Preferred Language
Articles
/
fhiLZ5UBVTCNdQwCbS0l
Pulse transmission time and amplitude of digital pulse wave determined by fingertip plethysmography as a surrogate marker of brachial artery flowmediated dilatation
...Show More Authors

Objectives: To assess the changes in blood vessel stiffness and digital pulse wave amplitude because of flowmediateddilatation, and to explore how these two variables change when endothelial dysfunction isexperimentally induced.Method: The experimental study was conducted at the departments of physiology at the College of Medicine,Mustansiriyah University, and the College of Medicine, Al-Iraqia University, Baghdad, Iraq, from October 14, 2021, toMay 31, 2022, and comprised healthy young males who were subjected to the flow-mediated dilatation techniqueon the left brachial artery. Pulse transit time and the amplitude of the digital pulse wave were measured duringreactive hyperaemia for 2.5 minutes from the left middle finger using a piezoelectric pressure sensor and asimultaneous Lead I electrocardiogram. Endothelial dysfunction (ED) was induced by oscillatory and retrogradeshear rates. The correlation between variables was calculated in Excel running on the Windows operating system.Results: There were 10 second-year medical students with mean age 22±0 years and mean body mass index25.7±4.8kg/m2. During reactive hyperaemia, pulse transit time was significantly increased by 3-5% in both normalendothelium and experimentally induced endothelial dysfunction relative to the pre-occluded artery, and thedifference was not significant (p>0.05). Digital pulse wave amplitude increased significantly in normal endotheliumrelative to the pre-occluded artery (p<0.05), but not in experimentally-induced endothelial dysfunction (p>0.05).Conclusion: The pulse transit time and digital pulse wave amplitudes of the photo plethysmography signal may beused to detect changes in vessel wall diameter and tone throughout the reactive hyperaemia process. Digital pulsewave amplitude was better able to detect experimentally-induced endothelial dysfunction, as assessed by the flowmediateddilatation protocol, than pulse transit time.Key Words: Hyperemia, Brachial Artery, Dilatation, Plethysmography, Electrocardiography, Pulse Wave,Endothelium, Running

Scopus Clarivate Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Sep 15 2021
Journal Name
Journal Of Baghdad College Of Dentistry
Diet and orthodontics- A review
...Show More Authors

During the course of fixed orthodontic therapy, patients should be instructed to eat specific food stuffs and beverages in order to maintain good health for the dentition and supporting structures and prevent frequent attachment debonding that prolong the treatment duration. After searching and collecting articles from 1930 till July 2021, the current review was prepared to emphasize various types of foods that should be taken during the course of fixed orthodontic therapy and to explain the effect of various food stuffs and beverages on the growth and development of craniofacial structures, tooth surfaces, root resorption, tooth movement, retention and stability after orthodontic treatment and the effect on the components of fixed ortho

... Show More
View Publication Preview PDF
Scopus (5)
Crossref (5)
Scopus Crossref
Publication Date
Fri Mar 01 2019
Journal Name
Iraqi Journal Of Physics
Optical and structural study for DLC thin films prepared by plasma jet
...Show More Authors

Diamond-like carbon (DLC) homogeneous thin films were deposited from cyclohexane (Ccyclohexane (Ccyclohexane (Ccyclohexane (C cyclohexane (Ccyclohexane (Ccyclohexane (C cyclohexane (Ccyclohexane (C 6H12 ) liquid by using a plasma jet system which operates with alternating high voltage 7.5 which operates with alternating high voltage 7.5which operates with alternating high voltage 7.5which operates with alternating high voltage 7.5 which operates with alternating high voltage 7.5which operates with alternating high voltage 7.5which operates with alternating high voltage 7.5 which operates with alternating high voltage 7.5which operates with alternating high voltage 7.5 which operates with alternating high voltage 7.5which operates with al

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Nov 02 2016
Journal Name
World Journal Of Pharmaceutical Research
HISTOGENESIS AND HISTOMORPHOMETRIC STUDY ON KIDNEY DISORDER BY LAMOTRIGINE IN POSTNATAL RAT
...Show More Authors

Background: Lamotrigine is a second generation Anti-epileptic drug; it is widely used for the treatment of epilepsy and bipolar disorder. Sufficient data is not available concerning its teratogenicity. Aim of the study: The study has been carried out to evaluate the effect of lamotrigine on Rat kidney development. Materials and Methods: The study was conducted on 10 pregnant Albino Rats (Rattus rattus) divided equally into two groups, control and experiment groups. Experiment group received lamotrigne 10mg/kg/day orally using naso-gastric tube from the first day of gestation until the first week after birth, while the control group received distilled water. Newborn kidneys were collected at day 7 postnatal and fixated in bouin’s solution,

