Preferred Language
Articles
/
fxbK1okBVTCNdQwCIo3E
Comparison Sequences of Pick and Place System Controlled Using PLC
...Show More Authors

Pick and place system is one of the significant employments of modern robots utilized in industrial environments. The objective of this research is to make a comparison of time sequences by combining multiple axes of sequences. A pick-place system implemented with pneumatic linear double-acting cylinders to applicator in automated systems processes for manufacturing. The challenge of 3-axes movement control was achieved using the PLC (Programmable Logic Controller) controller such that the merging between two or three axes was achieved according to the selected sequence of the program. The outcomes show the contrasted sequences and the reference in a constant velocity. The main variable parameter is the number of steps for each sequence. The combination of two axes has developed the sequence and reduced in number of sequences for a path. At last, one of the important factors in moving products industry is the smooth product’s movement, because any high speed might cause a vibration in the system and lead to a decreased positioning accuracy.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Apr 23 2021
Journal Name
International Journal Of Environmental Analytical Chemistry
Removal of levofloxacin and ciprofloxacin from aqueous solutions and an economic evaluation using the electrocoagulation process‏
...Show More Authors

For this research, the utilisation of electrocoagulation (EC) toremove theciprofloxacin (CIP) and levofloxacin (LVX) from aqueous solutions was examined. The effective removal efficiencies are 93.47% for CIP and 88.00% for LVX, under optimum conditions. The adsorption isotherm models with suitable mechanisms were applied to determine the elimination of CIP and LVX utilizingtheEC method. Thefindingsshowed the adsorption of CIP and LVX on iron hydroxide flocs followed the Sips isotherm, with correlation coefficient values (R2) of 0.939 and 0.937. Threekinetic models were reviewed to determine the accurate CIP and LVX elimination methods using the EC method. The results showed that itfittedfor the second-order model, which indicated that the c

... Show More
Scopus (63)
Crossref (44)
Scopus Clarivate Crossref
Publication Date
Tue Dec 16 2025
Journal Name
Radioelectronics. Nanosystems. Information Technologies.
Intelligent Control and Stability Analysis of Smart Grids Using CNN-LSTM Network and Model Predictive Controller
...Show More Authors

It is important that real time stability in smart grids is ensured as the integration of renewables and the complexity of the systems grows. In this paper, we provide a solid architecture, which combines a Residual CNNLSTM deep neural network predictor, FPGA-accelerated Model Predictive Control (MPC), and SHAP-based explainability. The proposed method predicted with 99.8% accuracy using the Electrical grid Stability Simulated Dataset (UCI) and minimized the instability rates surpassing 85 percent in all operating conditions. Meeting real-time operating needs, FPGA deployment on a Xilinx Zynq UltraScale+ provided 3.1 ms latency and 5 times reduced energy consumption against CPU processing. By emphasizing bus voltage and frequency as major in

... Show More
View Publication Preview PDF
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Fri Apr 23 2021
Journal Name
International Journal Of Environmental Analytical Chemistry
Removal of levofloxacin and ciprofloxacin from aqueous solutions and an economic evaluation using the electrocoagulation process‏
...Show More Authors

For this research, the utilisation of electrocoagulation (EC) toremove theciprofloxacin (CIP) and levofloxacin (LVX) from aqueous solutions was examined. The effective removal efficiencies are 93.47% for CIP and 88.00% for LVX, under optimum conditions. The adsorption isotherm models with suitable mechanisms were applied to determine the elimination of CIP and LVX utilizingtheEC method. Thefindingsshowed the adsorption of CIP and LVX on iron hydroxide flocs followed the Sips isotherm, with correlation coefficient values (R2) of 0.939 and 0.937. Threekinetic models were reviewed to determine the accurate CIP and LVX elimination methods using the EC method. The results showed that itfittedfor the second-order model, which indicated that the c

... Show More
Crossref (44)
Crossref
Publication Date
Tue Dec 01 2009
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
The Role of Internal Contrl in Electronic Accounting Information System: Applied Study in Spacimen from Kurdistan Regin Iraq
...Show More Authors

