed that itfittedfor the second-order model, which indicated that the c
... Show MoreInternal control is system,defined and implemented under its responsibility , which aims to ensure that; laws and regulations are complied with; the instructions and directional guidelines fixed by Executive Management or the Management Borad are applied; the company internal processes are functioning correctlly , particularly those implicating the security of its assets; Financial Information is reliable; and generally contributes to the control over its activities , to the efficiency of its operation and to the efficient utilisation of its Resources. By helping to anticipate and control the risks involved in not meeting the objectives the company has set for itself, the internal control system plays akey role in conducting & monito
... Show MoreThis paper presents the implementation of a complex fractional order proportional integral derivative (CPID) and a real fractional order PID (RPID) controllers. The analysis and design of both controllers were carried out in a previous work done by the author, where the design specifications were classified into easy (case 1) and hard (case 2) design specifications. The main contribution of this paper is combining CRONE approximation and linear phase CRONE approximation to implement the CPID controller. The designed controllers-RPID and CPID-are implemented to control flowing water with low pressure circuit, which is a first order plus dead time system. Simulation results demonstrate that while the implemented RPID controller fails to stabi
... Show MoreThe solidification process in a multi-tube latent heat energy system is affected by the natural convection and the arrangement of heat exchanger tubes, which changes the buoyancy effect as well. In the current work, the effect of the arrangement of the tubes in a multi-tube heat exchanger was examined during the solidification process with the focus on the natural convection effects inside the phase change material (PCM). The behavior of the system was numerically analyzed using liquid fraction and energy released, as well as temperature, velocity and streamline profiles for different studied cases. The arrangement of the tubes, considering seven pipes in the symmetrical condition, are assumed at different positions in the system, i
... Show MoreThe aim of this research is to measure and analyze the gap between the actual reality and the requirements of the environmental management system in the middle refineries company/refinery cycle according to ISO14001: 2015, as well as to measure the availability of a clean production strategy and test the relationship and impact between the availability of the requirements of the standard and a clean production strategy for the actual reality in the company.
The research problem was determined by the extent to which the requirements of the environmental management system are applied according to ISO14001: 2015 in the middle refineries company? To what extent are the required clean production strategies ava
... Show MoreThe present study aims to present a proposed realistic and comprehensive cyber strategy for the Communications Directorate for the next five years (2022-2026) based on the extent of application and documentation of cybersecurity measures in the Directorate and the scientific bases formulating the strategy. The present study is significant in that it provides an accurate diagnosis of the capabilities of the cyber directorate in terms of strengths and weaknesses in its internal environment and the opportunities and threats that surround it in the external environment, based on the results of the assessment of the reality of cybersecurity according to the global Cybersecurity index, which provides a strong basis for building its strategic dire
... Show More