Preferred Language
Articles
/
fhiLZ5UBVTCNdQwCbS0l
Pulse transmission time and amplitude of digital pulse wave determined by fingertip plethysmography as a surrogate marker of brachial artery flowmediated dilatation
...Show More Authors

Objectives: To assess the changes in blood vessel stiffness and digital pulse wave amplitude because of flowmediateddilatation, and to explore how these two variables change when endothelial dysfunction isexperimentally induced.Method: The experimental study was conducted at the departments of physiology at the College of Medicine,Mustansiriyah University, and the College of Medicine, Al-Iraqia University, Baghdad, Iraq, from October 14, 2021, toMay 31, 2022, and comprised healthy young males who were subjected to the flow-mediated dilatation techniqueon the left brachial artery. Pulse transit time and the amplitude of the digital pulse wave were measured duringreactive hyperaemia for 2.5 minutes from the left middle finger using a piezoelectric pressure sensor and asimultaneous Lead I electrocardiogram. Endothelial dysfunction (ED) was induced by oscillatory and retrogradeshear rates. The correlation between variables was calculated in Excel running on the Windows operating system.Results: There were 10 second-year medical students with mean age 22±0 years and mean body mass index25.7±4.8kg/m2. During reactive hyperaemia, pulse transit time was significantly increased by 3-5% in both normalendothelium and experimentally induced endothelial dysfunction relative to the pre-occluded artery, and thedifference was not significant (p>0.05). Digital pulse wave amplitude increased significantly in normal endotheliumrelative to the pre-occluded artery (p<0.05), but not in experimentally-induced endothelial dysfunction (p>0.05).Conclusion: The pulse transit time and digital pulse wave amplitudes of the photo plethysmography signal may beused to detect changes in vessel wall diameter and tone throughout the reactive hyperaemia process. Digital pulsewave amplitude was better able to detect experimentally-induced endothelial dysfunction, as assessed by the flowmediateddilatation protocol, than pulse transit time.Key Words: Hyperemia, Brachial Artery, Dilatation, Plethysmography, Electrocardiography, Pulse Wave,Endothelium, Running

Scopus Clarivate Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Oct 01 2022
Journal Name
Journal Of Pakistan Association Of Dermatologists
Zinc as an essential element for normal immune reactions and as a therapeutic agent for autoimmune diseases
...Show More Authors

Scopus (1)
Scopus
Publication Date
Fri Feb 08 2019
Journal Name
Journal Of The College Of Education For Women
Evaluation Tv- Image Quality for Different Cable Signal Transmission Resistance Based on Contrast Edge Algorithm
...Show More Authors

Some degree of noise is always present in any electronic device that
transmits or receives a signal . For televisions, this signal i has been to s the
broadcast data transmitted over cable-or received at the antenna; for digital
cameras, the signal is the light which hits the camera sensor. At any case, noise
is unavoidable. In this paper, an electronic noise has been generate on
TV-satellite images by using variable resistors connected to the transmitting cable
. The contrast of edges has been determined. This method has been applied by
capturing images from TV-satellite images (Al-arabiya channel) channel with
different resistors. The results show that when increasing resistance always
produced higher noise f

... Show More
View Publication Preview PDF
Publication Date
Sun Mar 10 2024
Journal Name
Journal Of Optics
Optical signal transmission for the visible light communication system through the water–air interface link
...Show More Authors

View Publication
Scopus (4)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Sun May 30 2021
Journal Name
Indian Journal Of Forensic Medicine & Toxicology,
Effect of Diabetes and Hypertension on Right Carotid Artery Intima Media Thickness and Variable Spectral Waveform Indices And Parameters in Relation To Age for Iraqi Patients
...Show More Authors

Background: Arterial stiffness is related with atherosclerosis and cardiovascular disease events. Patients with atherosclerotic disease show to have larger diameters, reduced arterial compliance and lower flow velocities. Aim of study : To compare between patients of two age groups with concomitant diseases diabetes and hypertension in regard to intima media thickness and blood flow characteristics in order to estimate the blood perfusion to the brain via the common and internal carotid arteries. Subject and Methods : 40 patients with (diabetic and hypertension) diseases were enrolled , they were classified according to age. Color Doppler and B mode ultrasound was used to determine lumen Diameter (D), Intima – media thickness (IMT)

