Preferred Language
Articles
/
fhiLZ5UBVTCNdQwCbS0l
Pulse transmission time and amplitude of digital pulse wave determined by fingertip plethysmography as a surrogate marker of brachial artery flowmediated dilatation
...Show More Authors

Objectives: To assess the changes in blood vessel stiffness and digital pulse wave amplitude because of flowmediateddilatation, and to explore how these two variables change when endothelial dysfunction isexperimentally induced.Method: The experimental study was conducted at the departments of physiology at the College of Medicine,Mustansiriyah University, and the College of Medicine, Al-Iraqia University, Baghdad, Iraq, from October 14, 2021, toMay 31, 2022, and comprised healthy young males who were subjected to the flow-mediated dilatation techniqueon the left brachial artery. Pulse transit time and the amplitude of the digital pulse wave were measured duringreactive hyperaemia for 2.5 minutes from the left middle finger using a piezoelectric pressure sensor and asimultaneous Lead I electrocardiogram. Endothelial dysfunction (ED) was induced by oscillatory and retrogradeshear rates. The correlation between variables was calculated in Excel running on the Windows operating system.Results: There were 10 second-year medical students with mean age 22±0 years and mean body mass index25.7±4.8kg/m2. During reactive hyperaemia, pulse transit time was significantly increased by 3-5% in both normalendothelium and experimentally induced endothelial dysfunction relative to the pre-occluded artery, and thedifference was not significant (p>0.05). Digital pulse wave amplitude increased significantly in normal endotheliumrelative to the pre-occluded artery (p<0.05), but not in experimentally-induced endothelial dysfunction (p>0.05).Conclusion: The pulse transit time and digital pulse wave amplitudes of the photo plethysmography signal may beused to detect changes in vessel wall diameter and tone throughout the reactive hyperaemia process. Digital pulsewave amplitude was better able to detect experimentally-induced endothelial dysfunction, as assessed by the flowmediateddilatation protocol, than pulse transit time.Key Words: Hyperemia, Brachial Artery, Dilatation, Plethysmography, Electrocardiography, Pulse Wave,Endothelium, Running

Scopus Clarivate Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Feb 16 2016
Journal Name
The Iraqi Journal Of Agricultural Sciences
MEASURING VIBRATION AT TRACTOR PLATFORM , STEERING WHEEL AND SEAT EFFECTIVE AMPLITUDE TRANSMISSIBILITY FACTOR DURING OPERATION TILLAGE
...Show More Authors

Field experiment conducted to measure vibrations on three axes longitudinal X, lateral Y and vertical Z on steering wheel, platform tractor and vertical vibration in seat tractor and seat effective amplitude transmissibility (SEAT) factor during operation tillage in silt clay loam soil with depth 18 cm in Baghdad. Split – split plot design under randomized complete block design with three replications least significant design 5 % used. Three factor were used in this experiment included two types of plows included chisel and disc plows which represented main plot, three tires inflation pressure was second factor included 1.1 ,1.8 and 2.7 bar, and three forward speeds of the tillage was third factor included 2.35 , 4.25 and 6.50 km/hr. Resu

... Show More
Publication Date
Fri Sep 30 2022
Journal Name
Journal Of Economics And Administrative Sciences
The impact of digital leadership in the effectiveness of organizational crisis management by mediating strategic vigilance
...Show More Authors

The current research aims to verify the impact of digital leadership as an independent variable, in the effectiveness of crisis management as a response  variable through centralizing strategic vigilance in the faculties of the University of Baghdad and its departments, and to investigate the level of interest of its leaders and subordinates in research variables, as well as coming up with recommendations that contribute to strengthening the practices of the three variables. In the university under study, and based on the researcher’s  interest  to diagnose the influence relationship between the variables, because of their importance in the university’s headquarters and its members on the one hand, and its refl

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Thu Jun 15 2023
Journal Name
Romanian Neurosurgery
A giant A4-A5 distal anterior cerebral artery aneurysm treated with microsurgical clip reconstruction
...Show More Authors