Internal control is system,defined and implemented under its responsibility , which aims to ensure that; laws and regulations are complied with; the instructions and directional guidelines fixed by Executive Management or the Management Borad are applied; the company internal processes are functioning correctlly , particularly those implicating the security of its assets; Financial Information is reliable; and generally contributes to the control over its activities , to the efficiency of its operation and to the efficient utilisation of its Resources. By helping to anticipate and control the risks involved in not meeting the objectives the company has set for itself, the internal control system plays akey role in conducting & monito

... Show More
View Publication Preview PDF
Publication Date
Thu Sep 01 2022
Journal Name
Iaes International Journal Of Robotics And Automation
Implementation of a complex fractional order proportional-integral-derivative controller for a first order plus dead time system
...Show More Authors

This paper presents the implementation of a complex fractional order proportional integral derivative (CPID) and a real fractional order PID (RPID) controllers. The analysis and design of both controllers were carried out in a previous work done by the author, where the design specifications were classified into easy (case 1) and hard (case 2) design specifications. The main contribution of this paper is combining CRONE approximation and linear phase CRONE approximation to implement the CPID controller. The designed controllers-RPID and CPID-are implemented to control flowing water with low pressure circuit, which is a first order plus dead time system. Simulation results demonstrate that while the implemented RPID controller fails to stabi

... Show More
Publication Date
Fri Jan 01 2021
Journal Name
Microchemical Journal
A flow analysis system integrating an optoelectronic detector for the quantitative determination of active ingredients in pharmaceutical formulations
...Show More Authors

View Publication Preview PDF
Scopus (24)
Crossref (17)
Scopus Clarivate Crossref
Publication Date
Tue Nov 09 2021
Journal Name
Energies
Natural Convection Effect on Solidification Enhancement in a Multi-Tube Latent Heat Storage System: Effect of Tubes’ Arrangement
...Show More Authors

The solidification process in a multi-tube latent heat energy system is affected by the natural convection and the arrangement of heat exchanger tubes, which changes the buoyancy effect as well. In the current work, the effect of the arrangement of the tubes in a multi-tube heat exchanger was examined during the solidification process with the focus on the natural convection effects inside the phase change material (PCM). The behavior of the system was numerically analyzed using liquid fraction and energy released, as well as temperature, velocity and streamline profiles for different studied cases. The arrangement of the tubes, considering seven pipes in the symmetrical condition, are assumed at different positions in the system, i

... Show More
View Publication
Scopus (22)
Crossref (23)
Scopus Clarivate Crossref
Publication Date
Sun Aug 30 2020
Journal Name
Journal Of Economics And Administrative Sciences
The effect of the environmental management system on the clean production strategy / case study in Middle Refineries Company
...Show More Authors

The aim of this research is to measure and analyze the gap between the actual reality and the requirements of the environmental management system in the middle refineries company/refinery cycle according to ISO14001: 2015, as well as to measure the availability of a clean production strategy and test the relationship and impact between the availability of the requirements of the standard and a clean production strategy for the actual reality in the company.

The research problem was determined by the extent to which the requirements of the environmental management system are applied according to ISO14001: 2015 in the middle refineries company? To what extent are the required clean production strategies ava

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Dec 28 2016
Journal Name
Environmental Technology
Remediation of groundwater contaminated with the lead–phenol binary system by granular dead anaerobic sludge-permeable reactive barrier
...Show More Authors

Scopus (21)
Crossref (20)
Scopus Clarivate Crossref
Publication Date
Sun Nov 07 2021
Journal Name
Review Of International Geographical Education Online
Requirements of Formulating a National Strategy for Developing the Cybersecurity System in Iraq According to GCI.v4(2019) Index
...Show More Authors

The present study aims to present a proposed realistic and comprehensive cyber strategy for the Communications Directorate for the next five years (2022-2026) based on the extent of application and documentation of cybersecurity measures in the Directorate and the scientific bases formulating the strategy. The present study is significant in that it provides an accurate diagnosis of the capabilities of the cyber directorate in terms of strengths and weaknesses in its internal environment and the opportunities and threats that surround it in the external environment, based on the results of the assessment of the reality of cybersecurity according to the global Cybersecurity index, which provides a strong basis for building its strategic dire

... Show More
Preview PDF
Scopus (4)
Scopus