... Show More
Scopus (1)
Scopus
Publication Date
Thu Dec 29 2022
Journal Name
Arterial Hypertension
Correlation between coronary artery calcium score and aorta diameter in population with long-standing hypertension using noncontrast CT scan
...Show More Authors

View Publication
Scopus Clarivate Crossref
Publication Date
Tue Sep 15 2020
Journal Name
Al-academy
Aesthetics of Employing Digital Sound Effects in Animated Films: سامر طه سالم
...Show More Authors

  When the digital technologies entered the world of cinema production, they boosted the ability of the cinematographic medium to implement various subjects with great accuracy, as the development included all the joints and stages of the cinematic film production whether it is a feature film or an animation. Therefore, the process of film manufacturing by the digital technologies reflects the spirit of the age and the development that humanity has attained. What motivated the researcher to determine the topic of the research, which combines between the sound effects and the animated films under the title (aesthetics of employing digital sound effects in animated films), is the work of the digital technologies. The researcher divide

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Aug 30 2018
Journal Name
Journal Of Engineering
Accuracy Assessment of Various Resolutions Digital Cameras For Close Range Photogrammetry Applications
...Show More Authors

Due to the great evolution in digital commercial cameras, several studies have addressed the using of such cameras in different civil and close-range applications such as 3D models generation. However, previous studies have not discussed a precise relationship between a camera resolution and the accuracy of the models generated based on images of this camera. Therefore the current study aims to evaluate the accuracy of the derived 3D buildings models captured by different resolution cameras. The digital photogrammetric methods were devoted to derive 3D models using the data of various resolution cameras and analyze their accuracies. This investigation involves selecting three different resolution cameras (low, medium and

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Thu Jun 15 2017
Journal Name
Journal Of Baghdad College Of Dentistry
Prevalence and localization of the posterior superior alveolar artery in relation to the floor of the maxillary sinus and alveolar crest among sample of Iraqis using computed tomography
...Show More Authors

Background: Posterior superior alveolar artery (PSAA) is branch of the maxillary artery. It usually supplies the lateral wall of the sinus and overlying membrane. Evaluation and awareness of the anatomy of maxillary sinus before surgery is crucial to avoid surgical complications. The aim of this study is to examine the prevalence, location of the (PSAA) in relation to the floor of the maxillary sinus and alveolar crest using computerized tomography (CT) scans. Materials and Methods: This study included 180 Iraqi subjects (99 males and 81 females) with age more than 16 years old. CT scans for (right and left) Maxillary sinuses were done for each patient. The information obtained was assessed in a coronal multi planar reconstructions images (

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Mar 01 2016
Journal Name
Al-academy
Digital Photo credibility and its reflection on the cognitive process of journalistic image of Viewers: زيـاد طـارق شـــاكر
...Show More Authors

Represent the current study and tagged (the credibility of digital image and its reflection on the process of cognitive picture releases) scientific effort is designed to detect realizing press releases and the extent affected the credibility of the digital image by selecting the relationship between digital photo and the extent of their credibility on the one hand and between the process of cognition and Press Photo of the hand Other than the consequent establishment researcher collects materials to serve the scientific research topic in three chaptersCombine the first one methodological framework for the search of the research problem and its significance and the desired objective be achieved together with the definition of the most im

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Jun 30 2023
Journal Name
Iraqi National Journal Of Nursing Specialties
Effectiveness of Cardiac Rehabilitation Instructional Program on Health-related Quality of Life for Patients Undergone Coronary Artery Bypass Graft Surgery
...Show More Authors

Objective(s): evaluation of effectiveness of cardiac rehabilitation instructional program on health-related quality of life and to find out the relationship between health-related quality of life and patient’s socio-demographic and clinical characteristics. 

Methodology: A descriptive study design was carried out from 8th August, 2022 to 10th January, 2023.

A non-probability purposive sample of (50) patients undergone coronary artery bypass graft surgery at Iraqi center for heart diseases using pre-experimental design. The data were collected by direct interview with sample using questionnaire composed of three parts: part (1) Socio-demographic and clinical ch

... Show More
View Publication Preview PDF
Crossref (5)
Crossref