Background. Aneurysms of the distal anterior cerebral artery (DACA) are uncommon; they often form near the pericallosal-callosomarginal junction and are typically small. To our knowledge, giant DACA aneurysms developing from the more distant parts of the anterior cerebral artery (ACA), A4-5, have been described only once in the literature. Case description. A 66-year-old gentleman reported with a brief loss of consciousness followed by weakness in his right lower leg. The patient was admitted with a Glasgow Coma Score (GCS) of 15. A computed tomography (CT) scan of the head revealed a left hyperdense mass in the frontal parasagittal supracallosal region. Contrast MRI revealed a heterogeneously enhancing mass measuring 35x30x25 mm. C

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jan 25 2015
Journal Name
International Journal Of Applied Mathematical Research
Exact solutions to linear and nonlinear wave and diffusion equations
...Show More Authors

View Publication
Crossref (3)
Crossref
Publication Date
Mon Mar 08 2021
Journal Name
Baghdad Science Journal
A study the electrical properties of a Se:2.5%as thin films prepared by thermal cvaporation
...Show More Authors

thin films of se:2.5% as were deposited on a glass substates by thermal coevaporation techniqi=ue under high vacuum at different thikness

View Publication Preview PDF
Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Indian Journal Of Forensic Medicine And Toxicology
Color stability of different aesthetic resin composite materials: A digital image analysis
...Show More Authors

Scopus (2)
Scopus
Publication Date
Sat Jan 25 2020
Journal Name
Indian Journal Of Forensic Medicine &amp; Toxicology
Color Stability of Different Aesthetic Resin Composite Materials: A Digital Image Analysis
...Show More Authors

View Publication
Crossref (1)
Crossref
Publication Date
Fri Dec 01 2023
Journal Name
Baghdad Science Journal
Determining ACE-2 Level and Some Relevant Biochemical Parameters and studying the effect of Gender in Iraqi Diabetic Patients with Glomeruli and Renal Tubules Fibrosis as Early Prediction Marker
...Show More Authors

     Diabetic kidney disease is an illness of the glomerulus that interferes with the glomerular filtration barrier (GFB), which is worked to enable kidney to selective purification of water and solutes in addition to limiting the movement of large macromolecules such as albumin. In the glomerular endothelium, mesangial cells, foot cells, and the brush border of the proximal tubules, ACE-2 is expressed and that the kidneys represent the highest-expressing region of this enzyme. Thus, the current study aimed to evaluate ACE-2 level in this case compared to healthy condition. The study Conducted with 120 male and female ranging in age (30-65) years old. Ninety patients with type 2 diabetes subdivided into three groups on the basis of A

... Show More
View Publication Preview PDF
Scopus (5)
Scopus Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Journal Of Mechanical Engineering Research And Developments
Real-time control of robotic hand by human hand at low cost
...Show More Authors

Scopus (4)
Scopus
Publication Date
Sat Aug 03 2019
Journal Name
Current Research In Microbiology And Biotechnology
Seropositivity of Helicobacter pylori among Iraqi patients with Atherosclerosis and coronary artery disease
...Show More Authors

The present study evaluated the anti- Helicobacter pylori IgG, IgA and the role of virulence factor of H. pylori Vacuolating associated cytotoxin gene (Vac A) as a risk factors for CAD. The levels of serum IgG and IgA was done by indirect immunofluorescent (IIF) whereas Vac A measured by enzyme linked immunosorbent assay (ELISA). Ibn Al-Bitar specialist center for cardiac surgery laboratory and Ministry of Health/ Baghdad/ Iraq, between May and October 2018. Seventy Iraqi patients with CAD were enrolled in this study, their ages ranged between 40-84 years ; and 20 individuals as a control group which was divided into 2 subgroups: 10 apparently healthy volunteers (negative control) and the other subgroup contained 10 with normal coronary art

... Show More