... Show More
Publication Date
Mon Feb 04 2019
Journal Name
Journal Of The College Of Education For Women
The Recantation By The Al-Zaher People And Its Effects in Derivation
...Show More Authors

nouns , because deriving these names will lead to eternity which is impossible, and restrict the derivation only in agent nouns from their verbs, and the adjective names from their adjectives with the condition of truth in derivation.
The derivation of “Allah” names was denied due to a creed thoughts, because saying that “Allah” names is derived will not describe the eternal essence of “Allah”, and if it were derived this will make “Allah” is a Compound from his essence and Attributes.
The Al-Zaher people had recant the derivation of the agent nouns by preventing the derivation of “Allah” names because it will make “Allah” is a Compound from his essence and Attributes.
The Al-Zaher people had recant from

... Show More
View Publication Preview PDF
Publication Date
Tue Sep 21 2021
Journal Name
Jmerd
stress and strain analysis for the prosthetic hand design actuated by links
...Show More Authors

Prosthetic hands are compensatory devices for the hand amputees as a result of injury, various accidents or birth deformities, types of prosthetic hand vary depending on the mechanism they operate and how they perform. There are common types in use that are characterized by their complex mechanisms, which are difficult for the amputee to use or exclude use because of their high cost, therefore the aim of this research is to design an artificial hand that is suitable in terms of simplicity of use and low cost and similar to a natural hand with regard to dimensions and shape that operated in the mechanism of links. This research involves Stress and strain analysis of the prosthetic hand and its fingers that modelled from (Petg CR)

... Show More
View Publication Preview PDF
Publication Date
Tue Sep 01 2020
Journal Name
Iraqi Journal Of Physics
The magnetic switch manufacturing by using ferrofluid and ferrofluid doped copper nanoparticles
...Show More Authors

In this work, a magnetic switch was prepared using two typesof ferrofluid materials, the pure ferrofluid and ferrofluid doped with copper nanoparticles (10 nm). The critical magnetic field (Hc) and the state of magnetic saturation (Hs) were studied using three types of laser sources. The main parameters of the magnetic switch measured using pure ferrofluid and He-Ne Laser source were Hc(0.5 mv, 0.4 G), Hs (8.5 mv, 3 G). For the ferrofluid doped with copper nanoparticles were Hc (1 mv, 4 G), Hs (15 mv, 9.6 G), Using green semiconductor laser for the Pure ferrofluid were Hc (0.5 mv, 0.3 G) Hs (15 mv, 2.9 G). While the ferrofluid doped with copper nanoparticles were Hc (0.5 mv, 1 G), Hs (12 mv, 2.8 G) and by using the violet semiconductor l

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu May 28 2015
Journal Name
International Journal Of Recent Scientific Research
HYBRID MACHINES PET/CT SCANNERS BY USING 18F, 82SR AND 68GE RADIONUCLIDE
...Show More Authors

The increased use of hybrid PET /CT scanners combining detailed anatomical information along withfunctional data has benefits for both diagnostic and therapeutic purposes. This presented study is to makecomparison of cross sections to produce 18F , 82Sr and68Ge via different reactions with particle incident energy up to 60 MeV as a part of systematic studies on particle-induced activations on enriched natNe, natRb, natGa 18O,85Rb, and 69Ga targets, theoretical calculation of production yield, calculation of requiredtarget and suggestion of optimum reaction to produce: Fluorine-18 , Strontium-82 andGermanium-68 touse in Hybrid Machines PET/CT Scanners.

Preview PDF
Publication Date
Mon Jan 01 2024
Journal Name
Ieee Access
Enhancing Speed and Imperceptibility in Watermarking Systems by Leveraging Galois Field Tables
...Show More Authors

View Publication
Scopus Clarivate Crossref
Publication Date
Sat Jul 15 2023
Journal Name
Journal Of Aridland Agriculture
Estimating the infection severity and infection percentage by aphids on eggplant varieties
...Show More Authors

Finding a new source of resistance is important to reduce the use of synthetic pesticides, which can meet the global need of suppressing pollution. In this study, the resistance of eight eggplant cultivars to Aphis gossypii was evaluated. Results of the current study highlighted that the cultivar Long-Green has a very strong resistance after 14 days post infestation whereas Pearl-Round and White-Casper cultivars were susceptible. The rest of the tested cultivars (Green-oblong, Purple-panter, Paris, Ashbilia, and Barcelona) had mild resistance. Also, the study found significant differences between the infested and non-infested plants among the tested cultivars in the plant’s height, fresh-, and dry-weight. The susceptible cultivars

... Show More
View Publication
Scopus Crossref
Publication Date
Mon Jan 02 2012
Journal Name
Karbala Journal Of Medicine
Open Tibial Shaft Fractures Treated By Primary External Fixation And Bone Graft
...Show More Authors

Eprospective study undertaken between January 2007 and January 2011, 58 consecutive cases with compound tibial shaft fractures. All fractures were stabilized by external fixator device AO/ASIF type after failed the manipulation under anesthesia (MUA) to restore the osseous alignment. In 32 patients cancellous bone graft were used from the upper part of the tibia to enhance healing process, all these patients were followed for an average of 8–12 months. Our findings showed that stabilization of the fracture shaft tibia by external fixation with cancellous bone graft had significantly better result, than external fixation alone. We conclude that unilateral, uniplanar external fixation with early bone grafting from upper part of the tibia is

... Show More